Typical Topology 2 - powering up two devices with different voltage
GPON ONT
Wireless Router
Internet
9V/12V DC Power Output
12V DC Power Output
LED
On
On
On
Blinking
On
Blinking
On
Blinking
AC mode
30%
60%
100%
All 3 power indicators blinking 10 times simultaneously
AC mode
60%~100% battery
Charging battery
30%~60% battery
Charging battery
0%~30% battery
Charging battery
Overloaded
ExplanationStatus
AC Input 220V~240V
Smart 30W Mini UPS
Important safety information
Handle the UPS with care. It contains sensitive electronic components, including batteries,
and can be damaged if dropped, burned, punctured, or crushed, or if it comes in contact
with liquid. Don't use a damaged UPS.
The UPS and small parts included in the UPS may present a choking hazard to small
children. Keep them away from small children.
The battery is charged automatically; Press the on/off switch to turn on all output ports;
Press and hold the on/off switch for 3 seconds, all output ports will be turned off.
If the grid is disconnected, UPS will automatically convert to DC mode and battery
provides power for the loads. Press and hold the on/off switch for 3 seconds, all output
ports will be turned off. If you want to turn on the UPS again, press the on/off switch, all
output ports will be turned on.
The UPS contains components and radios that emit electromagnetic fields. the UPS
also contains magnets. These electromagnetic fields and magnets may interfere with
pacemakers, defibrillators, or other medical devices. Maintain a safe distance of
separation between your medical device and the UPS. Consult your physician and
medical device manufacturer for specific information. Stop using the UPS if you suspect
they are interfering with your pacemaker, defibrillator, or any other medical devices.
Don't attempt to replace the batteries yourself. You may damage the batteries, which could
cause overheating and injury.
Batteries
Choking Hazard
WARNING: Medical Device Interference
When overload happens, the power indicators will flash 10 times, then the UPS will be
turned off.
Overload Protection
When short circuit happens, the UPS will be turned off.
Short Circuit Protection
AC Mode
DC Mode
Note:
1.
2.
3.
The total power of all loads cannot exceed the maximum output power. When the
UPS is over loaded, the 3 power indicators will flash at the same time and all output
ports will be turned off.
When UPS works in AC mode, the AC mode indicator turns on. The grid will provide
power for the loads and recharge the UPS battery. After the grid is disconnected,
the battery mode indicator will turn on, UPS battery provides power for the loads.
Power indicators will show the accurate power status. 30% indicator flashes when
the battery is running low, and the UPS may stop working at any time. If battery of
the UPS runs out, the battery will be recharged when the AC is restored, and then
the UPS will restart automatically after few minutes.
If you are not going to use the UPS for a long time, please fully charge it, switch off
and keep it in a cool place. It is recommended to charge the battery every 3
months.
Battery Mode Battery Mode
LED INDICATOR
SAFETY AND HANDLING