Sanyo SAP–CR184G Technical & Service Manual

Category
Split-system air conditioners
Type
Technical & Service Manual
TECHNICAL & SERVICE MANUAL
SAPKR184GJH + SAPCR184GH
SAPKR224GJH + SAPCR224GH
FILE NO.
REFERENCE NO. SM700629
Indoor Unit
Outdoor Unit
SPLIT SYSTEM AIR CONDITIONER
A
I
R
C
O
N
DITIONER
SAPKR184GJH
SAPKR224GJH
SAPCR184GH
SAPCR224GH
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention when
servicing the unit.
Indoor Model No. Product Code No.
SAPKR184GJH 1 852 094 03
SAPKR224GJH 1 852 094 02
Outdoor Model No. Product Code No.
SAPCR184GH 1 852 094 07
SAPCR224GH 1 852 094 06
Destination: Australia (50Hz)
General area (50Hz)
2
Important!
Please Read Before Starting
This air conditioning system meets strict safety and
operating standards. As the installer or service person,
it is an important part of your job to install or service the
system so it operates safely and efficiently.
For safe installation and trouble-free operation, you
must:
Carefully read this instruction booklet before
beginning.
Follow each installation or repair step exactly as
shown.
Observe all local, state, and national electrical codes.
Pay close attention to all warning and caution notices
given in this manual.
This symbol refers to a hazard or
unsafe practice which can result
in severe personal injury or
death.
This symbol refers to a hazard or
unsafe practice which can result
in personal injury or product or
property damage.
If Necessary, Get Help
These instructions are all you need for most installation
sites and maintenance conditions. If you require help
for a special problem, contact our sales/service outlet
or your certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this document.
Special Precautions
When Wiring
ELECTRICAL SHOCK CAN CAUSE
SEVERE PERSONAL INJURY OR
DEATH. ONLY A QUALIFIED,
EXPERIENCED ELECTRICIAN SHOULD
ATTEMPT TO WIRE THIS SYSTEM.
Do not supply power to the unit until all wiring and
tubing are completed or reconnected and checked.
Highly dangerous electrical voltages are used in this
system. Carefully refer to the wiring diagram and
these instructions when wiring. Improper connections
and inadequate grounding can cause accidental
injury or death.
Ground the unit following local electrical codes.
Connect all wiring tightly. Loose wiring may cause
overheating at connection points and a possible fire
hazard.
WARNING
CAUTION
WARNING
When Transporting
Be careful when picking up and moving the indoor and
outdoor units. Get a partner to help, and bend your
knees when lifting to reduce strain on your back. Sharp
edges or thin aluminum fins on the air conditioner can
cut your fingers.
When Installing…
…In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the
units weight. It may be necessary to construct a strong
wood or metal frame to provide added support.
…In a Room
Properly insulate any tubing run inside a room to
prevent “sweating” that can cause dripping and water
damage to walls and floors.
…In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to
provide a solid, level foundation for the outdoor unit.
This prevents water damage and abnormal vibration.
…In an Area with High Winds
Securely anchor the outdoor unit down with bolts and a
metal frame. Provide a suitable air baffle.
…In a Snowy Area (for Heat Pump-type Systems)
Install the outdoor unit on a raised platform that is
higher than drifting snow. Provide snow vents.
When Connecting Refrigerant Tubing
Use the flare method for connecting tubing.
Apply refrigerant lubricant to the matching surfaces
of the flare and union tubes before connecting them,
then tighten the nut with a torque wrench for a leak-
free connection.
Check carefully for leaks before starting the test run.
When Servicing
Turn the power off at the main power box (mains)
before opening the unit to check or repair electrical
parts and wiring.
Keep your fingers and clothing away from any
moving parts.
Clean up the site after you finish, remembering to
check that no metal scraps or bits of wiring have
been left inside the unit being serviced.
Others
Ventilate any enclosed areas when installing or
testing the refrigeration system. Escaped refrigerant
gas, on contact with fire or heat, can produce
dangerously toxic gas.
Confirm upon completing installation that no
refrigerant gas is leaking. If escaped gas comes in
contact with a stove, gas water heater, electric room
heater or other heat source, it can produce
dangerously toxic gas.
CAUTION
Table of Contents
Page
1. OPERATING RANGE .............................................................................................................................. 5
2. SPECIFICATIONS
2-1. Unit Specifications.......................................................................................................................... 6
2-2. Major Component Specifications.................................................................................................... 8
2-3. Other Component Specifications.................................................................................................... 12
3. DIMENSIONAL DATA.............................................................................................................................. 13
4. REFRIGERANT FLOW DIAGRAM ......................................................................................................... 15
5. PERFORMANCE DATA
5-1. Performance charts ....................................................................................................................... 16
5-2. Air Throw Distance Chart .............................................................................................................. 18
5-3. Cooling Capacity ........................................................................................................................... 20
5-4. Heating Capacity ........................................................................................................................... 22
6. ELECTRICAL DATA
6-1. Electrical Characteristics................................................................................................................ 23
6-2. Electric Wiring Diagrams................................................................................................................ 25
7. INSTALLATION INSTRUCTIONS
7-1. Installation Site Selection ............................................................................................................... 27
7-2. Remote Control Unit Installation Position....................................................................................... 29
7-3. Recommended Wire Length and Diameter ................................................................................... 30
7-4. How to Test Run the Air Conditioner ............................................................................................. 31
7-5. Remove the grille to Install the Indoor Unit .................................................................................... 32
8. FUNCTION
8-1. Room Temperature Control ........................................................................................................... 33
8-2. Dry Operation ................................................................................................................................ 35
8-3. Automatic Switching between Cooling and Heating ...................................................................... 36
8-4. Freeze Prevention ......................................................................................................................... 37
8-5. Cold Draft Prevention .................................................................................................................... 38
8-6. Overload Prevention ...................................................................................................................... 39
8-7. Automatic fan speed ...................................................................................................................... 40
8-8. Defrosting Operation ...................................................................................................................... 41
8-9. Outdoor Fan Speed Control .......................................................................................................... 42
9. TROUBLESHOOTING
9-1. Check before and after troubleshooting ........................................................................................ 43
9-2. Air conditioner does not operate .................................................................................................... 44
9-3. Some part of air conditioner does not operate ..............................................................................48
9-4. Air conditioner operates, but abnormalities are observed ............................................................. 50
10. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING THE UNIT
10-1. Characteristics of new refrigerant R410A....................................................................................... 53
10-2. Checklist before serving................................................................................................................. 53
10-3. Tools specifically for R410A........................................................................................................... 55
10-4. Tubing installation procedures........................................................................................................ 55
10-5. In case of compressor malfunction................................................................................................. 56
10-6. In case refrigerant is leaking........................................................................................................... 58
10-7. Charging additional refrigerant....................................................................................................... 59
10-8. Retro-fitting existing systems.......................................................................................................... 59
3
11. CHECKING ELECTRICAL COMPONENTS
11-1. Measurement of Insulation Resistance .......................................................................................... 60
11-2. Checking Continuity of Fuse on PCB Ass'y.................................................................................... 61
11-3. Checking Motor Capacitor ............................................................................................................. 61
12. MAINTENANCE
12-1. Address Setting of the Remote Control Unit .................................................................................. 62
.................................................................................................................................................. 63
APPENDIX
4
5
1. OPERATING RANGE
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 32°C D.B. / 23°C W.B. 43°C D.B.
Minimum 19°C D.B. / 14°C W.B. 19°C D.B.
Heating
Maximum 27°C D.B. 24°C D.B. / 18°C W.B.
Minimum 16°C D.B. 8°C D.B. / –9°C W.B.
6
2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit SAPKR184GJH
Outdoor Unit SAPCR184GH
Power Source 220–240V Single phase 50Hz
Voltage rating 220 / 230 / 240 V
Performance Cooling Heating
Capacity kW 5.15 / 5.15 / 5.30 5.70 / 5.70 / 5.70
BTU/h 17,600 / 17,600 / 18,100 19,400 / 19,400 / 19,400
Air circulation (High)
m
3
/h
890 890
Moisture removal (High) Liters/h 2.3
Electrical Rating Cooling Heating
Available voltage range V 198 ~ 264
Running amperes A 7.4 / 7.1 / 7.1 7.3 / 7.0 / 6.7
Power input W 1,600 / 1,600 / 1,650 1,580 / 1,580 / 1,580
Power factor % 98 / 98 / 97 98 / 98 / 98
C.O.P. W/W 3.22 / 3.22 / 3.21 3.61 / 3.61 / 3.61
Compressor locked rotor amperes A 28 28
Features
Controls / Temperature control Microprocessor / I.C. thermistor
Control unit Wireless remote controller
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto (Hi/Lo)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R410A / 1,600
Refrigerant control Capillary tube
Operation sound Indoor: Hi/Me/Lo/Qt* dB-A 42 / 39 / 35 / 32 41 / 38 / 34 / 32
(*Qt=Quiet mode at Lo) Outdoor: Hi dB-A 55 56
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 12.7(1/2)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 298 670
Width mm 1,065 880
Depth mm 218 285
Package dimensions Height mm 299 740
Width mm 1,140 1,022
Depth mm 379 400
Weight Net kg 12.0 48.0
Shipping kg 15.0 52.0
Shipping volume
m
3
0.129 0.303
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
7
Indoor Unit SAPKR224GJH
Outdoor Unit SAPCR224GH
Power Source 220–240V Single phase 50Hz
Voltage rating 220 / 230 / 240 V
Performance Cooling Heating
Capacity kW 6.40 / 6.40 / 6.40 7.20 / 7.20 / 7.20
BTU/h 21,800 / 21,800 / 21,800 24,600 / 24,600 / 24,600
Air circulation (High)
m
3
/h
980 980
Moisture removal (High) Liters/h 3.3
Electrical Rating Cooling Heating
Available voltage range V 198 ~ 264
Running amperes A 10.4 / 10.0 / 9.6 10.3 / 9.8 / 9.4
Power input W 2,275 / 2,275 / 2,280 2,240 / 2,240 / 2,240
Power factor % 99 / 99 / 99 99 / 99 / 99
C.O.P. W/W 2.81 / 2.81 / 2.81 3.21 / 3.21 / 3.21
Compressor locked rotor amperes A 49 49
Features
Controls / Temperature control Microprocessor / I.C. thermister
Control unit Wireless remote controller
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto (Hi/Lo)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R410A / 1,850
Refrigerant control Capillary tube
Operation sound Indoor: Hi/Me/Lo/Qt* dB-A 45 / 41 / 37 / 32 44 / 40 / 36 / 32
(*Qt=Quiet mode at Lo) Outdoor: Hi dB-A 57 58
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 10
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 15.88(5/8)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 298 670
Width mm 1,065 880
Depth mm 218 285
Package dimensions Height mm 299 740
Width mm 1,140 1,022
Depth mm 379 400
Weight Net kg 12.0 56.0
Shipping kg 15.0 60.0
Shipping volume
m
3
0.129 0.303
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
8
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit SAPKR184GJH
Controller PCB
Part No. CB-KR184EH (POW-KR184GJH)
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-4HPIS4E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø94 / L845
Fan motor model ... Q'ty DC Motor SIC-39CVL-D847-2 ... 1
No. of poles ... Rough measure rpm (Cool / Heat) 8 ... 1,200 / 1,200
Nominal output W 30
Coil resistance (Ambient temp. 20°C) ——
——
——
——
——
Safety devices Type Internal controller
Over-current protection Yes
Overheat protection Yes
Run capacitor (on controller PCB) µF
VAC
Flap Motor
Type Stepping motor
Model MP24Z3-12V
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) Each pair of terminals : 400 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.3
Face area
m
2
0.285
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
9
Indoor Unit SAPKR224GJH
Controller PCB
Part No. CB-KR224EH (POW-KR184GJH)
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-4HPIS4E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø94 / L845
Fan motor model ... Q'ty DC Motor SIC-39CVL-D847-2 ... 1
No. of poles ... Rough measure rpm (Cool / Heat) 8 ... 1,300 / 1,300
Nominal output W 30
Coil resistance (Ambient temp. 20°C) ——
——
——
——
——
Safety devices Type Internal controller
Over-current protection Yes
Overheat protection Yes
Run capacitor (on controller PCB) µF
VAC
Flap Motor
Type Stepping motor
Model MP24Z3-12V
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) Each pair of terminals : 400 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.3
Face area
m
2
0.285
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
10
2-2-2. Outdoor Unit
Outdoor Unit SAPCR184GH
Controller PCB
Compressor
Type Rotary (Hermetic)
Compressor model 5KS205DAJ21 85204526321
Nominal output W 1,500
Compressor oil ... Amount cc FV50S ... 670
Coil resistance (Ambient temp. 20°C) C–R : 1.780
C–S : 2.175
Safety devices Type Internal protector
Overload relay
Operating temp. Open °C Automatic opening
Close °C Automatic reclosing
Operating amp.(Ambient temp. 25°C)
Run capacitor µF 50
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø420
Fan motor model ... Q'ty AC motor KFG6S-51E5P ... 1
No. of poles ... Rough measure rpm (Cool / Heat) 6 ... 870 / 850
Nominal output W 50
Coil resistance (Ambient temp. 20°C) WHT-BRN : 63.60
WHT-YEL : 58.48
YEL-PNK : 23.36
Safety devices Type Thermal protector
Operating temp. Open °C 130±8
Close Automatic reclosing
Run capacitor µF 4
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.2
Face area
m
2
0.510
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
11
Outdoor Unit SAPCR224GH
Controller PCB
Compressor
Type Rotary (Hermetic)
Compressor model 5JS270DAA21 85204526322
Nominal output W 1,800
Compressor oil ... Amount cc FV50S ... 1,130
Coil resistance (Ambient temp. 20°C) C–R : 1.166
C–S : 1.534
Safety devices Type Internal protector
Overload relay
Operating temp. Open °C Automatic opening
Close °C Automatic reclosing
Operating amp.(Ambient temp. 25°C)
Run capacitor µF 60
VAC 400
Crank case heater
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø420
Fan motor model ... Q'ty AC motor KFG4S-51C5PB ... 1
No. of poles ... Rough measure rpm (Cool / Heat) 4 ... 980 / 950
Nominal output W 50
Coil resistance (Ambient temp. 20°C) WHT-BRN : 53.83
WHT-YEL : 36.32
YEL-PNK : 15.14
Safety devices Type Thermal protector
Operating temp. Open °C 130±8
Close Automatic reclosing
Run capacitor µF 5
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.2
Face area
m
2
0.510
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-3. Other Component Specifications
12
4-way Valve (Solenoid coil) SHF-7H-34U
Rating AC 220-240 V , 50 / 60 Hz
Refrigerant R22, R407C, R410A
Thermostat (Fan Speed Control 23S) MQT5S
Switching temp. °C
high LOW 28.5°C ± 1.5
low HIGH 31.5°C ± 2
Contact rating AC 220V, 3A
< Only for 224 class >
Magnetic Contactor CLK–25J2
Coil rating 50Hz 220 ~ 240V
Coil resistance k(at 20°C) 2.0
< Only for 184 class >
Power Relay (PR) EL1U
Coil rating AC 200240V, 50/60Hz
Contact rating AC 277V, 30A
Outdoor Unit SAPCR184GH
SAPCR224GH
Thermistor (Coil / Room sensor) PBM-D41E-S1 (Coil / Room)
Resistance k Coil 0°C 15.0 ± 5% / Room 25°C 5.0 ± 4%
Indoor Unit SAPKR184GJH
SAPKR224GJH
13
3. DIMENSIONAL DATA
Indoor Unit SAPKR184GJH
SAPKR224GJH
(ø80)
49
5
1055
5
298
1065
50
60 100.5
1055
50
760
(3)218
475 403
60
49 24.5
402.5
95
450
95
212.5
117.5 117.5
1065
298
45
Drain hose ø18
Narrow tube
ø6.35(1/4")
90.5
90.5
307.5450307.5
95
45
95
202.4 202.4
(ø80)
196
46.5
27.4
70
32
133.8
52 23
Wide tube
ø12.70(1/2") 184
ø15.88(5/8") 224
Unit : mm
14
Outdoor Unit SAPCR184GH
SAPCR224GH
293
608
880 80
136
12
36
334
310
285
ID:ø
18
2-ID:ø
23.6
670
18
55111
166
2
145
AIR DISCHARGE
AIR INTAKE
AIR INTAKE
Narrow tube service valve
ø6.35
(
1/4"
)
Wide tube service valve
ø12.70(1/2") 184
ø15.88(5/8") 224
unit:m
Unit : mm
15
4. REFRIGERANT FLOW DIAGRAM
Insulation of Refrigerant Tubing
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
IMPORTANT
CAUTION
Wide tube
Thickness:
Min. 8 mm
Insulation
Narrow tube
Thickness:
Min. 8 mm
4-way
valve
Accumulator
Wide tube
service
valve
Wide tube
O.D.
ø12.7 mm
(1/2 ")
18 class
O.D.
ø15.88 mm
(5/8 ")
22 class
Compressor
Narrow
tube
service
valve
Narrow tube
O.D.
ø6.35 mm
(1/4")
Heat exchanger
Cooling cycle
Heating cycle
Indoor unit Outdoor unit
Heat exchanger
Muffler
Capillary tubes
(both for heating
and cooling)
Capillary tube
(for heating)
Check valve
or
Strainer
Indoor Unit SAPKR184GJH
SAPKR224GJH
Outdoor Unit SAPCR184GH
SAPCR224GH
5. PERFORMANCE DATA
5-1. Performance charts
16
Indoor inlet air
D.B. temp. (°C)
Indoor inlet air
D.B. temp. (°C)
Outdoor inlet air D.B. temp. (°C)
25 30 35 40 45 50
Low pressure at wide tube serveice valve MPa
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
1.8
Outdoor inlet air D.B. temp. (
°C)
–5 0 5 10 15 20 25
High pressure at wide tube serveice valve MPa
4.0
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
< Cooling Characteristics > < Heating Characteristics >
32
27
21
27
20
15
Indoor inlet air
D.B. temp. (°C)
Outdoor
fan speed
HighLow
Indoor inlet air
D.B. temp. (°C)
12
11
10
9
8
7
6
5
4
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
13
11
10
9
8
7
6
5
4
–5 0 5 10 15 20
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
25
12
15
27
20
15
32
27
21
Outdoor
fan speed
HighLow
Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high in
heating mode. (Refer to “8-6 Overload prevention”)
...... Points of Rating condition
Black dots in above charts indicate the following rating conditions.
Cooling: Indoor air temperature 27°C D.B./19°C W.B. Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 35°C D.B./24°C W.B. Outdoor air temperature 7°C D.B./6°C W.B.
NOTE
Indoor Unit SAPKR184GJH
Outdoor Unit SAPCR184GH
17
Indoor inlet air
D.B. temp. (°C)
Indoor inlet air
D.B. temp. (°C)
Outdoor inlet air D.B. temp. (°C)
25 30 35 40 45 50
Low pressure at wide tube serveice valve MPa
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
1.8
Outdoor inlet air D.B. temp. (
°C)
–5 0 5 10 15 20 25
High pressure at wide tube serveice valve MPa
4.0
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
< Cooling Characteristics > < Heating Characteristics >
32
27
21
27
20
15
Indoor inlet air
D.B. temp. (°C)
Outdoor
fan speed
HighLow
Indoor inlet air
D.B. temp. (°C)
15
14
13
12
11
10
9
8
7
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
16
27
20
15
14
13
12
11
10
9
8
7
–5 0 5 10 15 20
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
25
15
16
32
27
21
Outdoor
fan speed
HighLow
Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches extremely high in
heating mode. (Refer to “8-6 Overload prevention”)
...... Points of Rating condition
Black dots in above charts indicate the following rating conditions.
Cooling: Indoor air temperature 27°C D.B./19°C W.B. Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 35°C D.B./24°C W.B. Outdoor air temperature 7°C D.B./6°C W.B.
NOTE
Indoor Unit SAPKR224GJH
Outdoor Unit SAPCR224GH
5-2. Air Throw Distance Chart
Horizontal distance (m)
Axis air velocity (m/s)
Vertical distance (m)
Room air temp. : 20°C
Fan speed : High
Heating
Horizontal distance (m)
Axis air velocity (m/s)
Vertical distance (m)
Room air temp. : 27°C
Fan speed : High
Cooling
0
1
2
3
4
0123456789
: Flap angle 0° , : Axis air velocity 0°
: Flap angle 30°, : Axis air velocity 30°
0
1
2
3
4
0123456789
: Flap angle 45° , : Axis air velocity 45°
: Flap angle 60° , : Axis air velocity 60°
18
Indoor Unit SAPKR184GJH
Horizontal distance (m)
Axis air velocity (m/s)
Vertical distance (m)
Room air temp. : 20°C
Fan speed : High
Heating
Horizontal distance (m)
Axis air velocity (m/s)
Vertical distance (m)
Room air temp. : 27°C
Fan speed : High
Cooling
0
1
2
3
4
0123456789
: Flap angle 0° , : Axis air velocity 0°
: Flap angle 30°, : Axis air velocity 30°
0
1
2
3
4
0123456789
: Flap angle 45° , : Axis air velocity 45°
: Flap angle 60° , : Axis air velocity 60°
19
Indoor Unit SAPKR224GJH
20
5-3. Cooling Capacity
Indoor Unit SAPKR184GJH
Outdoor Unit SAPCR184GH
240V Single Phase 50Hz
RATING CAPACITY 5.30 kW
AIR FLOW RATE 890
m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 30 35 40 43
TC 4.88 4.64 4.36 4.02
CM 1.32 1.41 1.50 1.58
21 SHC 3.43 3.31 3.17 3.01
15 23 SHC 3.88 3.76 3.63 3.46
25 SHC 4.33 4.22 4.08 3.92
27 SHC 4.78 4.64 4.36 4.02
29 SHC 4.88 4.64 4.36 4.02
31 SHC 4.88 4.64 4.36 4.02
TC 5.23 4.98 4.68 4.31
CM 1.35 1.45 1.54 1.62
21 SHC 2.96 2.85 2.71 2.55
17 23 SHC 3.41 3.30 3.16 3.00
25 SHC 3.87 3.75 3.62 3.45
27 SHC 4.32 4.20 4.07 3.90
29 SHC 4.77 4.66 4.52 4.31
31 SHC 5.23 4.98 4.68 4.31
TC 5.57 # 5.30 4.98 4.58
CM 1.40 1.50 1.59 1.67
21 SHC 2.48 2.36 2.23 2.06
19 23 SHC 2.93 2.81 2.68 2.52
25 SHC 3.38 3.27 3.13 2.97
27 SHC 3.83 3.72 3.59 3.42
29 SHC 4.29 4.17 4.04 3.88
31 SHC 4.74 4.63 4.49 4.33
TC 5.90 5.62 5.28 4.86
CM 1.43 1.54 1.63 1.72
23 SHC 2.44 2.33 2.19 2.03
21 25 SHC 2.89 2.78 2.65 2.49
27 SHC 3.34 3.23 3.10 2.94
29 SHC 3.80 3.69 3.55 3.39
31 SHC 4.25 4.14 4.01 3.85
TC 6.25 5.90 5.52 5.14
CM 1.47 1.58 1.68 1.77
23 25 SHC 2.37 2.24 2.11 1.97
27 SHC 2.82 2.70 2.56 2.43
29 SHC 3.28 3.15 3.01 2.88
31 SHC 3.73 3.60 3.47 3.33
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Sanyo SAP–CR184G Technical & Service Manual

Category
Split-system air conditioners
Type
Technical & Service Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI