Medtronic Sure VentLine H Set User manual

Type
User manual

This manual is also suitable for

1
© 2013 Oridion Medical 1987 Ltd.
All rights reserved.
PN 011044G
Products for Intubated Patients
Directions for Use
ETCO
2
SAMPLING
Sure VentLine
TM
H Set
Adult/Pediatric
Sure VentLine
TM
Set
Adult/Pediatric
3
Surestream
TM
EtCO
2
Sampling
for Intubated Patients
1
2
4
3
Instructions for use:
Firmly connect the small-end (male) of the Surestream
TM
Airway Adapter to the female-end of the Wye piece
(ventilation source) .
Firmly connect the patient’s endotracheal tube connec-
tor into the large-end (female) of the Surestream
TM
Airway Adapter.
Ensure that the tubing is not twisted or crimped.
Insert the Surestream connector securely but gently
into the CO
2
input connector on the device .
Instructions for use with a closed suction system:
Firmly connect the large-end (female) of the Sure-
stream
TM
airway adapter to the ventilator connector on
the closed suction system.
1.
2.
3.
4.
1.
3
4
2
1
2
4
en
Sure VentLine
®
Sets are for short-term use.
Sure VentLine
®
H Sets are for humidied
ventilation and long-term use.
Airway Adapters for Adult to Pediatric patients:
• Added dead space <6.6 cc.
• To be used with an endotracheal tube > 4.5mm bore.
Single patient use, not to be re-processed
Non-sterile / non-pyrogenic
Does not contain natural rubber latex
Warning: When using with a closed suction system, do
not place the airway adapter (tee) between the
suction catheter and endotracheal tube. This is
to ensure that the airway adapter does not inter-
fere with the functioning of the suction catheter.
Warning: Loose or damaged connections may compro-
mise ventilation or cause an inaccurate mea-
surement of respiratory gases. Securely connect
all components and check connections for leaks
according to standard clinical procedures.
Warning: Check CO
2
and O
2
tubing regularly during use
to ensure that no kinks are present. Kinked tub-
ing may cause inaccurate CO
2
sampling or af-
fect O
2
delivery to patient.
Caution: Ensure that tubing is not stretched during use.
Caution: Do not attempt to clean, disinfect, sterilize or
ushanypartofthesamplinglineasthiscan
cause damage to the monitor.
Caution: Dispose of sampling lines according to standard
operating procedures or local regulations for the
disposal of contaminated medical waste.
Caution: Use of the Sure VentLine
®
H Set (the H in its
name indicatesthat it isfor use in humidied
environments) during MRI scanning may cause
interference. The use of non H sampling lines is
advised.
Note: During nebulization or suction, in order to avoid
moisture buildup and sampling line occlusion,
remove the sampling line luer connector from
the monitor.
Note: Replace the sampling line according to hospital
protocol or when a blockage is indicated by the
device. Excessive patient secretions or a build-
up of liquids in the airway tubing may occlude
the sampling line, requiring more frequent re-
placement.
Federal law (U.S.) restricts this device to sale by or on the
order of a physician.
Surestream
TM
EtCO
2
Sampling
for Intubated Patients
Adult and Pediatric Patients
30
Do not reuse
Does not contain natural rubber latex
Fire hazard
Storage temperature
Rx only
Caution, consult accompanying documents
CE mark
ONLY
Does not
contain natural
rubber latex
31
This product is covered by one or
more of the following US patents:
6,422,240; 5,857,461; 6,437,316
6,926,005; 5,657,750; 7,383,839;
7,500,483; 6,783,573; and their
foreign equivalents. Additional patent
applications pending.
www.oridion.com
Oridion Medical 1987 Ltd.
Har Hotzvim Science-
Based Industrial Park
P.O. Box 45025
Jerusalem 91450, Israel
Tel: 972-2-589-9111
Fax: 972-2-582-5873
Oridion Capnography Inc.
Needham MA 02494
USA
Tel: (781) 453-0500
Toll Free: 1-800-ORIDION
Obelis S.A.
Av. De Tervuren, 34 Bte. 44
B-1040 Brussels
Belgium
Tel: +32.2.34.33.87
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Medtronic Sure VentLine H Set User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI