Ledalite SilkSpace Install Instructions

Type
Install Instructions
Designed to permit use of grid (NEMA G) fi xtures
in ceilings requiring fl anges.
Extruded aluminum construction with mitered
corners.
Includes screws for complete assembly.
System available for continuous row mounting.
© 2009 Ledalite Architectural Products Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA (5332) Fax: 604-888-2003 www.ledalite.com
DRYWALL KIT
MOUNTING FRAME ASSEMBLY
2’x2’, 2’x4’, 1’x4’
FOR MOUNTING IN DRYWALL OR
CEILINGS REQUIRING FLANGES
25 5/16"
25 5/16"
49 5/16"
25 5/16"
49 5/16"
13 5/16"
2'x2'
2'x4'
1'x4'
FRAME SIZES
FRAME DIMENSIONS
MOUNTING OPTIONS
Wood Frame Hanger Wire
Wood frame and screws
supplied by others.
Hanger wires
supplied by others.
Screw
Wood
Frame
Drywall
Hanger Wire
Drywall
L0271 Rev. 3.5
© 2009 Ledalite Architectural Products Phone: 604-888-6811 Toll Free Fax: 1-800-665-LEDA (5332) Fax: 604-888-2003 www.ledalite.com
DRYWALL KIT MOUNTING FRAME ASSEMBLY
2’x2’, 2’x4’, 1’x4’
CEILING OPENING - STANDALONE
AA
AA
ABB
BB
B
Fixture Size A B
2’x2’ 24 5/8(626mm) 24 5/8(626mm)
2’x4’ 24 5/8(626mm) 48 5/8(1235mm)
1’x4’ 12 5/8(321mm) 48 5/8(1235mm)
FINISH: Extruded aluminum construction with mitered corners.
White baked polyester enamel minimum 85% refl ectance. Phos-
phate undercoating.
We reserve the right to change materials and fi nish in any way that will not alter
installed appearance or reduce function and performance.
SPECIFICATIONS
Fixture Size
Catalogue Number
Standalone
Mounting Frame
Continuous Row
Mounting Frame
2’x2’ 300DK03
2’x4’ 300DK04 300DK09
1’x4’ 300DK02 300DK08
ORDERING GUIDE
For continuous row mounting, use one standalone mounting frame
per row with multiple continuous row mounting frames.
CC
CC
C
DD
DD
D
Mounting Frame for
coutinuous row mounting
(FK CRM)
Standalone
Mounting Frame
Continuous Row
Mounting Frames
* Use the ceiling opening length (B) of one standalone mounting
frame and add 48 3/16(1224mm) for each continuous row mount-
ing frame required.
Fixture Size C D
2’x2’
2’x4’ 24 5/8(626mm) see below*
1’x4’ 12 5/8(321mm) see below*
CC
CC
C
DD
DD
D
CEILING OPENING - CONTINUOUS ROW
Example:
Total ceiling opening length (D)
385 15/16
=
Ceiling opening length per frame
337 5/16
x 7
48 3/16
48 5/8
x 1
48 5/8
Continuous RowStandalone
Type of mounting frame assembly
+
For a row of 8 fi xtures
Frames required per row
300DK10
  • Page 1 1
  • Page 2 2

Ledalite SilkSpace Install Instructions

Type
Install Instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI