Air-O-Swiss U600 User manual

Category
Humidifiers
Type
User manual

This manual is also suitable for

Air-O-Swiss U600 helps you to maintain a pleasant and healthy room climate by increasing the humidity level in the air to counteract dry air, which can cause a range of health issues including dry and irritated skin and respiratory issues. The device is equipped with the latest technology and features to deliver effective and efficient humidification for rooms up to 25 m2 (270 ft2). Air-O-Swiss U600 features include:

  • Adjustable mist output: Allows you to customize the humidity level to your desired comfort level.
  • Automatic humidity control: Maintains the desired humidity level by automatically adjusting the mist output.

Air-O-Swiss U600 helps you to maintain a pleasant and healthy room climate by increasing the humidity level in the air to counteract dry air, which can cause a range of health issues including dry and irritated skin and respiratory issues. The device is equipped with the latest technology and features to deliver effective and efficient humidification for rooms up to 25 m2 (270 ft2). Air-O-Swiss U600 features include:

  • Adjustable mist output: Allows you to customize the humidity level to your desired comfort level.
  • Automatic humidity control: Maintains the desired humidity level by automatically adjusting the mist output.
PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y
GUARDE TODAS
LAS INSTRUCCIONES!
AOS U600 / U650
Service Questions: Contact Air-O-Swiss at (800) 336-0326
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com
Service Questions: Contact Air-O-Swiss at (800) 336-0326
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com
3
Instructions for use (5 – 22)
en
Instructions d’utilisation (23 – 40)
a
fr
Instrucciones para el uso (41 – 57)
a
es
4
5
en
Instructions for use
6
en
Important safety instructions
• Priortousingtheappliance,readthroughthe
instructionsforcompleteuseandretaininasafe
placeforlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithin
thespecifiedtechnicaldata.Improperusecanbe
hazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrent(AC)with
voltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociated
withtheusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyarenearthe
humidifier(image1).
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunction,afterthe
appliancehasbeendropped(3)ordamagedinany
otherway.
• Repairsofelectricalappliancesareonlytobemadeby
qualifiedserviceengineers(4).Improperrepairwork
cancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).
• Do not place the appliance directly on the flooror
nexttoaheatingvent(6).
• Ifthemistcomesincontactwiththefloorpriorto
evaporating,thefloorsurfacecanbecomedamaged.
Wedonotacceptanyliabilityfordamagesinthecase
ofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).
• Alwaysunplugwhennotinuse.
• Onlyoperatethehumidifierwhenitiscompletely
assembled.
• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/
dismantlingofindividualpartsandbeforemovingthe
appliance.
• Donottouchthewaterinthebaseduringoperation
becauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonot
coverwiththrowrugs.Arrangecordsothatitwillnot
betrippedover.
• Neverpulltheplugfromtheoutletbythecableorwith
wethands.
• Donotusetheappliancewherecombustiblegasesor
vaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,
inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.
• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockor
damagetotheappliance.Donotblockairoutletsor
intakes.
• Donotpourwaterintothemistoutletoftheappliance.
• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugis
intendedtofitinapolarizedoutletonlyoneway.Ifthe
plugdoesnotfitfullyintheoutlet,reversetheplug.Ifit
stilldoesnotfit,contactaqualifiedelectrician.DONOT
attempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andthe
ACoutletmaycauseoverheatingandadistortion
oftheplug.Contactaqualifiedelectriciantoreplace
looseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Donotsubmergethemainbodyinwaterorother
liquids.
• Disconnectpowersupplybeforeservicing.
• Personswhoarenotfamiliarwiththeinstructions
foruse,aswellaschildrenandpersonsunderthe
influenceofmedication,alcohol,ordrugsarenot
permittedtooperatetheappliance,orareonly
permittedtooperateitundersupervision.
• Toprotecthealth safetyandproper humidifierfunction
useonlyclean,contamination-free,cold,freshtapwa-
terinyourhumidifier.Ifyourwatersourceiscontam-
inatedorifyouareuncertainofitssafetyusedistilled
water.Inaddition,itisadvisedtoclean and maintain
your humidifierinatimelymanneras instructed in
this manual.
• Theuseofwateradditives,suchasethereal/essential
oils,fragrances,eucalyptus,waterconditionersetc.,
damagesthetankmaterialandasaconsequence
thewholeunit.Anyuseofsuchadditiveswillvoidthe
manufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehigh
frequencyvibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
7
en
5
1
3
7
96
2
4
8
8
en
Foreword
CongratulationsonchoosingtheUltrasonicHumidifier
AOSU600/U650fromAIR-O-SWISS!
Didyouknowthatdryroomair:
• Causesthemembranesinyourrespiratorysystemto
dryout,andalsocauseschappedlipsandstinging
eyes?
• Encouragesinfectionsandillnessesofrespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,carpets
andplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?
• Detunesmusicalinstruments?
General information
Acomfortableatmosphereindoorsisreachedwitharela-
tivehumiditylevelbetween40and60%.Yourhumidifier
automaticallycontrolsthehumiditylevelaccordingtothe
desiredsetting.Iftheairistoodry,thehumidifierwillauto-
maticallyswitchon.Assoonasthedesiredhumiditylevel
isreached,itwillswitchoff.
Unpacking
• Carefullyremovethehumidifierfromthebox.Place
yourhandsunderneaththeproducttopullitoutofthe
box(10).
• Warning:Donottaketheunitoutoftheboxbypulling
uponthetankhandle-basemayfallandwillbe
damaged(11).
•Removetheplasticbagfromthehumidifier.
• Observetheinformationgivenontheratingplateabout
thevoltage.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotusethehumidifierallyearround.
10
11
9
en
Description of the appliance
Mistoutlet(rotating)
Evaporationchamber
Watertank
Demineralizationcartridge
Mainbody
Controlpanel
Watertankcap
PowerPlug
Membrane
Nebulizerspace
Brush
WaterLevelSensor
HydroStick
10
en
Setting up
Findingtheideallocationforyourunit:
• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureof
themistcandamagethefloorsurface(6)(seeSafety
Instructions).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyat
plants,furniture,orotherobjects(12).Keepdistanceof
atleast20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(13).Thegranuleshaveto
absorbwatertoreachmaximumperformance.Ifthe
cartridgeissoakedinthetank,makesuretoexchange
thewaterandemptythewaterfromthebasebefore
usingthehumidifier.
• Onaveragethedemineralizationcartridgeshouldbe
replacedevery2–3monthsdependingonyourwater
hardness.Someareasmayneedtoreplacethe
cartridgesooner,somemaylastlonger.Thecartridge
mustbeexchangedatthelatestafter6monthsorthe
unitdoesnotreachitsfullperformanceanymore.
 See«Replacementofthedemineralizationcartridge».
• Readtheinstructionsunder«FillingtheTank»for
addingwaterinthehumidifier(14and15).
• Placethewatertankontothebase.
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offdial(18and19).
• About10to15minutesafteritisswitchedonthe
devicewillreachitsfulloutputlevel.
• Makesurethatthecableisnotpinchedanywhere(9).
Donotoperatethehumidifierifthecableisdamaged
(2).
12
13
11
en
R
RENT DESIRED
16
17
15 18
19
14
Filling the tank
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Toprotecthealth safetyandproper humidi-
fierfunctionuseonlyclean,contamination-free,
cold,freshtapwaterinyourhumidifier.Ifyour
watersourceiscontaminatedorifyouareuncertainofits
safetyusedistilledwater.
Do not operate the humidifier when the water tank is
empty!Whenthewater reaches theminimumlevel,the
unitswitchesoffthenebulizerfunctionautomatically.The
emptyindicatorlightcomesonshowingtankisempty.
•Removethewatertankfromthebaseandunscrewthe
watertankcap(14).
• Makesurethatnoforeignobjectsareinthewatertank.
• Fillthetankwithclean,coldwaterfromthetap(15).
Closethecapofthewatertanksecurely,placethe
watertankontothebase(16).Thewaterisnow
runningfromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance
(17).
• Inserttheplugintothesocket(18)andswitchonthe
applianceusingtheon/offdial(19).Theempty
indicatorlightmaystayilluminatedforsomeseconds
untilthebaseisfilledwithwater.
Do not use additives
Water additives (ethereal/essential oils, fragrances,
eucalyptus, water conditioners, etc.) must not be used!
Evenasmallamountcancausecracksinthematerial.The
materialisn’tmadefortheuseofsuchadditives.Onedrop
isenoughtodamagethetankandasaconsequencethe
unit.Anyuseofsuchadditiveswillvoidthemanufacturer’s
warranty.
12
en
A) On/Off Dial and regulation of mist output
Turningtheright-handrotarydialclockwiseswitchesthe
appliance on and at the same time regulates the mist
outputfromlowtohigh.
B) Hygrostat (setting the humidity level)
The desired humidity level can be set by turning the
left-hand rotary dial clockwise. A relative humidity of
between40%and60%isrecommended.Youcanachieve
thislevelbyrotatingthedialuntilitisroughlyinthevertical
position.Themeasurementaccuracyis+/-5%.Assoonasthe
humidity exceeds the desired setting, the appliance
switchesoff.Theappliancedoesnotswitchoffifthedialis
turnedallthewaytotheright.Thisactivatesthecontinuous
operationfunction.
Operation AOS U600 C) Operation with pre-heating (warm mist)
ButtonCisusedforswitchingthepre-heatingonandoff
(symbol Dlightsup).Asaresult,thewaterispre-heated
toatemperatureof176°F(80°C)beforeenteringthe
nebulizerspace.Ittakesapprox.10to15minutesforthe
waterinthebasetowarmup.Themistnowleavesthe
humidifieratapleasanttemperatureof104°F(40°C).
Theadvantageofthisisthattheroomtemperaturedoes
notdropand,inaddition,itsignificantlyimprovesthewater
qualitymaintenance.
D) Pre-heating indicator (On/Off)
E) Empty indicator (red)
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewa-
tertankisempty.Theredemptyindicatorisilluminated
(symbolE).Pleasereadthechapter«Fillingthetank»for
moreinformation.TheredsymbolEmaystayilluminated
forsomesecondswitharefilledtankuntilthebaseisfilled
withwater.
A
C
B
D
E
13
en
Operation AOS U650
CURRENT
TIME
DESIRED
A
C
D
EF
M
L
H
G
I
K
B
J N
A) On/Off Button and Display Dimmer
BypressingbuttonAonce,youcanswitchtheuniton.By
pressingittwice,thedimmerisswitchedonwhichauto-
matically dims thedisplay brightness andsymbol N
comes on. When changing any settings the display will
illuminateforafewsecondsbefore returningtodimmer
mode.BypressingbuttonAathirdtime,theunitisswitched
off.Thisbuttonisalsousedtoresetthecleaningindicator
light(byholdingdown).
B) Hygrostat (setting the humidity level)
BypressingbuttonByoucansetthedesiredhumiditylevel
from30%to80%orCO(continuousoperation).Arelative
humiditybetween40and60%isrecommended.Theac-
curacyofmeasurementis+/-5%.Theunitwillswitchoff
whenthemoisturelevelexceedsthedesiredsetting.During
selectionthetargetvalueisdisplayed(symbol DESIRED) . 
Thedisplaywillautomaticallyshowthecurrentvalueafter
afewseconds(symbol CURRENT).
C) Timer
UsingbuttonC,theoperationtimecanbesetadjustable
between 1 and 8 hours or CO (continuous operation).
Symbol Gshowstheoperatingperiodthathasbeenset
(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywillautomat-
icallyshowthecurrenthumidityafterafewseconds.
D) Mist output (regulating mist output)
ByrepeatedlypressingbuttonDyoucancontrolthemist
output. Symbol Hshows whichofthethreelevels(low/
medium/high)youhaveselected.
E) Operation with pre-heating (warm mist)
ButtonEisusedforswitchingthepre-heatingonandoff
(symbol Ilightsup).Asaresult,thewaterispre-heated
toatemperatureof176°F(80°C)beforeenteringthe
nebulizerspace.Ittakesapprox.10to15minutesforthe
waterinthebasetowarmup.Themistnowleavesthe
humidifieratapleasanttemperatureof104°F(40°C).The
advantageofthisisthattheroomtemperaturedoesnot
dropand,inaddition,it significantly improvesthe water
qualitymaintenance.
F) Automatic mode and Sleep mode
Theautomaticandsleepmodescanbeactivatedbypress-
ingbuttonF.Bypressingthebuttononce,theautomatic
functionisswitchedon(symbol Jappearsonthedisplay),
maintaining the optimum humidity subject to the tem-
perature.Controltakesplacebymeansofoutputquantity
andpre-settargetvalue.Bypressingthebuttontwice,the
sleepfunctionisswitchedon(symbol Kappearsonthe
display),thetargethumidityis50–65%;theoperationtime
issetat6hours;theheatingisswitchedonandthedisplay
brightnessisautomaticallydimmed.Inaddition,theoutput
quantityisalsocontrolledsubjecttothedifferencebetween
thetargetvalueandtheactualvalue.
Thehygrostatandmistoutputsettingscannotbechanged
ineithermode.IfthebuttonsBorDarepressed,theunit
willnolongerbeinautoorsleepmode.
G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewater
tankisempty.Theemptyindicatorisilluminated(symbolL).
Pleasereadthechapter«Fillingthetank»formoreinforma-
tion.ThesymbolLmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicator
IfsymbolM«CLEAN»appearsonthedisplay,theappliance
shouldbecleanedasrecommendedbythemanufacturer.
This symbol comes on automatically every 2 weeks,
dependingonthelevelofuse.The display can be reset
by holding down button A until the light disappears.
N) Dimmer Indicator

DisplayDimmerOff

DisplayDimmerOn
ForinstructionsseebuttonA
14
en
R
RENT DESIRED
23
22
21
20
Cleaning/Maintenance
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Caution – risk of electric shock and
damage of the product!
• Switchofftheappliance(20)andunplugitfromthe
socketbeforecleaningit(21).
• Cleanthewatertankandthebaseregularly.Usewater
only,nodetergents(22).
• UseAIR-O-SWISSEZCalcustomcleaninganddescaling
agentonlytoremovedepositsfromthemembrane
regularly(23).ThereisasampleofEZCalincludedin
thepackagingofyourhumidifier.Instructionsforusing
areonthepacket.Onlyuse1packetfor32ozofwater.
Donotchangetheratio.DoNOTruntheunitwhen
usingEZCal.Thiscancausedamagetotheproduct
andvoidsthewarranty.Thoroughlyrinsethebasewith
tapwaterafterusingEZCalandmakesurenoEZCal
residuesremaininthebase.
EZCalfromAIR-O-SWISSistheonlyrecommen-
dedcleaninganddescalingsolution.DoNOTuse
anyothercleaningsolutionssinceitcandamage
theproduct.Anyuseofcleaningsolutionsapart
fromEZCalwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater
(24)!
• Thecleaningindicatorstillappearsonthedisplayafter
cleaning.ToresetitholddowntheON/OFFbuttonuntil
thecleanlightdisappears.
• Cleantheinnerpartswithasoftcloth.Donotuseany
solventsoraggressivecleaningagentstocleanthe
appliance(25).
ACID
25
24
15
en
• Onlyusethebrushtocleanthemembrane.Thisshould
bedoneonceaweek.Onlyusethesoft-bristleportion
ofthebrush(26).
• Changethewaterinthetankatleastonceaweekif
waterisstandingformorethanaweek.
• Toremovethemistoutlet(27):Twistthetabsonthe
mistoutlettoeithertherightortheleft.Alignthetabs
andarrowonthemistoutletwiththearrowsonthe
ringaroundthemistoutlet.Pulluponthemistoutlet
oncethearrowsarealigned.
Water quality maintenance
TheAIR-O-SWISSHydro Stick 7017keepsAIR-O-SWISS
humidifiersoperatingattheirhighestlevelbetweenrec-
ommendedcleanings*.Goodforoneyear,theHydroStick
ensuresthehumidifier’sfunctionalitywhileprovidingfresh
humidificationperformance.
Itstarts to work assoonas it comesintocontact with
water,eveniftheunitisturnedoff.TheHydroStickshould
bechanged everyyear. Lookat picture 28 fortheposi-
tionoftheHydroStickinthebasepartoftheunit.Donot
touchthewaterinthebaseduringoperation!Switchoffthe
unitfirst.Contactyourlocalretailerorcheckourwebsite
www.airoswiss.net for reorder information.The replace-
mentHydroStickcomeswithametallicclipwhichisnot
neededfortheplacementinthisproducttype.
*Refertothecleaninginstructionsinthismanual.
Lifecycle Indicator
Yourappliancecomeswithalifecycleindicatorforchanging
theHydroStick.Toremindyourselfof whenyouputthe
HydroStickintooperation,pleasecrossthecurrentmonth
onthestampandwritethecurrentyearonthelineprovid-
ed(29).
26
28
29
27
16
en
30
31
•Turntheplasticcupandcartridgeoverandshakeuntil
allgranulesareinthecartridge(37).
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(38)andretainforfutureuse(the
refillgranulesconsistsof3refillbags)(39).
•Closethecartridge(40).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(43).Thegranuleshaveto
absorbwatertoreachmaximumperformance.Ifthe
cartridgeissoakedinthetank,makesuretoexchange
thewaterandemptythewaterfromthebasebefore
usingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).
•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(45).
Placinggranulesinthecenterofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge
•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counter-clockwise(31).Important:doNOTdisposeof
thewatertankcap!
• Throwthewholecartridgeintothewaste(41).
•Unpackthenewcartridge(42).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(43).Thegranuleshaveto
absorbwatertoreachmaximumperformance.Ifthe
cartridgeissoakedinthetank,makesuretoexchange
thewaterandemptythewaterfromthebasebefore
usingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).Close
tankcapwellandplacethetankonthemainbody
(45).
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
The water tank is equipped with a demineralization cart-
ridge.Thiscartridgehastobereplacedevery2–3months.
Ifthewaterisveryhard,itmaybenecessarytoreplacethe
cartridgeearlier.Whitedustaroundthedeviceisasuresign
thatthecartridgeneedsreplacing.Ifwhiteresiduestillforms
aroundthedeviceafteranewcartridgehasbeeninserted,
pleasemakesurethatthewateryouareusingisuntreated.
Ifthewaterflows
throughadecalcificationsystem–suchas
anionexchanger–(sodiumisaddedtoremovecalcium)in
thebuildingbeforeitisusedinthehumidifier,saltcanpre-
cipitateaswhitedustaroundthedevice.Thedemineralization
cartridgeorthe granules must beexchangedat the latest
after6monthsortheunitdoesnotreachitsfullperformance
anymore.
Option A: replace the granules
•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counter-clockwise(31).Important:doNOTdisposeof
thewatertankcap!
•Openthecartridge(32).
•Throwthecontentintothewaste(Attention!Disposed
granulescanmakethefloorslippery!)(33).
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(34).
•Pourthecontentsofonerefillgranulesbagintothe
plasticcupthatisincludedwiththerefillgranules
packaging(35).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(36).
32 33
17
en
45
44
34 35
36
37
38
39
41
43
40
42
18
en
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Legal notice
ThehumidifieriscUL-listed.
Subjecttotechnicalchange.Theinstructionsforuseare
protectedbycopyright©PLASTONAG.
Accessories
Contact your local retailer or check our website
www.airoswiss.netforreorderinformation.
Customer Service
CustomerService(USA)1-800-336-0326
www.airoswiss.net
Technical data
Electricalvoltage 120V/60Hz
Powerconsumptionupto 40W/(125W*)
Humidityoutputupto 3.5gallons/24h*
Suitableforroomsupto 650sqft/60m
2
Dimensions(LxWxH) 11x9.5x14in
28x24x35.5cm
Weight(empty) 8.8lbs/4kg
Accessories AOS7531Demineralizationcartridge
AOS7017HydroStick
*whenusedwithpre-heatingto176°F(80°C)
Troubleshooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal
Demineralizationcartridgeexhausted Replacecartridgeorgranules
Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow
withgranules themaway
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min.
thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush
Unitrunningintermittently Replacedemineralizationcartridgeorgranules
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste
19
en
General Humidifier Questions
Q.Why isn’t there enough moisture in my room?
A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropif
moistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the
unit is running?
A. a) Byleavingthedooropen,thisallowsmoistureto
leavetheroomandgointootherareasofthehouse.
Ifyouwouldlikethemoisturetostaywithinone
specificroomyoushouldconsiderclosingthedoor
whiletheunitisrunning.
A. b) Wood,leather,carpet,curtains,andothertypesof
fabricsoakupalotofmoisture,thusnotleaving
enoughmoisturefortheair.Ifthewindowisleft
open,thenthisallowsmoisturetoescapetheroom.
Anotherfactorisalotoftimestheunitisplacednext
toaheatingdevice.Theideaisthattheairblowing
intotheroomwillquicklyplacemoisturearoundthe
room.Unfortunately,thisconceptdoesnotwork
becausethehotaircomingoutofaventwillsoak
upmostofthemoisture,andnoneoftheairwithin
theroomwillreceiveany.
Q.How much moisture do I need in my room?
A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much
humidity?
A. Dryaircancausedryskin,staticelectricity,outoftune
musicalinstruments,increasedlevelsofdust(dryair
causesdusttorise),damagetowoodenobjects
(dryoutandeventuallycracksappear),discomfort,
sickness,anddriesoutnasalmembranes.
Over-humidifyingtheaircancausemoldandwallpaper
topeel.
Q.Why do I need a humidifier when I can just open
my window?
A. Themoisturelevelwithintheoutsideairisnothigh
enoughtohumidifyaroom.Thecoldertheairtheless
moistureitiscapabletohold,andthemoretheairis
heatedupthepercentageofrelativehumidityislower.
Relativehumiditymeanstheamountofwatervaporin
theair,comparedtotheamounttheaircouldholdifit
wastotallysaturated.Thedifferenceishigherbetween
outsideandinsidetemperatures;morehumidification
isneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?
A. Theunitshouldbefree-standingandnotclosetoa
wall,window,door,orthermalbridgesothatairmay
circulatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization
cartridge cap?
A. Thosedirectionsarethereincaseyoudecidetouse
therefilloptiontoreplacethegranules;thepurposeis
forhowtoopenandclosethecap.Ifyoudidopenthe
capbeforeplacingitinthewatertank,youwillmost
likelynoticethattherearegranulesinthewatertank
andthebaseoftheunit.Immediatelyturnofftheunit,
andemptythewateroutofthebaseandthewater
tank.Beginremovingallgranulesfrombaseandwater
tank.Usebrushtocleanaroundmembrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q.I just replaced my cartridge, and the contents and
water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreven
thegranules,arereplaced.Thisdoesnotoccurwithall
replacementcartridgesorgranules,andisareactionof
watercontentandtheUltrasonicvibrations.Thisisnot
anindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far
may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybe
filledallthewaytothetop.
Q.What is the purpose of the demineralization
cartridge (DMC)?
A.TheDMCremovesmineralsfromthewatertoprevent
whitedust.Thecontentsofthecartridgeneedtobe
soakedfor24hrspriortofirstusingtheunitsothatthey
mayfullyexpandandremovemineralsfromthewater.
ThecontentsoftheDMChavealifeof2–3months.
Thecartridgemayneedtobereplacedmoreoften
dependingonwaterhardnessandhowoftentheunit
isused.AnindicationofwhentheDMCneedstobe
changedcanbewhitedustorreducedamountofmist
output.
Q.Is it ok to use distilled water with the unit?
A. Forbestresultswithyourultrasonichumidifieruse
distilledorreverse-osmosiswaterandremovethe
demineralizationcartridge.
Q.I just replaced the contents of the cartridge and
now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddle
ofthecartridge.Placinggranulesinthemiddleofthe
DMCallowsthemtoescapeintheunit.Immediately
turnofftheunit,andemptythewateroutofthebase
andthewatertank.Beginremovingallgranules
frombaseandwatertank.Usebrushtocleanaround
membrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidity
intotheair.Becauseofthis,thecarpetingorwoodfloor
surroundingtheunitmaybecomedamp.Iftheunitis
20
en
placedatleast3feetoffthefloor,themistwillhavethe
opportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.
A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donot
pourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unit
A.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess.
Solve the problem:
•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoaked
inthewatertank,thewaterinthetankandthebase
needstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter1-2
monthswhenyouuseveryhardwater(forsofterwater
after2-3months).Nomatterhowhardyourwater
is,exchangethecartridgeattheverylatestafter6
months.
•Don’tusewaterfromapre-installedwatersoftener,
orsodiuminsteadofcalciumwillbeemittedfromthe
unit.Usedistilledwaterinsteadandremovethedemi-
neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterand
removethedemineralizationcartridge.
•UseReverse-Osmosiswater(R-Owater)insteadof
distilledwaterandremovethedemineralizationcart-
ridge.
•Cleaning light is illuminated (digital models)
Switchofftheunitandunplugit.Emptythewaterin
thebase.Rinsethebasewithhot/cleanwater.Donot
submergethebase!Visuallyinspectthebasefordirtor
mineralbuildup.Ifsoftwaterisuseddecalcifyingthe
unitevery4weekswithEZCalissuggested.Ifhard
waterisusedtheunitshouldbedecalcifiedevery
2weeks.Donotforgettoresetthecleanlightafter
resettingtheunit.
Q.Reset cleaning light (digital models)
A. Thecleaninglightdoesnotautomaticallyreset.Hold
downthepowerbutton(buttonAininstructionmanual)
untilthelightstopsflashing.Thelightautomatically
comesonapprox.after14daysofpluggingintheunit.
Q.The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmost
areoffby+/-5%.Plusthehumiditylevelisnotthe
sameinthewholeroom.Theaircirculationisdifferent
ineverycorneroftheroom.Theunitshouldnotbe
placednearaheatingventoraradiatorastheheatwill
absorballofthemoisture.
Q.Humidity level is not changing or does not reach
the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceper
day,theunitisworkingproperlyandtheclimatic
conditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:
•aircirculationisveryhigh(airisfullyexchanged
severaltimesperday–thehumidifierneedstostarts
itsworkfromscratch)
•insulationofhome(seeaircirculation)
•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–high-risebuil-
dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitis
verycoldoutsidedon’topenthewindowmorethan
2timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinside
temperature–thecoldertheairthelessmoistureit
iscapabletoholdandthemoretheairisheatedup
theloweristhepercentageofrelativehumidity(=the
amountofwatervaporintheair,comparedtothe
amounttheaircouldholdifitwastotallysaturated)
•positionoftheunit-ifitisplacedclosetoadoor,
windoworairvent.Thisincreasestheaircirculation.
Q.Tank is leaking
A. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunder
thewarranty.Pleasecontacttheretailertheunitwas
purchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mist
A. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbe
playedwith.
Q.No mist / unit is not working / empty indicator
keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthrough
thedemineralizationcartridge(attachedtothewater
tankcap).Ifthewatertankisfullbutthereisonlylittle
waterinthebaseitindicatesthatthewaterisnow
flowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutof
theunit.
•Iftheunitisnotworkingandtheemptylightisnot
flashingyoumighthavesetthedesiredhumiditytoo
lowandthecurrenthumiditylevelintheroomis
higher.Thatiswhytheunitswitchesoffautomatically.
•Iftheemptyindicatorkeepsflashingandthetankis
full,thewaterisnotflowingthroughthecartridge.
Exchangethecartridgeorthegranulesinthecartridge
after2-3months,inareaswithhardwaterexchange
thecartridgeafter1-2months.However,thedemi-
neralizationcartridgeandorthegranulesmustbe
exchangedatthelatestafter6monthsortheunitdoes
notreachitsfullperformanceanymore
•Ifthegranulesarenew,seethefollowinginstructions:
•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwater
tofilterthroughthecartridgeandintothebase.Next,
pleaseremove2tablespoonsofgranulesfromthe
cartridge,andthrowthemaway.Whentherearetoo
manygranulesinthecartridgeitdoesnotallowwater
toflowfromthetanktothebase.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Air-O-Swiss U600 User manual

Category
Humidifiers
Type
User manual
This manual is also suitable for

Air-O-Swiss U600 helps you to maintain a pleasant and healthy room climate by increasing the humidity level in the air to counteract dry air, which can cause a range of health issues including dry and irritated skin and respiratory issues. The device is equipped with the latest technology and features to deliver effective and efficient humidification for rooms up to 25 m2 (270 ft2). Air-O-Swiss U600 features include:

  • Adjustable mist output: Allows you to customize the humidity level to your desired comfort level.
  • Automatic humidity control: Maintains the desired humidity level by automatically adjusting the mist output.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI