  • Hello! I've reviewed the DeatschWerks Fuel Pump Installation Guide for the DW200 and DW300 models. This guide provides the steps for installing the fuel pump in 92-00 Civic and 94-01 Integra vehicles, including a parts list and instructions for priming. I'm ready to answer your questions about the installation process and the included parts.
  • What vehicles are compatible with these fuel pumps?
    What parts are included with the fuel pump?
    What should I do after installing the fuel pump?
DeatschWerks
92-00 Civic and 94-01 Integra DW200/300 Fuel Pump Installation Guide
1
9-201/301-0846
92-00 Civic and 94-01 Integra DW200/300
Fuel Pump Installation Guide
Parts List:
DW200/300
Fuel Sock
3” Submersible Fuel Injection Hose
5/16” Hose Clamps (x2)
Fuel Sock Retainer Clip
DeatschWerks
92-00 Civic and 94-01 Integra DW200/300 Fuel Pump Installation Guide
2
92-00 Civic and 94-01 Integra DW200/300 Fuel Pump Install
PLEASE READ this guide is intended to aid in the installation of our products. It is recommended that
factory manuals or instructions are followed to remove the fuel pump assembly from the vehicle. Some
instructions in this guide are generic. The factory manual should supersede any contradiction.
Below is a picture of suggested tools that will make the installation process easier.
DeatschWerks
92-00 Civic and 94-01 Integra DW200/300 Fuel Pump Installation Guide
3
1 remove the green retainer from the electrical connector, it may be discarded if damaged during
removal
2 disconnect the electrical connector and remove the fuel sock
3 remove the OE pump from the assembly, do not discard the OE pump isolator
DeatschWerks
92-00 Civic and 94-01 Integra DW200/300 Fuel Pump Installation Guide
4
4 cut the supplied hose to length and install on the assembly using the DW supplied hose clamps
5 install the supplied fuel sock on the DW200/300 with the fuel sock retainer and install the pump into
the assembly
DeatschWerks
92-00 Civic and 94-01 Integra DW200/300 Fuel Pump Installation Guide
5
6 plug the electrical connector into the DW200/300 and the assembly is ready to be installed in the fuel
tank
7 reinstall the assembly into the fuel tank and attach a length of hose to the outlet of the pump
assembly allowing it to drain into a fuel safe container and prime the fuel pump assembly
8 cycle the key to the on position as many times as required to prime the pump assembly and evacuate
the air introduced during the pump installation process
9 attach supply line to the outlet of the pump assembly
/