EMS FireCell Radio Network Communicator for Taktis Quick start guide

Type
Quick start guide
Radio Network Communicator
FC-TAK-438
POWER
NETWORK FAULT
FAULT
POWER
FAU LT
SYSTEM
FAULT
Radio Hub
Taktis
Control Panel
230V AC
Radio Network
Communicator
POWER
FAU LT
SYSTEM
FAULT
Radio Hub
Taktis
Control Panel
230V AC
Radio Network Communicator
FC-TAK-438
POWER
NETWORK FAULT
FAULT
Radio Network
Communicator
RNC For Taktis Quick Start Guide Iss 2 - MK282 AJM
www.emsgroup.co.uk
QUICK START GUIDE
RADIO NETWORK COMMUNICATOR (RNC)
For Taktis®
FC-TAK-438
Step 1 Identify RNC Locations:
If a radio survey has already been carried out, the survey will detail the recommended
location of the Radio Network Communicators (RNCs) and also any aerial positions if
required.
600mm away from metal*
*300mm is a worst case
minimum requirement
2m away
from other
electrical
equipment
2m away
from other
electrical
equipment
2m away
from other
electrical
equipment
RNC
The recommended distance between metal objects from the aerial is 600mm. The
recommended distance to any other electrical equipment is 2m.
RNC
POWER
FAULT
SYSTEM
FAULT
2m
minimum
distance
Plastic conduit should
be used. Panel earth
faults will be shown if
metal conduit is used.
Never site RNC
within 2m of the
panel or Radio
Hub.
Control Panel Control Panel
POWER
FAULT
SYSTEM
FAULT
©2018 EMS Ltd. All rights reserved Page 2 of 4 Mk282 Iss 2 13/09/2018 AJM
NETWORK
FAU LT
FAU LT
POWER
RESET
UP
ENTER
DOWN
BACK
NETWORK
FAU LT
FAU LT
POWER
RESET
UP
ENTER
DOWN
BACK
NETWORK
FAU LT
FAU LT
POWER
RESET
UP
ENTER
DOWN
BACK
Step 2 Identify Cable Entry Location:
Open the unit to show the inner PCB. The cable entries can now be made. See entry
points below:
NO CABLE
ACCESS AT
TOP OF UNIT
ALL CABLES TO BE ROUTED NEATLY AT THE BOTTOM OF THE BOX, AND NOT OVER THE PCB BOARD
Step 3 Fix The RNC To The wall:
The unit can now be xed to the wall. The RNCs xing positions are as below:
Fixing Position 1
Fixing Position 2
Fixing Position 3
Fixing Position 4
Step 4 RNC To Control Panel Wiring:
The cable must be passed through the entry points provided. Connections are
detailed below:
Please Note: Care must be taken to ensure that connections are made correctly
before applying power to the unit. Damage may occur if cables are incorrectly
connected.
RS485 BUS & POWER CONNECTIONS
RS485 OUT
RS485 OUT
RS485 IN
RS485 IN
POWER IN
POWER IN
NETWORK IN
NETWORK IN
NETWORK OUT
NETWORK OUT
AUX 24V
AUX 24V
+
-
+
-
+
-
+
-
+
-
+
-
TAKTIS CONTROL
PANEL
REMOTE NETWORK
COMMUNICATOR
AUX
24V
-
+
OUT
IN
+
- + -
NETWORK
Taktis Control Panel
NO
Fault input / output
for remote fault
monitoring / remote
PSU (optional)
©2018 EMS Ltd. All rights reserved Page 3 of 4 Mk282 Iss 2 13/09/2018 AJM
Step 5 RNC Conguration:
Setting up of the RNC is carried out by completing the following:
MASTER CONTROL PANELS RNC SLAVE CONTROL PANELS RNC
STEP A: At the master control panel, set
the network address to 1.
From Taktis panel front Screen> Activate
Controls> Enter PIN> Engineer Options>
Conguration> Edit Conguration> Panel
Settings>
STEP B: At the RNC, ‘Set Node Number to
1 via menu.
From front Screen> Node Setup> Set Node
Number
NOTE: The Taktis network address & the
RNC address (node number) must match.
STEP C: Set Site ID via menu.
From front Screen> Node Setup> Set Site ID
NOTE: Site id is taken from this RNCs
ident label.
STEP A: At the slave control panel, set the
network address between 2 & 16.
From Taktis panel front Screen> Activate
Controls> Enter PIN> Engineer Options>
Conguration> Edit Conguration> Panel
Settings>
STEP B: At the RNC, ‘Set Node Number
between 2 & 16 via menu.
From front Screen> Node Setup> Set Node
Number
NOTE: The Taktis network address & the
RNC address (node number) must match.
STEP C: Set Site ID via menu.
From front Screen> Node Setup> Set Site ID
NOTE: Site id must match master control
panel RNCs ident.
Once steps A to C have been carried out at all RNCs, go to step D.
Step D: From the master control panel’s RNC menu, a ‘Congure System action must
be performed to nalise conguration:
From front Screen> Node Setup> Congure System
Step 6 Signal Checks:
Once congured, all RNCs will require a signal level check to ensure they are at an
adequate level. The level received must be 30dB or greater.
From front Screen> Node Status> Signal Level
©2018 EMS Ltd. All rights reserved Page 4 of 4 Mk282 Iss 2 13/09/2018 AJM
The information contained within this literature is correct at time of publishing. EMS reserves the right to change any information regarding products as part of its continual development
enhancing new technology and reliability. EMS advises that any product literature issue numbers are checked with its head oce prior to any formal specication being written.
enquiries@emsgroup.co.uk
www.emsgroup.co.uk
+44 (0) 1227 369570
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

EMS FireCell Radio Network Communicator for Taktis Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI