Data creazione 10/09/03 DS03I009GB--00 Pagina 2 di 59
SUMMARY
CLIVET TALK LOCAL INTERFACE................................................................................................................. 3
DESCRIPTION OF THE BUTTONS ................................................................................................................................4
DESCRIPTION OF THE MAIN SCREEN.........................................................................................................................5
SYSTEM COMPOSITION.................................................................................................................................. 6
CENTRAL MODULE CLIVETTALK.LOCAL.M1...............................................................................................................6
DESCRIPTION OF THE JUMPERS.............................................................................................................................7
I/O CLIVETTALK.LOCAL.M1 .......................................................................................................................................7
EVAPORATOR MODULE CLIVETTALK.LOCAL.EX1.....................................................................................................9
DESCRIPTION OF THE JUMPERS.............................................................................................................................9
I/O CLIVETTALK.LOCAL.EX1....................................................................................................................................10
TANDEM COMPRESSOR MODULE CLIVETTALK.LOCAL.C2....................................................................................11
TRIO COMPRESSOR MODULE CLIVETTALK.LOCAL.C3...........................................................................................11
DESCRIPTION OF THE JUMPERS...........................................................................................................................11
CLIVETTALK.LOCAL.C2 AND CLIVETTALK.LOCAL.C3 ..........................................................................................12
INITIALISING THE MODULES ....................................................................................................................... 13
BASIC RULES FOR CONFIGURATION........................................................................................................................13
SETTING THE HARDWARE ADDRESS....................................................................................................................13
SETTING THE SOFTWARE ADDRESS....................................................................................................................14
SETTING THE HARDWARE ADDRESS OF THE CENTRAL MODULE....................................................................15
SETTING THE HARDWARE ADDRESS OF THE EVAPORATOR MODULE ...........................................................15
SETTING THE HARDWARE ADDRESS OF THE TRIO AND TANDEM MODULES.................................................15
TABLE FOR SETTING THE HARDWARE ADDRESS...............................................................................................16
LOCAL INTERFACE ADDRESS .................................................................................................................... 17
REMOTE INTERFACE ADDRESS................................................................................................................................17
CONFIGURATION EXAMPLE ........................................................................................................................ 18
SETTING THE HARDWARE ADDRESS.......................................................................................................................18
SETTING THE SOFTWARE ADDRESS........................................................................................................................19
PARAMETER MENU TREE............................................................................................................................ 20
OPERATING STATUS MENU TREE.............................................................................................................................39
GENERAL UNIT STATUS MENU..................................................................................................................................40
LIST OF ALARMS........................................................................................................................................... 42
CENTRAL MODULE ALARMS......................................................................................................................................42
COMPRESSOR MODULE ALARMS.............................................................................................................................43
EVAPORATOR MODULE ALARMS..............................................................................................................................44
OPERATION OF THE TEMPERATURE CONTROLLER............................................................................... 45
COOLING ......................................................................................................................................................................45
DETERMINING THE TEMPERATURE DIFFERENCE FOR EACH COMPRESSOR................................................45
FREECOOLING .........................................................................................................................................................46
HEATING.......................................................................................................................................................................51
DETERMINING THE TEMPERATURE DIFFERENCE FOR EACH COMPRESSOR................................................51
STEP ACTIVATION – SCAN TIMES .............................................................................................................. 52
STEP DEACTIVATION..................................................................................................................................................52
COMPENSATION............................................................................................................................................ 52
SET POINT CORRECTION IN COOLING ...................................................................................................... 53
SET POINT CORRECTION IN HEATING....................................................................................................... 54
SECOND SET POINT FROM DIGITAL INPUT............................................................................................... 55
DEMAND LIMIT............................................................................................................................................... 56
MAINTENANCE SET POINT .......................................................................................................................... 58
RESOURCE MANAGEMENT ALGORITHM ..................................................................................................59
BALANCING OF THE CAPACITY DELIVERED............................................................................................................59