Crestron QM-RMC User manual

Type
User manual
Crestron QM-RMC Room Media Controller
Room Media Controller:
QM-RMC
Purpose
The purpose of this addendum is to provide additional information not supplied with
the original QM-RMC Operations Guide (Doc. 6161). Specifically, this addendum
includes the procedure for establishing Ethernet slave in console mode. If necessary,
refer to Addendum #1 for console mode information.
Establishing Console Mode on an Ethernet Slave
Entering serial console mode on an Ethernet slave is no different than on a master
processor: hold down the SW-R button while booting up. Once you enter serial
console mode, the COM B LED will flash.
Please be aware that doing this causes the processor to boot up in standalone mode,
rather than Ethernet slave mode. You will notice that the Ethernet master shows this
device as being off-line.
To put the processor back in Ethernet Slave mode and use the serial console,
type REBOOT at the console prompt. This will reboot the processor in slave mode,
and enable the serial console.
NOTE: Booting up in serial console mode will render COM B useless to the
program, as it is being used for the serial console.
To terminate the serial console mode, press the HW-R switch, or cycle the power.
NOTE: Pressing <F10> (Program Reset) in Viewport may cause errors if both the
program and the console mode are using the same COM port.
Crestron Electronics, Inc. Addendum #2 for Doc. 6161
15 Volvo Drive Rockleigh, NJ 07647 11.03
Tel: 888.CRESTRON
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
  • Page 1 1

Crestron QM-RMC User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI