— 3 —
MODEL KA7EVH VENTLESS HOOD
OPERATION
CONTROLS
Airow Reset
Fan On
Fan Auto
Power Light
(GREEN)
Error Light: Airow
(YELLOW)
Error Light:
Temperature High Limit
(RED)
Hood Switch Plate
Fan ON switch position
Turns the hood fan on. The hood fan runs continuously.
Fan AUTO switch position
The hood fan turns on automatically when the oven on/off rocker switch is turned on.
The hood fan turns off automatically 30 minutes after the oven on/off rocker switch is turned off. The auto
switch position is recommended for energy savings.
Power Light (GREEN)
This (GREEN) light indicates that there is power to the hood.
Error light: Airow (YELLOW)
This (YELLOW) light indicates that there is a low or high airow condition. Because the hood is not operating
properly, the interlock control turns the oven heaters off.
The oven stops cooking. The oven display will indicate cooking but the heaters are off.
If the airow error cannot be immediately corrected, manually abort the cook cycle.
Incorrect airows are a result of clogged or missing lters, loose access panels, intake or discharge blockage. This
condition must be corrected before normal operation of the oven and hood can resume. (See Troubleshooting.)
Airow Reset Button
Push the airow reset button after correcting an airow error condition (clogged or missing lters, loose
access panels, intake or discharge blockage). Once the reset button has been pushed, the internal airow
switch will verify that the airow is correct and the (YELLOW) light will go out.
Error light: High Temp Light (RED)
If this light turns on, call Hobart Service.
This (RED) light indicates that the hood has overheated. Because the hood is not operating properly,
the interlock control turns the oven heaters off.
The oven stops cooking. The oven display will indicate cooking but the heaters are off. Manually abort the
cook cycle. Cooking cannot be resumed until the problem is corrected by Hobart Service.