PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
Important safety instructions
• Priortousingtheappliance,readthroughthe
instructionsforcompleteuseandretaininasafe
placeforlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithin
thespecifiedtechnicaldata.Improperusecanbe
hazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrent(AC)with
voltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociated
withtheusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyarenearthe
humidifier(image1).
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunction,afterthe
appliancehasbeendropped(3)ordamagedinany
otherway.
• Repairsofelectricalappliancesareonlytobemadeby
qualifiedserviceengineers(4).Improperrepairwork
cancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).
• Do not place the appliance directly on the flooror
nexttoaheatingvent(6).
• Ifthemistcomesincontactwiththefloorpriorto
evaporating,thefloorsurfacecanbecomedamaged.
Wedonotacceptanyliabilityfordamagesinthecase
ofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).
• Alwaysunplugwhennotinuse.
• Onlyoperatethehumidifierwhenitiscompletely
assembled.
• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/
dismantlingofindividualpartsandbeforemovingthe
appliance.
• Donottouchthewaterinthebaseduringoperation
becauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonot
coverwiththrowrugs.Arrangecordsothatitwillnot
betrippedover.
• Neverpulltheplugfromtheoutletbythecableorwith
wethands.
• Donotusetheappliancewherecombustiblegasesor
vaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,
inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.
• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockor
damagetotheappliance.Donotblockairoutletsor
intakes.
• Donotpourwaterintothemistoutletoftheappliance.
• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugis
intendedtofitinapolarizedoutletonlyoneway.Ifthe
plugdoesnotfitfullyintheoutlet,reversetheplug.Ifit
stilldoesnotfit,contactaqualifiedelectrician.DONOT
attempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andthe
ACoutletmaycauseoverheatingandadistortion
oftheplug.Contactaqualifiedelectriciantoreplace
looseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Donotsubmergethemainbodyinwaterorother
liquids.
• Disconnectpowersupplybeforeservicing.
• Personswhoarenotfamiliarwiththeinstructions
foruse,aswellaschildrenandpersonsunderthe
influenceofmedication,alcohol,ordrugsarenot
permittedtooperatetheappliance,orareonly
permittedtooperateitundersupervision.
• Toprotecthealth safetyandproper humidifierfunction
useonlyclean,contamination-free,cold,freshtapwa-
terinyourhumidifier.Ifyourwatersourceiscontam-
inatedorifyouareuncertainofitssafetyusedistilled
water.Inaddition,itisadvisedtoclean and maintain
your humidifierinatimelymanneras instructed in
this manual.
• Theuseofwateradditives,suchasethereal/essential
oils,fragrances,eucalyptus,waterconditionersetc.,
damagesthetankmaterialandasaconsequence
thewholeunit.Anyuseofsuchadditiveswillvoidthe
manufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehigh
frequencyvibrations.
7
en
5
1
3
1ft
4ft
3ft
7
96
2
4
8
8
en
Foreword
Congratulations on choosing the Ultrasonic Humidifier
AIR-O-SWISS 7133!
Did you know that dry room air:
• Causesthemembranesinyourrespiratorysystemto
dryout,andalsocauseschappedlipsandstinging
eyes?
• Encouragesinfectionsandillnessesofrespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,carpets
andplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?
• Detunesmusicalinstruments?
General information
A comfortable atmosphere indoors is reached with a re-
lative humidity level between 40 and 60%.Yourhumidi-
fier automatically controls the humidity level according
todesired setting. Iftheairistoodry,thehumidifier will
automaticallyswitchon.Assoonasthedesiredhumidity
levelisreached,itwillswitchoff.
Unpacking
• Carefullyremovethehumidifierfromthebox.Place
yourhandsunderneaththeproducttopullitoutofthe
box(10).
• Warning:Donottaketheunitoutoftheboxbypulling
uponthetankhandle-basemayfallandwillbeda-
maged(11).
• Warning:Themistoutletispackedinaredbaginside
theboxinsert.Makesurethatyouremovethemist
outletfromthepackaging(12).
• Removetheplasticbagfromthehumidifier.
• Observetheinformationgivenontheratingplateabout
thevoltage.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotusethehumidifierallyearround.
10
11
12
9
en
Setting up
Findingtheideallocationforyourunit:
• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureof
themistcandamagethefloorsurface(6)(seeSafety
Instructions).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyatplants,
furniture,orotherobjects(13).Keepdistanceofat
least20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(14).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
• Onaveragethedemineralizationcartridgeshould
bereplacedevery2–3monthsdependingonyour
waterhardness.Someareasmayneedtoreplacethe
cartridgesooner,somemaylastlonger.Thecartridge
mustbeexchangedatthelatestafter6monthsorthe
unitdoesnotreachitsfullperformanceanymore.
 See«Replacementofthedemineralizationcartridge».
• Readtheinstructionsunder«FillingtheTank»for
addingwaterinthehumidifier(15and16).
• Placethewatertankontothebase.
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offdial(19).
• About10to15minutesafteritisswitchedonthede-
vicewillreachitsfulloutputlevel.
• Makesurethatthecableisnotpinchedanywhere(9).
Donotoperatethehumidifierifthecableisdamaged
(2).
Membrane
Controlpanel
Air inlet
Mistoutlet(rotating)
Demineralizationcartridge
Water tank
Evaporationchamber
Brush
Waterbase
Powerplug
Water level sensor
Mainbody
Description of the appliance
Watertankcap
Hydro Stick
24 h
14
13
10
en
17
18
16
15
Filling the tank
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Toprotecthealth safetyand proper humidi-
fierfunctionuseonlyclean,contamination-free,
cold,freshtapwaterinyourhumidifier.Ifyour
watersourceiscontaminatedorifyouareuncertainofits
safetyusedistilledwater.
Do not operate the humidifier when the water tank is
empty!Whenthewaterreachestheminimumlevel,theunit
switchesoffthenebulizerfunctionautomatically.Thered
lightcomesonindicatingtankisempty.
•Removethewatertankfromthebaseandunscrewthe
watertankcap(15).Caution:themistoutletisloose!
• Makesurethatnoforeignobjectsareinthewater
tank.
• Fillthetankwithclean,coldwaterfromthetap(16).
Closethecapofthewatertanksecurely,placethewa-
tertankontothebase(17).Thewaterisnowrunning
fromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance
(18).
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offdial(19).Theredempty
indicatorlightmaystayilluminatedforsomeseconds
untilthebaseisfilledwithwater.Thenthegreenlight
comeson.
Do not use additives
Water additives (ethereal/essential oils, fragrances,
eucalyptus, water conditioners, etc.) must not be used!
Evenasmallamountcancausecracksinthematerial.The
materialisn’tmadefortheuseofsuchadditives.Onedrop
isenoughtodamagethetankandasaconsequencethe
unit.Anyuseofsuchadditiveswillvoidthemanufacturer’s
warranty.
O
I
19
11
en
C) Operation with water pre-heating
(warm mist)
ButtonCisusedforswitchingthepre-heatingonandoff
(symbol Dlightsup).Asaresult,thewaterispre-heated
to a temperature of 176°F(80 °C) before entering the
nebulizerspace.Ittakesapprox.10to15minutesforthe
water in the base to warm up.The mist now leaves the
humidifieratapleasanttemperatureof104°F(40°C).The
advantage ofthisisthattheroomtemperaturedoesnot
drop and, in addition, it significantly improves the water
qualitymaintenance.
D) Pre-heating indicator (On/Off)
E) Empty indicator
Thewaterlevel iseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewater
tankisempty.Theemptyindicatorisilluminated(symbolE).
Pleasereadthechapter«Fillingthetank»formoreinforma-
tion.ThesymbolEmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
A) On-off dial and regulation
of mist output
Turningtheright-handrotarydialclockwiseswitchesthe
applianceonandatthesametimeregulatesthemistout-
putfromlowtohigh.
B) Hygrostat (setting the humidity level)
Thedesiredhumiditylevelcanbesetbyturningtheleft-
handrotarydialclockwise.Arelativehumidityofbetween
40%and60%isrecommended.Youcanachievethislevel
byrotatingthedialuntilitisroughlyinthe verticalposi-
tion.Themeasurementaccuracyis+/-5%.Assoonasthe
humidityexceedsthedesiredsetting,theapplianceswit-
ches off.The appliance doesnot switchoffifthe dial is
turnedallthewaytotherightasfarasthearrowsymbol.
Thisactivatesthecontinuousoperationfunction.
Operation AOS 7133
O
I
A
CB
D
E
12
en
ACID
30 min
140°F / 60°C
22
2521
24
Cleaning/Maintenance
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Caution – risk of electric shock and
damage of the product!
• Switchofftheapplianceandunplugitfromthesocket
beforecleaningit(20).
• Cleanthewatertankandthebaseregularly.Usewater
only,nodetergents(21).
• UseAIR-O-SWISSEZCalcustomcleaninganddesca-
lingagentonlytoremovedepositsfromthemembrane
regularly(22and23).ThereisasampleofEZCalin-
cludedinthepackagingofyourhumidifier.Instructions
forusingareonthepacket.Onlyuse1packetfor32
ozofwater.Donotchangetheratio.DoNOTrunthe
unitwhenusingEZCal.Thiscancausedamagetothe
productandvoidsthewarranty.Thoroughlyrinsethe
basewithtapwaterafterusingEZCalandmakesure
noEZCalresiduesremaininthebase.
23
O
I
20
26
13
en
27
Water quality maintenance
TheAIR-O-SWISSHydro Stick7017 keepsAIR-O-SWISS
humidifiersoperatingat their highestlevel betweenrec-
ommendedcleanings*.Goodforoneyear,theHydroStick
ensuresthehumidifier’sfunctionalitywhileprovidingfresh
humidificationperformance.
Itstarts toworkas soonasit comesinto contactwith
water,eveniftheunitisturnedoff.TheHydroStickshould
bechanged everyyear.Lookat picture27for theposi-
tionoftheHydroStickinthebasepartoftheunit.Donot
touchthewaterinthebaseduringoperation!Switchoffthe
unitfirst.Contactyourlocalretailerorcheckourwebsite
www.airoswiss.net for reorder information.The replace-
mentHydroStickcomeswithametallicclipwhichisnot
neededfortheplacementinthisproducttype.
*Refertothecleaninginstructionsinthismanual.
Lifecycle Indicator
Yourappliancecomeswithalifecycleindicatorforchanging
theHydroStick.Toremind yourself of when you put the
HydroStickintooperation,pleasecrossthecurrentmonth
onthestampandwritethecurrentyearonthelineprovid-
ed(28).
28
EZCalfromAIR-O-SWISSistheonlyrecommen-
dedcleaninganddescalingsolution.DoNOTuse
any other cleaning solutions since it can damage
theproduct.Anyuseofcleaningsolutionsapart
fromEZCalwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater
(24)!
• Cleantheinnerpartswithasoftcloth.Donotuseany
solvents or aggressive cleaning agents to clean the
appliance(25).
• Onlyusethebrushtocleanthemembrane.Thisshould
bedoneonceaweek.Onlyusethesoft-bristleportion
ofthebrush(26).
• Changethewaterinthetankatleastonceaweekif
waterisstandingformorethanaweek.
14
en
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Thewatertankisequippedwithademineralizationcartridge.
This cartridge has to be replaced every 2 – 3 months. If
thewaterisveryhard,itmaybenecessarytoreplacethe
cartridgeearlier.Whitedustaroundthedeviceisasuresign
that the cartridge needs replacing.Please note white dust
isnotharmful.Ifwhiteresiduestillformsaroundthedevice
afteranewcartridgehasbeeninserted,pleasemakesure
thatthewateryouareusingisuntreated.Ifthewaterflows
throughadecalcificationsystem–suchasanionexchanger
–(sodiumisaddedtoremovecalcium)inthebuildingbefore
itisusedinthehumidifier,saltcanprecipitateaswhitedust
aroundthedevice.Thedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6monthsor
theunitdoesnotreachitsfullperformanceanymore.
Option A: replace the resin
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counter-clockwise(30).Important:doNOTdisposeof
thewatertankcap!
•Openthecartridge(31).
•Throwthecontentintothewaste(Attention!Disposed
resincanmakethefloorslippery!)(32).
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(33).
•Pourthecontentsofonerefillresinbagintotheplastic
cupthatisincludedwiththerefillresinpackaging(34).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(35).
•Turntheplasticcupandcartridgeoverandshakeuntil
allresinisinthecartridge(36).
29
30
31 32
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(37)andretainforfutureuse(the
refillresinconsistsof3refillbags)(38).
•Closethecartridge(39).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).
•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(44).
Placinggranulesinthe center ofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counter-clockwise(30).Important:doNOTdisposeof
thewatertankcap!
• Throwthewholecartridgeintothewaste(40).
•Unpackthenewcartridge(41).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).Close
tankcapwellandplacethetankonthemainbody
(44).
15
en
44
4335
36 40
24 h
42
41
33 34 37
38 39
16
en
Technical data
Electricalvoltage 120V/60Hz
Powerconsumptionupto 45W/(140W*)
Humidityoutputupto 3.5gallons/24h*
Suitableforroomsupto 650sqft/60m
2
Dimensions(LxWxH) 15x8.7x13.8in
38x22x35cm
Weight(empty) 7.7lbs/3.5kg
Accessories AOS7531Demineralizationcartridge
AOS7017HydroStick
*whenusedwithpre-heatingto176°F(80°C)
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Legal notice
ThehumidifieriscUL-listed.
Subjecttotechnicalchange.The instructions foruseare
protectedbycopyright©PLASTONAG.
Accessories
Contact your local retailer or check our website www.
airoswiss.netforre-orderinformation.
Customer Service
CustomerService(USA)1-800-336-0326
www.airoswiss.net
Trouble shooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Empty-lightred) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal
DMCexhausted Replacecartridgeorgranules
DMCoverfilledwithgranules Takeout2tablespoonsofgranulesandthrow
them away
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min.
thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush
Unit running intermittently Replacedemineralizationcartridgeorgranules
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste
17
en
General Humidifier Questions
Q. Why isn’t there enough moisture in my room?
A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropif
moistureisnotconstantlyaddedtotheair.
Q. Do you leave your door open or closed when the
unit is running?
A. a) Byleavingthedooropen,thisallowsmoistureto
leavetheroomandgointootherareasofthehouse.
Ifyouwouldlikethemoisturetostaywithinone
specificroomyoushouldconsiderclosingthedoor
whiletheunitisrunning.
A. b) Wood,leather,carpet,curtains,andothertypesof
fabricsoakupalotofmoisture,thusnotleavingen-
oughmoisturefortheair.Ifthewindowisleftopen,
thenthisallowsmoisturetoescapetheroom.Ano-
therfactorisalotoftimestheunitisplacednextto
aheatingdevice.Theideaisthattheairblowing
intotheroomwillquicklyplacemoisturearoundthe
room.Unfortunately,thisconceptdoesnotwork
becausethehotaircomingoutofaventwillsoak
upmostofthemoisture,andnoneoftheairwithin
theroomwillreceiveany.
Q. How much moisture do I need in my room?
A. Suggestedhumiditylevelsarebetween40–60%.
Q. What are the effects of too little or too much
humidity?
A. Dryaircancausedryskin,staticelectricity,outoftune
musicalinstruments,increasedlevelsofdust(dryair
causesdusttorise),damagetowoodenobjects(dry
outandeventuallycracksappear),discomfort,sick-
ness,anddriesoutnasalmembranes.
Over-humidifyingtheaircancausemoldandwallpaper
topeel.
Q. Why do I need a humidifier when I can just open
my window?
A. Themoisturelevelwithintheoutsideairisnothigh
enoughtohumidifyaroom.Thecoldertheairtheless
moistureitiscapabletohold,andthemoretheairis
heatedupthepercentageofrelativehumidityislower.
Relativehumiditymeanstheamountofwatervaporin
theair,comparedtotheamounttheaircouldholdifit
wastotallysaturated.Thedifferenceishigherbetween
outsideandinsidetemperatures;morehumidification
isneededbecauseofthedryairintheroom.
Q. Where should I place my humidifier?
A. Theunitshouldbefree-standingandnotclosetoa
wall,window,door,orthermalbridgesothatairmay
circulatearoundtheunit.
Ultrasonic Frequent Questions
Q. Why does it say open/close on the demineralization
cartridge cap?
A. Thosedirectionsarethereincaseyoudecidetouse
therefilloptiontoreplacethegranules;thepurposeis
forhowtoopenandclosethecap.Ifyoudidopenthe
capbeforeplacingitinthewatertank,youwillmost
likely notice that there are granules in the water tank
andthebaseoftheunit.Immediatelyturnofftheunit,
andemptythewateroutofthebaseandthewater
tank.Beginremovingallgranulesfrombaseandwater
tank.Usebrushtocleanaroundmembrane.
Caution:Donotdisposeofgranulesinsink!Used
granules must go in waste!
Q. I just replaced my cartridge, and the contents and
water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreven
thegranules,arereplaced.Thisdoesnotoccurwithall
replacementcartridgesorgranules,andisareactionof
watercontentandtheUltrasonicvibrations.Thisisnot
anindicatortoreplacethecartridge.
Q. There is no fill-line on the water tank, how far
may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybe
filledallthewaytothetop.
Q. What is the purpose of the demineralization
cartridge (DMC)?
A. TheDMCremovesmineralsfromthewatertoprevent
whitedust.Thecontentsofthecartridgeneedtobeso-
akedfor24hrspriortofirstusingtheunitsothatthey
mayfullyexpandandremovemineralsfromthewater.
ThecontentsoftheDMChavealifeof2–3months.
Thecartridgemayneedtobereplacedmoreoften
dependingonwaterhardnessandhowoftentheunit
isused.AnindicationofwhentheDMCneedstobe
changedcanbewhitedustorreducedamountofmist
output.
Q. Is it ok to use distilled water with the unit?
A. Forbestresultswithyourultrasonichumidifieruse
distilled or reverse-osmosis water and remove the
demineralizationcartridge.
Q. I just replaced the contents of the cartridge and
now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddle
ofthecartridge.Placinggranulesinthemiddleofthe
DMCallowsthemtoescapeintheunit.Immediately
turnofftheunit,andemptythewateroutofthebase
andthewatertank.Beginremovingallgranules
frombaseandwatertank.Usebrushtocleanaround
membrane.
Caution:Donotdisposeofgranulesinsink!Used
granules must go in waste!
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidity
intotheair.Becauseofthis,thecarpetingorwoodfloor
surroundingtheunitmaybecomedamp.Iftheunitis
18
en
placedatleast3feetoffthefloor,themistwillhavethe
opportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.
A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donot
pourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unit
A.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess.
Solve the problem:
•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoaked
inthewatertank,thewaterinthetankandthebase
needstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter1-2
monthswhenyouuseveryhardwater(forsofterwater
after2-3months).Nomatterhowhardyourwater
is,exchangethecartridgeattheverylatestafter6
months.
•Don’tusewaterfromapre-installedwatersoftener,
orsodiuminsteadofcalciumwillbeemittedfromthe
unit.Usedistilledwaterinsteadandremovethedemi-
neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterand
removethedemineralizationcartridge.
•UseReverse-Osmosiswater(R-Owater)insteadofdis-
tilledwaterandremovethedemineralizationcartridge.
Q. The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmost
areoffby+/-5%.Plusthehumiditylevelisnotthe
sameinthewholeroom.Theaircirculationisdifferent
ineverycorneroftheroom.Theunitshouldnotbe
placednearaheatingventoraradiatorastheheatwill
absorballofthemoisture.
Q.Humidity level is not changing or does not reach
the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceper
day,theunitisworkingproperlyandtheclimaticcon-
ditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:
•aircirculationisveryhigh(airisfullyexchangedse-
veraltimesperday–thehumidifierneedstostartsits
workfromscratch)
•insulationofhome(seeaircirculation)
•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–high-risebuil-
dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitis
verycoldoutsidedon’topenthewindowmorethan2
timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinside
temperature–thecoldertheairthelessmoistureit
iscapabletoholdandthemoretheairisheatedup
theloweristhepercentageofrelativehumidity(=the
amountofwatervaporintheair,comparedtothe
amounttheaircouldholdifitwastotallysaturated)
•positionoftheunit-ifitisplacedclosetoadoor,win-
doworairvent.Thisincreasestheaircirculation.
Q. Tank is leaking
A. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunder
thewarranty.Pleasecontacttheretailertheunitwas
purchasedfromincaseyourunitarrivesdamaged.
Q. Placing the face in the mist
A. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbe
playedwith.
Q. No mist / unit is not working / empty indicator
keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthrough
thedemineralizationcartridge(attachedtothewater
tankcap).Ifthewatertankisfullbutthereisonlylittle
waterinthebaseitindicatesthatthewaterisnow
flowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutof
theunit.
•Iftheunitisnotworkingandtheemptylightisnotflas-
hing you might have set the desired humidity too low
andthecurrenthumiditylevelintheroomishigher.
Thatiswhytheunitswitchesoffautomatically.
•Iftheemptyindicatorkeepsflashingandthetankis
full,thewaterisnotflowingthroughthecartridge.
Exchangethecartridgeorthegranulesinthecartridge
after2-3months,inareaswithhardwaterexchange
thecartridgeafter1-2months.However,thedemi-
neralizationcartridgeandorthegranulesmustbe
exchangedatthelatestafter6monthsortheunitdoes
notreachitsfullperformanceanymore
•Ifthegranulesarenew,seethefollowinginstructions:
•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwater
tofilterthroughthecartridgeandintothebase.Next,
pleaseremove2tablespoonsofgranulesfromthe
cartridge,andthrowthemaway.Whentherearetoo
many granules in the cartridge it does not allow water
toflowfromthetanktothebase.
Q. Water tank cap is too tight to unscrew
A. Thiscouldbeacauseoftheairpressurewithinthe
watertank.Depressthespringonthebottomofthe
watertankcaptoreleaseairfromthewatertank.
Continuetodothisuntilyouareabletounscrewthe
watertankcap.
Q. Unit is running intermittently.
A. Howlonghasitbeensincethecontentsofthe
cartridgewerereplaced?If2-3monthshavepassed,it
istimetoreplacethecontentsofthecartridge.
Howeverthedemineralizationcartridgeandorthegran-
ulesmustbeexchangedatthelatestafter6monthsor
theunitdoesnotreachitsfullperformanceanymore.
19
en
•Ifthecontentsofthecartridgewerejustreplacedthere
areprobablytoomanygranulesinthecartridge.Re-
move2tablespoonsofgranulesfromthecartridge.
Accessories
Q.Do I need to keep any parts before I replace the
demineralization cartridge?
A. Yes,alwayskeepthewatertankcap(thisisthepiece
thatattachesthedemineralizationcartridgetothe
watertank).
Q.What is the Hydro Stick and how long is it good
for?
A.TheAIR-O-SWISSHydroStickkeepshumidifiers
operatingattheirhighestlevelbetweenrecommended
cleanings*.Goodforoneyear,theHydroStickensures
thehumidifier’sfunctionalitywhileprovidingfresh
humidificationperformance.Itneedstobereplaced
onceayear.
*Refertothecleaninginstructionsinthismanual.
Q.Placement of the Hydro Stick
A.Pleaseseepicture27forinstructions.
Q.Replacement reminder
A.IneachHydroStickboxandonallthenewproducts
thereisaHydroSticklifecycleindicator.Checkthebox
ofthemonthwhenstartingtousetheHydroStickand
writetheyearonthelineindicated.Exchangeitafter
oneyear.
Q.What is EZCal?
A. ThereisasamplepacketofEZCalincludedinthe
packagingofyourhumidifier.EZCalisusedforcleaning
anddescalinganyoftheAIR-O-SWISShumidifiersand
cleansmineralbuild-up.EZCalistheonlyrecommen-
dedcleaninganddescalingsolution.DoNOTuseany
othercleaningsolutionssinceitcandamagethe
product.AnyuseofcleaningsolutionsapartfromEZCal
willvoidthewarranty.Instructionsforusingareonthe
packet.Onlyuse1packetfor32ozofwater.Donot
changetheratio.Itcanalsobeusedforotherhumidi-
fierbrands.Thoroughlyrinsethebasewithtapwater
andmakesurenoEZCalresiduesremaininthebase!
EZCalisavailableatselectedretailstoresandonline
www.airoswiss.net.
20
en
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Air-O-Swiss AOS 7133 Instructions For Use Manual

Category
Humidifiers
Type
Instructions For Use Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI