AOS U650

Air-O-Swiss AOS U650, AOS 7145, AOS 7147 Instructions For Use Manual

  • Hello! I am an AI chatbot trained to assist you with the Air-O-Swiss AOS U650 Instructions For Use Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y
GUARDE TODAS
LAS INSTRUCCIONES!
AOS 7145 / 7147
3
Instructions for use (5 – 22)
en
Instructions d’utilisation (23 – 40)
a
fr
Instrucciones para el uso (41 – 57)
a
es
4
5
en
Instructions for use
6
en
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
Important safety instructions
• Priortousingtheappliance,readthroughthe
instructionsforcompleteuseandretaininasafe
placeforlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithin
thespecifiedtechnicaldata.Improperusecanbe
hazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrent(AC)with
voltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociated
withtheusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyarenearthe
humidifier(image1).
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunction,afterthe
appliancehasbeendropped(3)ordamagedinany
otherway.
• Repairsofelectricalappliancesareonlytobemadeby
qualifiedserviceengineers(4).Improperrepairwork
cancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).
• Do not place the appliance directly on the flooror
nexttoaheatingvent(6).
• Ifthemistcomesincontactwiththefloorpriorto
evaporating,thefloorsurfacecanbecomedamaged.
Wedonotacceptanyliabilityfordamagesinthecase
ofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).
• Alwaysunplugwhennotinuse.
• Onlyoperatethehumidifierwhenitiscompletely
assembled.
• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/
dismantlingofindividualpartsandbeforemovingthe
appliance.
• Donottouchthewaterinthebaseduringoperation
becauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonot
coverwiththrowrugs.Arrangecordsothatitwillnot
betrippedover.
• Neverpulltheplugfromtheoutletbythecableorwith
wethands.
• Donotusetheappliancewherecombustiblegasesor
vaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,
inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.
• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockor
damagetotheappliance.Donotblockairoutletsor
intakes.
• Donotpourwaterintothemistoutletoftheappliance.
• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugis
intendedtofitinapolarizedoutletonlyoneway.Ifthe
plugdoesnotfitfullyintheoutlet,reversetheplug.Ifit
stilldoesnotfit,contactaqualifiedelectrician.DONOT
attempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andthe
ACoutletmaycauseoverheatingandadistortion
oftheplug.Contactaqualifiedelectriciantoreplace
looseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Donotsubmergethemainbodyinwaterorother
liquids.
• Disconnectpowersupplybeforeservicing.
• Personswhoarenotfamiliarwiththeinstructions
foruse,aswellaschildrenandpersonsunderthe
influenceofmedication,alcohol,ordrugsarenot
permittedtooperatetheappliance,orareonly
permittedtooperateitundersupervision.
• Toprotecthealth safetyandproper humidifierfunction
useonlyclean,contamination-free,cold,freshtapwa-
terinyourhumidifier.Ifyourwatersourceiscontam-
inatedorifyouareuncertainofitssafetyusedistilled
water.Inaddition,itisadvisedtoclean and maintain
your humidifierinatimelymanneras instructed in
this manual.
• Theuseofwateradditives,suchasethereal/essential
oils,fragrances,eucalyptus,waterconditionersetc.,
damagesthetankmaterialandasaconsequence
thewholeunit.Anyuseofsuchadditiveswillvoidthe
manufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehigh
frequencyvibrations.
7
en
5
1
3
7
96
2
4
8
8
en
Foreword
CongratulationsonchoosingtheUltrasonicHumidifier
AOS7145/7147fromAIR-O-SWISS!
Didyouknowthatdryroomair:
• Causesthemembranesinyourrespiratorysystemto
dryout,andalsocauseschappedlipsandstinging
eyes?
• Encouragesinfectionsandillnessesofrespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,carpets
andplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?
• Detunesmusicalinstruments?
General information
Acomfortableatmosphereindoorsisreachedwitharela-
tivehumiditylevelbetween40and60%.Yourhumidifier
automaticallycontrolsthehumiditylevelaccordingtothe
desiredsetting.Iftheairistoodry,thehumidifierwillauto-
maticallyswitchon.Assoonasthedesiredhumiditylevel
isreached,itwillswitchoff.
Unpacking
• Carefullyremovethehumidifierfromthebox.Place
yourhandsunderneaththeproducttopullitoutofthe
box(10).
• Warning:Donottaketheunitoutoftheboxbypulling
uponthetankhandle-basemayfallandwillbeda-
maged(11).
•Removetheplasticbagfromthehumidifier.
• Observetheinformationgivenontheratingplateabout
thevoltage.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotusethehumidifierallyearround.
10
11
9
en
Description of the appliance
Mistoutlet(rotating)
Evaporationchamber
Watertank
Demineralizationcartridge
Mainbody
Controlpanel
Watertankcap
HydroStick
PowerPlug
Membrane
Brush
Nebulizerspace
Waterlevelsensor
10
en
Setting up
Findingtheideallocationforyourunit:
• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureof
themistcandamagethefloorsurface(6)(seeSafety
Instructions).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyat
plants,furniture,orotherobjects(12).Keepdistanceof
atleast20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(13).Thegranuleshaveto
absorbwatertoreachmaximumperformance.Ifthe
cartridgeissoakedinthetank,makesuretoexchange
thewaterandemptythewaterfromthebasebefore
usingthehumidifier.
• Onaveragethedemineralizationcartridgeshouldbe
replacedevery2–3monthsdependingonyourwater
hardness.Someareasmayneedtoreplacethecart-
ridgesooner,somemaylastlonger.Thecartridgemust
beexchangedatthelatestafter6monthsortheunit
doesnotreachitsfullperformanceanymore.
 See«Replacementofthedemineralizationcartridge».
• Readtheinstructionsunder«FillingtheTank»for
addingwaterinthehumidifier(14and15).
• Placethewatertankontothebase.
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offdial(18and19).
• About10to15minutesafteritisswitchedonthede-
vicewillreachitsfulloutputlevel.
• Makesurethatthecableisnotpinchedanywhere(9).
Donotoperatethehumidifierifthecableisdamaged
(2).
12
13
11
en
16
17
15 18
19
14
Filling the tank
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Toprotecthealth safetyandproper humidi-
fierfunctionuseonlyclean,contamination-free,
cold,freshtapwaterinyourhumidifier.Ifyour
watersourceiscontaminatedorifyouareuncertainofits
safetyusedistilledwater.
Do not operate the humidifier when the water tank is
empty!Whenthewater reaches theminimumlevel,the
unitswitchesoffthenebulizerfunctionautomatically.The
emptyindicatorlightcomesonshowingtankisempty.
•Removethewatertankfromthebaseandunscrewthe
watertankcap(14).
• Makesurethatnoforeignobjectsareinthewater
tank.
• Fillthetankwithclean,coldwaterfromthetap(15).
Closethecapofthewatertanksecurely,placethewa-
tertankontothebase(16).Thewaterisnowrunning
fromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance
(17).
• Inserttheplugintothesocket(18)andswitchonthe
applianceusingtheon/offdial(19).Theemptyindi-
catorlightmaystayilluminatedforsomeseconds
untilthebaseisfilledwithwater.
Do not use additives
Water additives (ethereal/essential oils, fragrances,
eucalyptus, water conditioners, etc.) must not be used!
Evenasmallamountcancausecracksinthematerial.The
materialisn’tmadefortheuseofsuchadditives.Onedrop
isenoughtodamagethetankandasaconsequencethe
unit.Anyuseofsuchadditiveswillvoidthemanufacturer’s
warranty.
12
en
Operation AOS 7145
A) On/Off Dial and regulation of mist output
Turningtherotarydial clockwiseswitchesthe appliance
onandatthesametimeregulatesthemistoutputfrom
lowtohigh.
B) Hygrostat (setting the humidity level)
Thedesiredhumiditylevelcanbesetbyturningtherotary
switchclockwise.Arelativehumiditybetween40and60%
isrecommended.Youcanachievethislevelbyrotatingthe
switchuntilitisroughlyintheverticalposition.Theaccu-
racyofmeasurementis+/-5%.Theunitwill switchoff
whenthemoisturelevelexceedsthedesiredsetting.The
appliancedoesnotswitchoffiftheswitchisturnedallthe
waytotheright.This activates thecontinuousoperation
function.
C) Empty indicator (red)
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewa-
tertankisempty.Theredemptyindicatorisilluminated
(symbolC).Pleasereadthechapter«Fillingthetank»for
moreinformation.TheredsymbolCmaystayilluminated
forsomesecondswitharefilledtankuntilthebaseisfilled
withwater.
A
B
C
13
en
Operation AOS 7147
A) On/Off Button
YoucanswitchtheunitonoroffbypressingbuttonA.This
buttonisalsousedtoresetthecleaningindicatorlight(by
holdingdown).
B) Hygrostat (setting the humidity level)
BypressingbuttonByoucansetthedesiredhumiditylevel
from30%to80%orCO(continuousoperation).Arelative
humiditybetween40and60%isrecommended.Theac-
curacyofmeasurementis+/-5%.Theunitwillswitchoff
whenthemoisturelevelexceedsthedesiredsetting.During
selectionthetargetvalueisdisplayed(symbol DESIRED) . 
Thedisplaywillautomaticallyshowthecurrentvalueafter
afewseconds(symbol CURRENT).
C) Timer
Using button C, the operation time can be set adjusta-
blebetween1and8hoursorCO(continuousoperation).
Symbol Gshowstheoperatingperiodthathasbeenset
(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywillautomati-
callyshowthecurrenthumidityafterafewseconds.
D) Mist output (regulating mist output)
ByrepeatedlypressingbuttonDyoucancontrolthemist
output. Symbol Hshows whichofthethreelevels(low/
medium/high)youhaveselected.
E) Operation with pre-heating (warm mist)
ButtonEisusedforswitchingthepre-heatingonandoff
(symbol Ilightsup).Asaresult,thewaterispre-heated
toatemperatureof176°F(80°C)beforeenteringthe
nebulizerspace.Ittakesapprox.10to15minutesforthe
waterinthebasetowarmup.Themistnowleavesthe
humidifieratapleasanttemperatureof104°F(40°C).The
advantageofthisisthattheroomtemperaturedoesnot
dropand,inaddition,it significantly improvesthe water
qualitymaintenance.
F) Automatic mode and Sleep mode
Theautomaticandsleepmodescanbeactivatedbypres-
singbuttonF.Bypressingthebuttononce,theautomatic
functionisswitchedon(symbol Jappearsonthedisplay),
maintainingtheoptimumhumiditysubjecttothetempera-
ture.Controltakesplacebymeansofoutputquantityand
pre-settargetvalue.Bypressingthebuttontwice,thesleep
functionisswitchedon(symbol Kappearsonthedisplay),
thetargethumidityis50–65%;theoperationtimeisset
at6hoursandtheheatingisswitchedon.Inaddition,the
outputquantityisalsocontrolledsubjecttothedifference
betweenthetargetvalueandtheactualvalue.
Thehygrostatandmistoutputsettingscannotbechanged
ineithermode.IfthebuttonsBorDarepressed,theunit
willnolongerbeinautoorsleepmode.
G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewater
tankisempty.Theemptyindicatorisilluminated(symbolL).
Pleasereadthechapter«Fillingthetank»formoreinforma-
tion.ThesymbolLmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicator
IfsymbolM«CLEAN»appearsonthedisplay,theappliance
shouldbecleanedasrecommendedbythemanufacturer.
Thissymbolcomesonautomaticallyevery2weeks,de-
pendingonthelevelofuse.The display can be reset by
holding down button A until the light disappears.
D
E
F
H
I
J
L
A
B
C
G
K
M
14
en
ACID
23
22
21
20
Cleaning/Maintenance
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Caution – risk of electric shock and
damage of the product!
• Switchofftheappliance(20)andunplugitfromthe
socketbeforecleaningit(21).
• Cleanthewatertankandthebaseregularly.Usewater
only,nodetergents(22).
• UseAIR-O-SWISSEZCalcustomcleaninganddescaling
agentonlytoremovedepositsfromthemembranere-
gularly(23).ThereisasampleofEZCalincludedinthe
packagingofyourhumidifier.Instructionsforusingare
onthepacket.Onlyuse1packetfor32ozofwater.Do
notchangetheratio.DoNOTruntheunitwhenusing
EZCal.Thiscancausedamagetotheproductandvoids
thewarranty.Thoroughlyrinsethebasewithtapwater
afterusingEZCalandmakesurenoEZCalresidues
remaininthebase.
EZCalfromAIR-O-SWISSistheonlyrecommen-
dedcleaninganddescalingsolution.DoNOTuse
anyothercleaningsolutionssinceitcandamage
theproduct.Anyuseofcleaningsolutionsapart
fromEZCalwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater
(24)!
• AOS7147:Thecleaningindicatorstillappearsonthe
displayaftercleaning.ToresetitholddowntheON/OFF
buttonuntilthecleanlightdisappears.
• Cleantheinnerpartswithasoftcloth.Donotuseany
solventsoraggressivecleaningagentstocleanthe
appliance(25).
25
24
15
en
• Onlyusethebrushtocleanthemembrane.Thisshould
bedoneonceaweek.Onlyusethesoft-bristleportion
ofthebrush(26).
• Changethewaterinthetankatleastonceaweekif
waterisstandingformorethanaweek.
• Toremovethemistoutlet(27):Twistthemistoutletto
eithertherightortheleft.Alignthearrowonthemist
outletwiththearrowontheringaroundthemistoutlet.
Onlyonesetofarrowsonmistoutletandringwill
align.Pulluponthemistoutletoncethearrowsare
aligned.
Water quality maintenance
TheAIR-O-SWISSHydro Stick 7017keepsAIR-O-SWISS
humidifiersoperatingattheirhighestlevelbetweenrec-
ommendedcleanings*.Goodforoneyear,theHydroStick
ensuresthehumidifier’sfunctionalitywhileprovidingfresh
humidificationperformance.
Itstarts to work assoonas it comesintocontact with
water,eveniftheunitisturnedoff.TheHydroStickshould
bechanged everyyear. Lookat picture 28 fortheposi-
tionoftheHydroStickinthebasepartoftheunit.Donot
touchthewaterinthebaseduringoperation!Switchoffthe
unitfirst.Contactyourlocalretailerorcheckourwebsite
www.airoswiss.net for reorder information.The replace-
mentHydroStickcomeswithametallicclipwhichisnot
neededfortheplacementinthisproducttype.
*Refertothecleaninginstructionsinthismanual.
Lifecycle Indicator
Yourappliancecomeswithalifecycleindicatorforchanging
theHydroStick.Toremindyourselfof whenyouputthe
HydroStickintooperation,pleasecrossthecurrentmonth
onthestampandwritethecurrentyearonthelinepro-
vided(29).
26
28
29
27
16
en
30
31
•Turntheplasticcupandcartridgeoverandshakeuntil
allgranulesareinthecartridge(37).
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(38)andretainforfutureuse(the
refillgranulesconsistsof3refillbags)(39).
•Closethecartridge(40).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(43).Thegranuleshaveto
absorbwatertoreachmaximumperformance.Ifthe
cartridgeissoakedinthetank,makesuretoexchange
thewaterandemptythewaterfromthebasebefore
usingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).
•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(45).
Placinggranulesinthecenterofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge
•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counter-clockwise(31).Important:doNOTdisposeof
thewatertankcap!
• Throwthewholecartridgeintothewaste(41).
•Unpackthenewcartridge(42).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(43).Thegranuleshaveto
absorbwatertoreachmaximumperformance.Ifthe
cartridgeissoakedinthetank,makesuretoexchange
thewaterandemptythewaterfromthebasebefore
usingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).Close
tankcapwellandplacethetankonthemainbody
(45).
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
The water tank is equipped with a demineralization cart-
ridge.Thiscartridgehastobereplacedevery2–3months.
Ifthewaterisveryhard,itmaybenecessarytoreplacethe
cartridgeearlier.Whitedustaroundthedeviceisasuresign
thatthecartridgeneedsreplacing.Ifwhiteresiduestillforms
aroundthedeviceafteranewcartridgehasbeeninserted,
pleasemakesurethatthewateryouareusingisuntreated.
Ifthewaterflows
throughadecalcificationsystem–suchas
anionexchanger–(sodiumisaddedtoremovecalcium)in
thebuildingbeforeitisusedinthehumidifier,saltcanpre-
cipitateaswhitedustaroundthedevice.Thedemineralization
cartridgeorthe granules must beexchangedat the latest
after6monthsortheunitdoesnotreachitsfullperformance
anymore.
Option A: replace the granules
•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counter-clockwise(31).Important:doNOTdisposeof
thewatertankcap!
•Openthecartridge(32).
•Throwthecontentintothewaste(Attention!Disposed
granulescanmakethefloorslippery!)(33).
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(34).
•Pourthecontentsofonerefillgranulesbagintothe
plasticcupthatisincludedwiththerefillgranulespa-
ckaging(35).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(36).
32 33
17
en
44
34 35
36
37
38
39
41
43
40
42 45
18
en
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Legal notice
ThehumidifieriscUL-listed.
Subjecttotechnicalchange.Theinstructionsforuseare
protectedbycopyright©PLASTONAG.
Accessories
Contact your local retailer or check our website www.
airoswiss.netforre-orderinformation.
Customer Service
CustomerService(USA)1-800-336-0326
www.airoswiss.net
Technical data AOS 7145
Electricalvoltage 120V/60Hz
Powerconsumptionupto 45W
Humidityoutputupto 3gallons/24h
Suitableforroomsupto 600sqft/55m
2
Dimensions(LxWxH) 9.5x10.3x12.2in
24x26x31cm
Weight(empty) 6.6lbs/3kg
Accessories AOS7531Demineralizationcartridge
AOS7017HydroStick
Technical data AOS 7147
Electricalvoltage 120V/60Hz
Powerconsumptionupto 40W/(125W*)
Humidityoutputupto 3.5gallons/24h*
Suitableforroomsupto 650sqft/60m
2
Dimensions(LxWxH) 9.5x10.3x12.2in
24x26x31cm
Weight(empty) 6.6lbs/3kg
Accessories AOS7531Demineralizationcartridge
AOS7017HydroStick
*whenusedwithpre-heatingto176°F(80°C)
Troubleshooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal
Demineralizationcartridgeexhausted Replacecartridgeorgranules
Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow
withgranules themaway
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min.
thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush
Unitrunningintermittently Replacedemineralizationcartridgeorgranules
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste
19
en
General Humidifier Questions
Q.Why isn’t there enough moisture in my room?
A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropif
moistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the
unit is running?
A. a) Byleavingthedooropen,thisallowsmoistureto
leavetheroomandgointootherareasofthehouse.
Ifyouwouldlikethemoisturetostaywithinone
specificroomyoushouldconsiderclosingthedoor
whiletheunitisrunning.
A. b) Wood,leather,carpet,curtains,andothertypesof
fabricsoakupalotofmoisture,thusnotleaving
enoughmoisturefortheair.Ifthewindowisleft
open,thenthisallowsmoisturetoescapetheroom.
Anotherfactorisalotoftimestheunitisplacednext
toaheatingdevice.Theideaisthattheairblowing
intotheroomwillquicklyplacemoisturearoundthe
room.Unfortunately,thisconceptdoesnotwork
becausethehotaircomingoutofaventwillsoak
upmostofthemoisture,andnoneoftheairwithin
theroomwillreceiveany.
Q.How much moisture do I need in my room?
A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much
humidity?
A. Dryaircancausedryskin,staticelectricity,outoftune
musicalinstruments,increasedlevelsofdust(dryair
causesdusttorise),damagetowoodenobjects(dry
outandeventuallycracksappear),discomfort,sick-
ness,anddriesoutnasalmembranes.
Over-humidifyingtheaircancausemoldandwallpaper
topeel.
Q.Why do I need a humidifier when I can just open
my window?
A. Themoisturelevelwithintheoutsideairisnothigh
enoughtohumidifyaroom.Thecoldertheairtheless
moistureitiscapabletohold,andthemoretheairis
heatedupthepercentageofrelativehumidityislower.
Relativehumiditymeanstheamountofwatervaporin
theair,comparedtotheamounttheaircouldholdifit
wastotallysaturated.Thedifferenceishigherbetween
outsideandinsidetemperatures;morehumidification
isneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?
A. Theunitshouldbefree-standingandnotclosetoa
wall,window,door,orthermalbridgesothatairmay
circulatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization
cartridge cap?
A. Thosedirectionsarethereincaseyoudecidetouse
therefilloptiontoreplacethegranules;thepurposeis
forhowtoopenandclosethecap.Ifyoudidopenthe
capbeforeplacingitinthewatertank,youwillmost
likelynoticethattherearegranulesinthewatertank
andthebaseoftheunit.Immediatelyturnofftheunit,
andemptythewateroutofthebaseandthewater
tank.Beginremovingallgranulesfrombaseandwater
tank.Usebrushtocleanaroundmembrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q.I just replaced my cartridge, and the contents and
water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreven
thegranules,arereplaced.Thisdoesnotoccurwithall
replacementcartridgesorgranules,andisareactionof
watercontentandtheUltrasonicvibrations.Thisisnot
anindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far
may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybe
filledallthewaytothetop.
Q.What is the purpose of the demineralization cart-
ridge (DMC)?
A. TheDMCremovesmineralsfromthewatertoprevent
whitedust.Thecontentsofthecartridgeneedtobeso-
akedfor24hrspriortofirstusingtheunitsothatthey
mayfullyexpandandremovemineralsfromthewater.
ThecontentsoftheDMChavealifeof2–3months.
Thecartridgemayneedtobereplacedmoreoften
dependingonwaterhardnessandhowoftentheunit
isused.AnindicationofwhentheDMCneedstobe
changedcanbewhitedustorreducedamountofmist
output.
Q.Is it ok to use distilled water with the unit?
A. Forbestresultswithyourultrasonichumidifieruse
distilledorreverse-osmosiswaterandremovethe
demineralizationcartridge.
Q.I just replaced the contents of the cartridge and
now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddle
ofthecartridge.Placinggranulesinthemiddleofthe
DMCallowsthemtoescapeintheunit.Immediately
turnofftheunit,andemptythewateroutofthebase
andthewatertank.Beginremovingallgranules
frombaseandwatertank.Usebrushtocleanaround
membrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidity
intotheair.Becauseofthis,thecarpetingorwoodfloor
surroundingtheunitmaybecomedamp.Iftheunitis
20
en
placedatleast3feetoffthefloor,themistwillhavethe
opportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.
A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donot
pourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unit
A.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess.
Solve the problem:
•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoaked
inthewatertank,thewaterinthetankandthebase
needstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter1-2
monthswhenyouuseveryhardwater(forsofterwater
after2-3months).Nomatterhowhardyourwater
is,exchangethecartridgeattheverylatestafter6
months.
•Don’tusewaterfromapre-installedwatersoftener,
orsodiuminsteadofcalciumwillbeemittedfromthe
unit.Usedistilledwaterinsteadandremovethedemi-
neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterand
removethedemineralizationcartridge.
•UseReverse-Osmosiswater(R-Owater)insteadof
distilledwaterandremovethedemineralizationcart-
ridge.
•Cleaning light is illuminated (digital models)
Switchofftheunitandunplugit.Emptythewaterin
thebase.Rinsethebasewithhot/cleanwater.Donot
submergethebase!Visuallyinspectthebasefordirtor
mineralbuildup.Ifsoftwaterisuseddecalcifyingthe
unitevery4weekswithEZCalissuggested.Ifhard
waterisusedtheunitshouldbedecalcifiedevery2
weeks.Donotforgettoresetthecleanlightafterreset-
tingtheunit.
Q.Reset cleaning light (digital models)
A. Thecleaninglightdoesnotautomaticallyreset.Hold
downthepowerbutton(buttonAininstructionmanual)
untilthelightstopsflashing.Thelightautomatically
comesonapprox.after14daysofpluggingintheunit.
Q.The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmost
areoffby+/-5%.Plusthehumiditylevelisnotthe
sameinthewholeroom.Theaircirculationisdifferent
ineverycorneroftheroom.Theunitshouldnotbe
placednearaheatingventoraradiatorastheheatwill
absorballofthemoisture.
Q.Humidity level is not changing or does not reach
the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceper
day,theunitisworkingproperlyandtheclimaticcon-
ditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:
•aircirculationisveryhigh(airisfullyexchangedse-
veraltimesperday–thehumidifierneedstostartsits
workfromscratch)
•insulationofhome(seeaircirculation)
•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–high-risebuil-
dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitis
verycoldoutsidedon’topenthewindowmorethan2
timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinside
temperature–thecoldertheairthelessmoistureit
iscapabletoholdandthemoretheairisheatedup
theloweristhepercentageofrelativehumidity(=the
amountofwatervaporintheair,comparedtothe
amounttheaircouldholdifitwastotallysaturated)
•positionoftheunit-ifitisplacedclosetoadoor,win-
doworairvent.Thisincreasestheaircirculation.
Q.Tank is leaking
A. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunder
thewarranty.Pleasecontacttheretailertheunitwas
purchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mist
A. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbe
playedwith.
Q.No mist / unit is not working / empty indicator
keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthrough
thedemineralizationcartridge(attachedtothewater
tankcap).Ifthewatertankisfullbutthereisonlylittle
waterinthebaseitindicatesthatthewaterisnow
flowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutof
theunit.
•Iftheunitisnotworkingandtheemptylightisnot
flashingyoumighthavesetthedesiredhumiditytoo
lowandthecurrenthumiditylevelintheroomishig-
her.Thatiswhytheunitswitchesoffautomatically.
•Iftheemptyindicatorkeepsflashingandthetankis
full,thewaterisnotflowingthroughthecartridge.
Exchangethecartridgeorthegranulesinthecartridge
after2-3months,inareaswithhardwaterexchange
thecartridgeafter1-2months.However,thedemi-
neralizationcartridgeandorthegranulesmustbe
exchangedatthelatestafter6monthsortheunitdoes
notreachitsfullperformanceanymore
•Ifthegranulesarenew,seethefollowinginstructions:
•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwater
tofilterthroughthecartridgeandintothebase.Next,
pleaseremove2tablespoonsofgranulesfromthe
cartridge,andthrowthemaway.Whentherearetoo
manygranulesinthecartridgeitdoesnotallowwater
toflowfromthetanktothebase.
/