300387001
IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303--6234
Telephone (612) 421--6120
Facsimile (612) 422--3232
INSTALLATION MANUAL
PRESSURIZED LIQUID-BASE
Beverage Dispenser
DRIP
TRAY
CUP
REST
FRONT
ACCESS PANEL
SUPPLY INLET
Design data
Width 7 3/4”
Height 15 1/2”
Depth 8 5/8”
Electrical Requirements:(if applicable)
15 Amp Circuit, 115v 60hz
.52 Amp Unit Curent Draw
24v 60hz, Dispensing valves
Installation Check List :
Counter Top with asscess to route
concentrate supply lnes.
15 Amp,115v60hz Outlet, Within 5’
(if applicable)
Cold Water Supply, With Shutoff
Overall Dimensions:
Weight 9 lbs
24VOLT
TRANSFORMER
RECEIVING
Each Unit is completely tested under operating conditions and thoroughly inspected before shipment. At time of
shipment, the carrier accepts the Unit and any claim for damage in transit must be made with the carrier. Upon
receiving Unit from the delivering carrier, carefully inspect the carton for visible indication of damage. Any dam-
age or irregularities should be noted at time of delivery (or not later than 15 days from date of delivery) and im-
mediately reported to the delivering carrier. Request a written inspection report from the Claims Inspector to
substantiate claim. File claim with the delivering carrier, not with IMI Cornelius Inc.
INSTALLATION
Place Unit in selected location and make connections as follows:
Plain Water Source Connections:
1. Flush plain water source thoroughly before connecting to Unit.
2. Connect plain water source to middle 1/4 inch flare fitting labeled ‘‘WATER’’. Use tapered plastic gasket.
Concentrate Line(s) Connection:
1. Connect .265 I.D. concentrate lines to the appropriate inlet fittings. Seal connections using tapered plastic
gaskets. DO NOT CONNECT SOURCE LINES TO CONCENTRATE TANKS AT THIS TIME.
Transformer Connections:
1. On Units with electric valves; connect Unit cord two-pin connector to the mating connector on the trans-
former output (24V) cord.