Titon Solace TP200/BA Installation guide

Type
Installation guide

This manual is also suitable for

Titon Solace TP200/BA is a versatile axial fan designed for efficient air extraction in various indoor spaces. Its compact size makes it suitable for bathrooms, toilets, and kitchens. The fan offers multiple installation options, including wall, ceiling (with an optional kit), and window (with an optional kit).

Key features of the Titon Solace TP200/BA include:

  • Adjustable trickle speed: Set the desired airflow rate at a low speed for continuous ventilation, with options of 6, 8, or 13 liters per second.
  • Boost function: Activate a higher fan speed temporarily using an external switch, PIR sensor, or light switch.

Titon Solace TP200/BA is a versatile axial fan designed for efficient air extraction in various indoor spaces. Its compact size makes it suitable for bathrooms, toilets, and kitchens. The fan offers multiple installation options, including wall, ceiling (with an optional kit), and window (with an optional kit).

Key features of the Titon Solace TP200/BA include:

  • Adjustable trickle speed: Set the desired airflow rate at a low speed for continuous ventilation, with options of 6, 8, or 13 liters per second.
  • Boost function: Activate a higher fan speed temporarily using an external switch, PIR sensor, or light switch.
1
G
Installation manual
Solace - Axial fan
TP200/BA: Basic
TP200/RT: with Timer
TP200/HT: with Humidistat/Timer
Fig. 1
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
Read this manual carefully before using the product and keep it in
a safe place for reference.
This product was constructed up to standard and in compliance with
regulations relating to electrical equipment and must be installed by
technically qualified personnel. The manufacturer assumes no
responsibility for damage to persons or property resulting from
failure to observe the regulations contained in this booklet.
•Thedeviceshouldnotbeusedforapplicationsotherthanthosespeciedinthismanual.
•Afterremovingtheproductfromitspackaging,verifyitscondition.Incaseofdoubt,
contactaqualiedtechnician.Donotleavepackaging
within the reach of small children or people with disabilities.
•Donottouchtheappliancewithwetordamphands/feet.
•Thisappliancecanbeusedbychildrenagedfrom8yearsandaboveandpersonswith
reducedphysical,sensoryormentalcapabilitiesorlackofexperienceandknowledge
if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
•Do not use the product in the presence of ammable vapours, such as alcohol,
insecticides,gasoline,etc.
•Ifanyabnormalitiesinoperationaredetected,disconnectthedevicefromthemains
supplyandcontactaqualiedtechnicianimmediately.Use original spare parts only
for repairs.
•Theelectricalsystemtowhichthedeviceisconnectedmustcomplywithregulations.
•Beforeconnectingtheproducttothepowersupplyorthepoweroutlet,ensurethat:
- the data plate (voltage and frequency) correspond to those of the electrical mains
-theelectricalpowersupply/socketisadequateformaximumdevicepower. Ifnot,
contactaqualiedtechnician.
•The device should not be used as an activator for water heaters, stoves, etc., nor
shoulditdischargeintohotair/fumeventductsderivingfromanytypeofcombustion
unit.Itmustexpelairoutsideviaitsownspecialduct.
•Operatingtemperature:0°Cupto+50°C.
•Thedeviceisdesignedtoextractcleanaironly,e.g.withoutgrease,soot,chemicalor
corrosiveagents,orammableorexplosivemixtures.
•Donotleavethedeviceexposedtoatmosphericagents(rain,sun,snow,etc.).
•Donotimmersethedeviceoritspartsinwaterorotherliquids.
•Turnoffthemainswitchwheneveramalfunctionisdetectedorwhencleaning.
•For installation an omnipolar switch should be incorporated in the fixed wiring, in
2
accordancewiththewiringregulations,toprovideafulldisconnectionunderovervoltage
categoryIIIconditions(contactopeningdistanceequaltoorgreaterthan3mm).
•Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer,itsservice
agent or similarly qualified persons in order to avoid a hazard.
•Donotobstructthefanorexhaustgrilletoensureoptimumairpassage.
•Ensureadequateairreturn intotheroomincompliancewithexisting regulationsin
order to ensure proper device operation.
•Iftheenvironmentinwhichtheproductisinstalledalsohousesafuel-operatingdevice
(waterheater,methanestoveetc.,thatisnota“sealedchamber”type),itisessential
to ensure adequate air intake, to ensure good combustion and proper equipment
operation.
•Installthe productso thatthe impelleris notaccessible fromtheair outletside as
verifiedbycontactwiththeTestFingerincompliancewiththecurrentsafetyregulations.
•Ceiling installation
InordertoguaranteetheIPX4degreeofprotectionagainstmoistureincaseofceiling
installation,usetheappropriateceilingmountkit(TP202),whichisnotincluded.Use
only the rear entry hole for supply cables. If there is a possibility of condensation
alongtheairdischargeduct,provideadrainagesystemtopreventcondensationfrom
discharging into the environment through the fan.
Attention: do not mount the product on the ceiling without this kit.
•Window installation
Incaseofwindowinstallationitisnecessarytousetheappropriatewindowkit,which
is not included.
Attention: do not mount the product on the window without this kit.
•Material:highquality,impactandUV-resistantABScolourRAL9010.
•Designfrontcoverremovableforcleaningwithouttheuseoftools.
•Rearreinforcementringtopreventspigotdeformationduringinstallation.
•High efciency aerodynamic fan with “winglet” blades to optimise quietness and
efciency.
•SinglephaseECBrushlessmotorwithintegralthermalprotection.
•Motormountedonhighqualityballbearings.
•Thefanisdoubleinsulated:noearthconnectionisrequired.
•Tricklespeedselectableduringinstallation:6,8,13l/soroff.
•Optiontoboostfromtrickle(orfromoff)throughLSconnection.
•Installationtypeselectionavailable(throughwallorducted).
•IPX4degreeofprotection.
•Max.consumptionoffanisapproximately50mA.
•Powersupply220Vto240V~50Hz.
Model Airflow
Static pressure
Pa max
Power
W max
Sound pressure
dB(A) @3m
Solace
m
3
/h l/s
27 2.5 26/23/13/11
83/47/29/21 23.1/13/8/6
INTRODUCTION
Solace(fig.1)isanaxialfandesignedtoensureairextractioninsmall/medium-sized
roomssuchasbathrooms,toiletsandkitchens.
Suitableforairdischargedirectlytotheoutsideorinthepresenceofshortductedsystem.
Wall,ceilingorwindowinstallation(fig.2).
TECHNICAL SPECIFICATIONS
3
BASIC
The fan runs continuously at selected trickle speed (set by the jumper switch combination
-g.16)andcanbeboostedwithadedicatedON/OFFswitch(orPIR,CO2…sensor)or
withalightswitch(g.14A).Tricklespeedcanbesettooff.
WITH OVER-RUN TIMER
Thefanisprovidedwithover-runtimer,adjustablefrom0toapprox.30minutesvia
trimmer(g.15B).
The fan runs continuously at selected trickle speed (set by the jumper switch combination
-g.16)andcanbeboostedwithadedicatedON/OFFswitch(orPIR,CO2…sensor)or
withalightswitch(g.14B).Tricklespeedcanbesettooff.
Whentheexternalswitchisturnedon,thefanisboosted.Aftertheexternalswitchis
turnedoff,thefancontinuestorunatboostspeedforasettableperiodoftime,then
it returns to selected trickle speed. The over-run timer function is activated only if the
externalswitchhasbeenonforatleast60seconds.
WITH HUMIDISTAT/TIMER
Thefanisequippedwithahumiditysensor,whosethresholdisadjustablefrom50%to
95%RelativeHumidityviadedicatedtrimmer,andwithatimerwhichisadjustablefrom
0toapprox.30minutesviadedicatedtrimmer(g.15C).
The fan runs continuously at selected trickle speed (set by the jumper switch combination
-g16),increasesitsspeedincasethepercentageofRelativeHumidityexceedsthe
settablethreshold,andcananywaybeboostedwithadedicatedON/OFFswitch(orPIR,
CO2…sensor)orwithalightswitch(g.14C).Tricklespeedcanbesettooff.
Todeactivatethehumidistatfunction,turnthetrimmerHYcompletelyclockwise.
Automatichumidistatoperation:whenthepercentageofRelativeHumidityexceedsthe
settablethreshold,fanspeedautomaticallyincreasesto“comfortboost”speed,which
is intermediate between the selected trickle speed and the boost speed. When the
percentageofRelativeHumiditygoesbelowthethreshold,thefancontinuestofunction
at“comfortboost”speedforafactorysetperiodoftimethenreturnstoselectedtrickle
speed.
Operationwithexternalswitch:whentheexternalswitchisturnedon,thefanisboosted.
Aftertheexternalswitch isturned off,thefan continuesto runat boostspeed fora
settableperiodoftime,thenitreturnstoselectedtricklespeed(orto“comfortboost”
speedincaseautomatichumidistatoperationison).ThefrontcoverLEDindicateswhen
theexternalswitchison.Theover-runtimerfunctionisactivatedonlyiftheexternal
switchhasbeenonforatleast60seconds.
VERSIONS
INSTALLATION TYPE SETTING
InstallationtypecanbeselectedusingJUMPER1betweenthefollowingoptions:through
wallorducted(g.16).
TricklespeedcanbeselectedusingJUMPER2andJUMPER3betweenthefollowing
options:6,8,13/soroff(g.16).
TRICKLE SPEED SETTING
4
ceiling (accessory on demand)
window (kit on demand)
wall
directexhausting
perimetricalexhausting
INSTALLATION (Fig.2)
short ducting
STANDARD CONFORMITY
2014/35/ECLowVoltageDirective(LVD)
2014/30/ECElectromagneticCompatibility(EMC),
inconformitywiththefollowingstandards:
ElectricalSafety:EN60335-1(2012)+A11+A13;EN60335-2-80(2003)+A1+A2.
ElectromagneticCompatibility:EN55014-1(2017);EN55014-2(2015);EN61000-3-
2(2014);EN61000-3-3(2013).
5
Solace= ø99 mm
7
8
Ø
4
6
3
5
6
MOUNTING AND ELECTRICAL WIRING
6
4 x ø 5 mm
9A
10A
11A
13A
12A
ø 10mm
Ø d
Ø
d
SURFACE CABLE
H03VV-F ; H05VV-F
3 X 0.5 ÷ 1.5 mm
2
4 X 0.5 ÷ 1 mm
2
7
11B
12B 13B
10B
9B
4 x ø 5 mm
15A
Solace BA
14A
LS
RECESSED CABLE ENTRY
H03VV-F ; H05VV-F
3 X 0.5 ÷ 1.5 mm
2
4 X 0.5 ÷ 1 mm
2
Solace RT
+
-
TIMER
14B 15B
CLICK
17 18
JUMPER
INSTALLATION AIRFLOW
1 2 3
through wall OFF
through wall 6l/s
through wall 8l/s
through wall 13l/s
in room OFF
in room 6l/s
in room 8l/s
in room 13l/s
16
= Jumper present
Solace HT
14C
+
-
TIMER
15C
HY
+
-
9
24
26
MAINTENANCE / CLEANING
22
23
ON
OFF
25
19 20 21
ON
OFF
10
Informationondisposalofunitsattheendoflife.
ThisproductcomplieswithEUDirective2002/96/EC.
The symbol of the crossed-out dustbin indicates that this product must
be collected separately from other waste at the end of its life. The user
must,therefore,disposeoftheproductinquestionatsuitableelectronic
andelectro-technicalwastedisposalcollectioncentres,orelsesend
theproductbacktotheretailerwhenpurchasinganew,equivalenttype
device.
Separate collection of decommissioned equipment for recycling,
treatment and environmentally compatible disposal helps to prevent
negative effects on the environment and on health and promotes the
recycling of the materials that make up the equipment.
Improperdisposaloftheproductbytheusermayresultinadministrative
sanctions as provided by law.
DISPOSAL AND RECYCLING
11
a)
Mark
-
TITON
b)
Model
-
TP200/BA, TP200/RT TP200/HT
c)
SEC class
-
E C
c1)
SEC warm climates
kWh/m2.a
-5,4 -11,3
c2)
SEC average climates
kWh/m2.a
-13 -25,7
c3)
SEC cold climates
kWh/m2.a
-26,4 -50,7
Energy label
-
No
d)
Unit typology
-
Residenal - unidireconal
e)
Type of drive
-
mul speed drive
f)
Type of Heat Recovery System
-
absent
g)
Thermal eciency of heat recovery
%
N/A
h)
Maximum ow rate
m3/h
83
i)
Electric power input at maximum ow rate
W
2,6
j)
Sound power level (L
WA
)
dBA
44
k)
Reference ow rate
m3/h
61
l)
Reference pressure dierence
Pa
10
m)
Specic power input (SPI)
W/m3/h
0,028
n1)
Control factor
-
1 0,65
n2)
Control typology
-
Manual control (no DCV) Local demand control
o1)
Maximum internal leakage rate
%
N/A
o2)
Maximum external leakage rate
%
N/A
p1)
Internal mixing rate
%
N/A
p2)
External mixing rate
%
N/A
q)
Visual lter warning
-
N/A
r)
Instrucons to install regulated grilles
-
check the instrucon booklet
s)
Internet address for pre/disassembly instrucons
-
www.ton.com
t)
Airow sensivity to pressure variaons
%
N/A
u)
Indoor/outdoor air ghtness
m3/h
52
v1)
AEC - Annual electricity consumpon - warm climates
kWh
0,4 0,2
v2)
AEC - Annual electricity consumpon - average climates
kWh
0,4 0,2
v3)
AEC - Annual electricity consumpon - cold climates
kWh
0,4 0,2
w1)
AHS - Annual heang saved - warm climates
kWh
6,3 11,9
w2)
AHS - Annual heang saved - average climates
kWh
14 26,2
w3)
AHS - Annual heang saved - cold climates
kWh
27,3 51,3
ErP Directive - Regulations 1253/2014 1254/2014
CFI00020-04-1018
894TheCrescent,ColchesterBusinessPark,Colchester,Essex,C049YQ,UnitedKingdom
Tel:+44(0)1206814879Fax:+44(0)1206543126
Email:[email protected]Web:www.titon.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Titon Solace TP200/BA Installation guide

Type
Installation guide
This manual is also suitable for

Titon Solace TP200/BA is a versatile axial fan designed for efficient air extraction in various indoor spaces. Its compact size makes it suitable for bathrooms, toilets, and kitchens. The fan offers multiple installation options, including wall, ceiling (with an optional kit), and window (with an optional kit).

Key features of the Titon Solace TP200/BA include:

  • Adjustable trickle speed: Set the desired airflow rate at a low speed for continuous ventilation, with options of 6, 8, or 13 liters per second.
  • Boost function: Activate a higher fan speed temporarily using an external switch, PIR sensor, or light switch.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI