INFORMATION SHEET
Calibre Basin Mixer
Product code: CBM
160
80
100
40
35
48
sussextaps.com.au
5.0 litres per
minute
Licence No. 0124
In accordance with AS/NZS 6400
Sussex Taps Pty Ltd
WATER RATING
www.waterrating.gov.au
The more
stars the more
water efcient
AS/NZS 3718:2005
LIC. 20081
Calibre
Calibre Basin Mixer
Product code: Available options:
CBM Basin Mixer
CEBM Extended Basin Mixer
INSTALLATION GUIDE
PLUMBER NOTE
-On-site testing using higher water pressures must be
conducted with the Mixer in the closed position.
(STATIC TEST )
-Under no circumstances is the Mixer to be opened
when exceeding the maximum stated water pressure.
-At the completion of testing, do not relieve any high
water pressure by operating the Mixer.
-Exposing the internals of the Mixer Cartridge to higher
than specified water pressures will void the
manufacturers warranty.
INSTALLATION GUIDELINES
-The Mixer is supplied assembled, only the Fixing nut
and the Clamp need to be removed.
-After removing the mentioned parts, lower the Mixer
on to the mounting surface and fit the Flexible Hoses.
-In some cases the Flexible Hoses may need to be fed
through from under the mounting surface and then
attached. (Tighten using appropriate spanner)
-After securing the Flexible Hoses, fit Clamp and attach
the Fixing Nut from underneath.
-Before fully securing the Mixer ensure that the Base O
Ring is intact and the Mixer is properly centered over
the mounting surface hole.
-The Mixer mounting surface must be completely sealed
and water-tight.
-The 1/2” Fittings of the Flexible Hoses have a conical
seal, ensure that the matching threads are cut square
and burr free.
-Prior to connecting the Flexible Hoses, ensure all
pipework is thoroughly flushed and ensure pipework is
free of any dirt or debri.
-Isolating Stop Valves are recommended with all
installations. (not supplied)
-Connect the Flexible Hoses to Hot and Cold pipework
fittings, ensure the Hoses do not kink or become
twisted when tightening.
-Check all fittings and connections are secure and
water-tight.
BASE
O-RING
CLAMP
Hole Size
32-35mm
50mm Max.
Bench thickness
1/2" BSP Fittings
with conical Seals FLEXIBLE HOSES
FIXING
NUT
HO T/ CO LD
FE ED CH A NN EL
HO T/ CO LD
FE ED CH ANNEL
Ap p rox.
400m m
Ap pro x.
400m m
CONCRETE RECES REQUIREMENTS
FIXED AND CONNECTED VALVE BACK FILLED RECESS
FIXINF AND CONNECTIONS
(FIXING VALVE)
Fixing and connections (Fig. 2 & 3)
Back-filled recess (Fig. 4)
Existing concrete floor
New concrete floor (pre-pour)
*To install the Floormount Fixing Valve a 50mm step down (recess) is required in the concrete surface where
the floormount is to be located.
- The recess area is to be a minimum of 200 x 300mm to allow enough room for the fixing valve to be fitted.
NOTE: This can be a larger area if unsure of exact mounting position.
Important: the recess area is required to be 50mm deep and must be flat and level.
- Connect 1/2” elbows (or male/female nipples) to Fixing Valve in preparation for the hot/cold water lines.
- Postion fixing valve into concreted recess area.
NOTE: Align “Front” to face bath or wash vessel.
- Mark and drill for 8mm “dyna bolt” or other appropriate anchoring bolts (not supplied).
- Fix Floormount Fixing Valve and complete hot and cold water line connections.
- Ensure the valve is level and well anchored.
- Tighten “end caps” and perform water testing, and ensure there are no water leaks.
- Leave end caps, pressure plate and fixing bolts in the valve to protect the threads until final fit-off.
- Once all water connections are made and tested, fill in the recessed area and channelling up to the
Fixing Valve with a mortar mix.
- After mortar has set, seal the area between mortar and the Fixing Valve.
- Cut 400 x 400mm section through concrete slab where the floormount mixer is to be located (Fig. 1).
- Remove cut section and drill for the appropriate concrete ‘tie-rods’ into side walls of cavity.
- Fit ‘tie-rods’ and pour concrete to create a 50mm step down (recess) from the original concrete
floor surface (Fig. 1).
NOTE: Recess area must be flat and level.
- Hot and cold lines can be chased into the recessed area by cutting a minimum 50 x 50mm channel (Fig. 1).
*To install this floormount fixing valve, a 50mm step down (recess) is required in the concrete slab. The floormount fixing
valve is supplied with end caps, pressure plate and fixing bolts. Leave intact until final fit off with the floormount mixer.
Floormount mixer Concrete floor Rough-in