  • Hello! I've reviewed the user manual for the Cumberland Climate controller EXPERT V22. This document provides detailed instructions on the controller's wiring, installation, and usage. It highlights features like multiple sensor inputs, variable output capabilities, and backup thermostat usage, and more. Feel free to ask me any questions about the manual or the Climate controller's functions.
  • What is the recommended clearance for mounting the enclosure on the wall?
    Where should the wires be introduced into the controller?
    What type of output should the water meter have?
    What type of cable should be used for the water meter?
EXPERT V22
J2 Connector
Connection
for top board
1
A B C D E F G H I J K L M N O
STAGE 4
INSIDE T°
OUTSIDE
SENSOR # 4 (OPT.)
INSIDE T°
SENSOR # 3 (OPT.)
INSIDE T°
SENSOR # 2 (OPT.)
OUTSIDE T°
Humidity
SENSOR (OPT.)
Sensor (Opt.)
Dwyer Gauge
Static Pressure
Sensor (Opt.)
WATER
METER
MPV
stage 1
(OPTIONAL)
MPV
stage 2
(OPTIONAL)
INSIDE T°
SENSOR # 1
STAGE 3
GND Controller
TO BRIDGE-A
TO TERMINAL # 8
TO TERMINAL # 9
Power Supply
230 Vac (115 Vac)
Stage 2
Power Supply
Variable Output
Variable-speed Fan
Backup
Thermostat*
(Not included)
Backup Thermostat*
(Not included)
Variable-speed Fan
Fan, Heater or Mister
Fan, Heater or Mister
On-Off
On-Off
230 Vac (115 Vac)
Stage 1
Stage 3
Power Supply
Variable Output
230 Vac (115 Vac)
Power Supply
On/Off Output
230 Vac (115 Vac)
Stage 4
Power Supply
On/Off Output
230 Vac (115 Vac)
L1
L1
L2 (N)
GND
L2 (N)
L1
GND
L2 (N)
L1
GND
L2 (N)
L1
GND
L2 (N)
V1 IN1 V2 IN2 LL2/N
2 3 4 5 6 7 8 9 10 11 12 13 14 15
1
1G1G
A B C D E F G H I J K L M N O
NO
OUT
GND OUT GND OUT GND PWR
-
OUT
PC1
PC2
0-10V
-
0-10V
+
0-10V
-
0-10V
+
0-5V 4-20mA Power
+
Alarm
0-10V
Load 2
0-10V
Load 1
COM
VDC
C
NC
(OPTIONAL)
2 3 4 5 6 7 8 9 10 11 12 13 14 15
Voltage Selector
115/230 Vac
230 V
Communication
Connection
(Comlink-1 Card)
Cable Entry:
Punch holes at the bottom of the
enclosure to allow wires to be
introduced in the controller. Do not
drill the top or side panels of the
enclosure.
Fuse Box:
We recommend installing a fuse
box on each stage.
Variable Output Capacity:
115VAC 1/2HP (373W),
230VAC 1.5HP (1120W),
10 Amp Max.
ON/OFF Ouput Capacity:
115VAC 1/4HP (187W), 230VAC
1/2HP (373W), 7.5 Amp Res. Max.
We recommend installing external
relays on "on/off" stages hooked to
motors.
from control
Coil power source
Stage
output
to distribution panel
stage input
Coil
COM
N.O.
COM
N.O.
Actuator (winch): Open/Close
output, 120VAC (0.17HP 124W),
240VAC (0.5HP 373W), 30 VDC
5A Ind.
Water Meter: The water meter
output should be a dry contact
and should not pulse faster than
60 times a second (60 Hz).
A 22/12 AWG gauge cable no
longer than 2000 feet (0.6 km)
can be used to connect the
water meter. Do not use a cable
longer than 2000 feet even
if a larger cable is used. Do not
run the meter cable outside the
building !
Notes:
1. Installation of a good quality
alarm system is strongly
suggested to warn of power
failures and high/low
temperatures.
2. Provide a surge protection
(including lightning protection)
from the power supply to the
controller and from the control to
the sensors. Consult a certified
electrician if required.
3. Same phases must be used to
power the variable fans and the
controls on 3 phases power.
*Backup Thermostats:
The backup thermostats are
shown for illustration purposes
only. Sufficient backup
thermostats must be used to
ensure ventilation if the controller
loses power.
Mounting the Enclosure
on the Wall:
Leave a clearance of at
least 12" to the left of the
controller to allow the
cover to be removed for
maintenance.
12"
Cumberland: http://www.cumberlandpoultry.com
AP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777
REV 04
WIRING DIAGRAM
EXPERT V22
#891-00019 REV 02
Please scan the QR Code to access the complete
manual or visit the website.
EN
Cumberland
AP
ADO1217809
Page 1
/