EXPERT V22
J2 Connector
Connection
for top board
1
A B C D E F G H I J K L M N O
STAGE 4
INSIDE T° T°
OUTSIDE
T°
T°
T°
SENSOR # 4 (OPT.)
INSIDE T°
SENSOR # 3 (OPT.)
INSIDE T°
SENSOR # 2 (OPT.)
OUTSIDE T°
Humidity
SENSOR (OPT.)
Sensor (Opt.)
Dwyer Gauge
Static Pressure
Sensor (Opt.)
WATER
METER
MPV
stage 1
(OPTIONAL)
MPV
stage 2
(OPTIONAL)
INSIDE T°
SENSOR # 1
STAGE 3
GND Controller
TO BRIDGE-A
TO TERMINAL # 8
TO TERMINAL # 9
Power Supply
230 Vac (115 Vac)
Stage 2
Power Supply
Variable Output
Variable-speed Fan
Backup
Thermostat*
(Not included)
Backup Thermostat*
(Not included)
Variable-speed Fan
Fan, Heater or Mister
Fan, Heater or Mister
On-Off
On-Off
230 Vac (115 Vac)
Stage 1
Stage 3
Power Supply
Variable Output
230 Vac (115 Vac)
Power Supply
On/Off Output
230 Vac (115 Vac)
Stage 4
Power Supply
On/Off Output
230 Vac (115 Vac)
L1
L1
L2 (N)
GND
L2 (N)
L1
GND
L2 (N)
L1
GND
L2 (N)
L1
GND
L2 (N)
V1 IN1 V2 IN2 LL2/N
2 3 4 5 6 7 8 9 10 11 12 13 14 15
1
1G1G
A B C D E F G H I J K L M N O
NO
OUT
GND OUT GND OUT GND PWR
-
OUT
PC1
PC2
0-10V
-
0-10V
+
0-10V
-
0-10V
+
0-5V 4-20mA Power
+
Alarm
0-10V
Load 2
0-10V
Load 1
COM
VDC
C
NC
(OPTIONAL)
2 3 4 5 6 7 8 9 10 11 12 13 14 15
Voltage Selector
115/230 Vac
230 V
Communication
Connection
(Comlink-1 Card)
Cable Entry:
Punch holes at the bottom of the
enclosure to allow wires to be
introduced in the controller. Do not
drill the top or side panels of the
enclosure.
Fuse Box:
We recommend installing a fuse
box on each stage.
Variable Output Capacity:
115VAC 1/2HP (373W),
230VAC 1.5HP (1120W),
10 Amp Max.
ON/OFF Ouput Capacity:
115VAC 1/4HP (187W), 230VAC
1/2HP (373W), 7.5 Amp Res. Max.
We recommend installing external
relays on "on/off" stages hooked to
motors.
from control
Coil power source
Stage
output
to distribution panel
stage input
Coil
COM
N.O.
COM
N.O.
Actuator (winch): Open/Close
output, 120VAC (0.17HP 124W),
240VAC (0.5HP 373W), 30 VDC
5A Ind.
Water Meter: The water meter
output should be a dry contact
and should not pulse faster than
60 times a second (60 Hz).
A 22/12 AWG gauge cable no
longer than 2000 feet (0.6 km)
can be used to connect the
water meter. Do not use a cable
longer than 2000 feet even
if a larger cable is used. Do not
run the meter cable outside the
building !
Notes:
1. Installation of a good quality
alarm system is strongly
suggested to warn of power
failures and high/low
temperatures.
2. Provide a surge protection
(including lightning protection)
from the power supply to the
controller and from the control to
the sensors. Consult a certified
electrician if required.
3. Same phases must be used to
power the variable fans and the
controls on 3 phases power.
*Backup Thermostats:
The backup thermostats are
shown for illustration purposes
only. Sufficient backup
thermostats must be used to
ensure ventilation if the controller
loses power.
Mounting the Enclosure
on the Wall:
Leave a clearance of at
least 12" to the left of the
controller to allow the
cover to be removed for
maintenance.
12"
Cumberland: http://www.cumberlandpoultry.com
AP: http://www.automatedproduction.com
GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777
REV 04
WIRING DIAGRAM
EXPERT V22
#891-00019 REV 02
Please scan the QR Code to access the complete
manual or visit the website.
EN
Cumberland
AP
ADO1217809
Page 1