Panasonic FV-11VH2 User manual

Type
User manual
I
II
III
Maintenance (Cleaning)
I
Maintenance (Replacement of lamp)
II
Model No.
FV-11VH2
FV-11VHL2
Ventilating Fan
Thank you very much for having purchased our Ventilating Fan.
FV-11VH2 FV-11VHL2
back cover
back cover
The Panasonic ceiling mount ventilating fans uses a sirocco fan driven by a capacitor motor. The motor is
designed to have an extended service life with reduced energy consumption. It also incorporates a
thermal cut-off for safety. The grille covering the main body is a spring-loaded, quick-release type. A
damper for preventing counterflow is provided. The blower uses a high-capacity sirocco fan developed to
reduce the noise level.
The heater for this unit is a 1400 W sheathed heater. A thermostat and thermal cut-off switch have been
added for safety in case of an abnormal temperature rise in the heater.
The lighting unit is an energy-saving, lighting device which uses two 18 W fluorescent lamps and produces
almost the same illumination as a standard 100 W incandescent lamp (FV-11VHL2).
UNPACKING
SUPPLIED ACCESSORIES
DESCRIPTION
Unpack and carefully remove unit from carton.
Refer to the Supplied Accessories list to verify that all parts are present.
FOR MODEL FV-11VH2
FOR MODEL FV-11VH2
POURLE MODELE FV-11VHL2
POURLE MODELE FV-11VHL2
Ventilating unit
DIMENSIONS
2 1/8 (54.8)
14 (357.8)
18 1/8 (460)
2 1/2 (62)
11 7/8 (301)
13 1/4 (337.8)
7 5/8 (195)
5 (128.7)
11 1/4 (285.5)
18 1/8 (460)
7 3/4 (196)
1 (25)
16 (407)
19 1/2 (497)
19 1/2 (497)
16 (407)
11 1/4 (285.5)
5 (128.7)
7 3/4 (196)
7 5/8 (195)
2 1/2 (62)
11 7/8 (301)
1540
3. This product must be properly grounded.
Noise
Vent
(sone)
0.6
0.7
Only for FV-11VHL2.
AC 120V, 60Hz.
SPECIFICATIONS
GENERAL SAFETY INFORMATION
650
720
29.5
Exhaust &
Circulation
10. This product (FV-11VHL2) has a fluorescent lamp that contains mercury. Disposal may be regulated in your
community due to environmental considerations. For disposal or recycling information, please contact your
local authorities or the Electronics Industries Alliance:http://www.eiae.org
Vent (0.1" WG)
(cfm)
8. Make sure that all duct work is properly vented.
9. DO NOT INSTALL THIS UNIT OVER A BATHTUB OR SHOWER ENCLOSURE.
15.6
(7.1)
17.8
(8.1)
GENERAL SAFETY INFORMATION CONTINUED
Circulating fan unit
Red
White
Black
Motor(C)
White
Thermal cut-off
oo
(230 F (110C))
Heater
(1400W)
Thermostat
oo
(140 F (60C))
Fuse
(20A)
Ventilating fan unit
Red
White
Black
Motor(V)
Capacitor
Black
White
White
Black
Junction box
Green
Earth ground
Power Supply
AC120V 60Hz
Switch(not
included)
Switch(not
included)
WIRING DIAGRAM
WARNING:
To reduce the risk of fire, electric shock or injury to persons, observe the following:
Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact
the manufacturer.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction. Neither unauthorized modification, repair nor
disassembly is allowed.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel
buming equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the
risk of fire or electric shock, do not use this unit with any solid-state control device.
Never place a switch where it can be reached from a tub or shower.
Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for
installation in Canada only.)
Use only on 20 ampere branch circuit.
A.
B.
C.
D.
E.
F.
G.
I.
J.
H.
Before servicing or cleaning unit, switch power off at service panel and lock panel cabinet to prevent
power from being switched on accidentally. If the panel cabinet cannot be locked, securely fasten a
clearly visible warning label to the service panel.
PCB
ON
OFF
ON
OFF
Black
Power Supply
AC120V 60Hz
Circulating fan unit
Motor(C)
Earth ground
Junction box
Motor(V)
Ventilating fan unit
ON
OFF
ON
OFF
OFF
ON
ON
OFF
PCB
Red
White
Black
White
Black
Fuse
(20A)
Thermal cut-off
oo
(230 F (110C))
Heater
(1400W)
Thermostat
oo
(140 F (60 C))
Lighting unit
Fluorescent lamp
Electronic
ballast
White
Black
Fuse
(3.15A)
Red
White
Black
Capacitor
Night lamp
Black
White
Black
White
Black
Black
White
Green
Switch(not
included)
Power Supply
AC120V 60Hz
Power Supply
AC120V 60Hz
Power Supply
AC120V 60Hz
Switch(not
included)
Switch(not
included)
Fig.2-2
Fig.2-1
(Fig.3)
Fig.2-3
Illustrations in this manual common use the image of
FV-11VHL2, and mark for FV-11VHL2 only, others are
same for FV-11VH2.
INSTALLATION (JOIST MOUNTING- )
Fig.3
Fan body
Suspension
bracket
Suspension
bracket
Suspension
bracket
Suspension
bracket
Fan body
Suspension
bracket
Suspension
bracket
Suspension
bracket
Fan body
Fan body
Joist
4 Long screws (ST4.2X20)
2 Screw (ST4.2X8)
Suspension bracket
Suspension bracket
2. Insert the suspension bracket into the fan body.
(Select the suspension bracket as shown below.)
Fig.1
Tape
Fan body
Warning label
Fig.4-2
Joist
2 Long screws
(ST4.2X20)
Screw
(ST4.2X12)
Joists
16 inches and 19.2 inches
horizontal joists
Fig.4-1
16 inches and 19.2 inches
horizontal joists refer to Fig.4-1, 19.2 inches vertical
joists and 24 inches refer to Fig.4-2.
Joist
2 Long screws
(ST4.2X20)
Screw
(ST4.2X12)
1. Before installation, remove warning lable and the tape
that is securing the adapter and the damper. (Fig.1)
6. Refer to wiring diagram (Page.5)
Follow all the local electrical safety codes. As well as
the National Electrical Code (NEC).
Using UL approved wire nuts, connect house power
wires to ventilating fan wires (Fig.6):
Black to black; white to white; green to green.
Make sure all connections are fastened firmly after
wiring is finished.
Replace the junction box plate, and then replace
lighting cord to hook. (Fig.5)
Fig.10
Fig.9
Fig.8
Fig.5
8. Finish ceiling work. Ceiling hole should be aligned
with the edge of the flange. (Fig.8)
(Fig.10)
INSTALLATION (JOIST MOUNTING- ) CONTINUED
7. Install the circular duct (4 inches) to the adaptor and
secure it with duct tape or clamps. (Fig.7)
Fig.7
Circular duct
Conduit
Correct
Incorrect
9. Install the fluorescent lamps and then install the
night lamp. (Fig.8)
Fluorescent lamp
12 5
/8 (319)
17 3/8 (441)
Screw driver
Fig.6
Junction box plate
Black to black
White to white
White to white
Black to black
Black to black
White to white
Black to black
Junction box
Green to green
Wire nut
Fan body
Joist
4 Long screws (ST4.2X20)
Slot
Mounting spring
Grille
Switch
labels
Switch
labels
For Model FV-11VHL2 For Model FV-11VH2
Note:Do not mount grille and springs conversely. If
the grille is mounted in the opposite direction,
the grille can not be fitted to the ceiling, so
then reverse the grille position and try to
mount again.
10. Insert mounting springs into slots as shown and
mount grille to fan body. (Fig.9)
Duct tape
or clamps
Screw
Junction box
plate
5. Remove the lighting cord out from hook (FV-11VHL2),
then remove junction box plate and secure conduit or
stress relief to wiring box knock-out hole.(Fig.5)
Lighting cord
Hook
Conduit
Night lamp
Fig.11
Fig.12
Fig.12
Fig.11
Illustrations in this manual common use the image of
FV-11VHL2.
INSTALLATION (BETWEEN JOIST MOUNTING)
Suspension
bracket
Suspension
bracket
Suspension
bracket
Fan body
Fan body
Joists
Adaptor
Junction box
Suspension bracket
C
B
(Select the suspension bracket according to spacing A
as shown below.)
Spacing A on center joists
16 inches
19.2 inches horizontal joists
19.2 inches vertical joists
B
13 1/4 ~ 15 1/2 (336~394)
14 3/4 ~ 16 3/4 (374~425)
16 1/2 ~ 18 3/4 (419~476)
1. Before installation, remove warning lable and the tape
that is securing the adapter and the damper. (Fig.1)
Keep the distance C (1/2 inch, 12.7 mm) for the
thickness of ceiling board.
Fig.15
Fig.16
(Fig.15, Fig.16)
INSTALLATION (WOODEN HEADER INSTALLATION)
11 3/8 (290)
19 7/8 (505)
Adaptor
Fan body
Ceiling joist
Ceiling joist
Header
Adaptor
Circular
duct
Long screw (ST4.2X20)
4. Follow step 5 of installation (page 7) to complete the
installation work.
1. Before installation, remove warning lable and the tape
that is securing the adapter and the damper. (Fig.1)
INSTALLATION (BETWEEN JOIST MOUNTING) CONTINUED
Fig.13, Fig.14
Fig.14
6. Follow step 5 of installation (page 7) to complete the
installation work.
Fig.13
Fig.14
Joist
2 Long screws
(ST4.2X20)
4 Long screws
(ST4.2X20)
Joist
2-Screw
(ST4.2X12)
Fig.17
Fig.18
Fig.19
Fig.20
Fig.17
Fig.18
Fig.19
Fig.20
oo
60 C(140 F).
MAINTENANCE (CLEANING)
2
1
Slot
Mounting spring
Grille
Gloves
Vacuum cleaner
1
5. Replace grille.
Do not allow any water to get into the motor.
Fig.22
3. Change the fluorescent lamps (FDS18E35/4, 18 W)
(Fig.22) or the 4 W night lamp(Fig.21), replace the
grille.
(Fig.17 of page 10)
Fig.21
MAINTENANCE (REPLACEMENT OF LAMP)
2. Remove the 4 W night lamp.(Fig.21)
Fluorescent lamp
Fluorescent lamp
4. Be sure to remove the night lamp before removing fluorescent lamps.
Night lamp
Fig.23
Fig.23
X0308-0 11VH24200
PRACTICAL GUIDE TO INSTALLATION
Foil tape tightly covers all metal
duct joints (glue PVC joints).
Insulation
Short piece of flexible duct
helps alignment and absorbs
sound. Use clamps plus tape
at all flex joints.
In attic installation,
caulk box to drywall.
2-3 ft straight run before elbow.
Caulk termination to duct.
Dryer-hood type vent with
backdraft flap (s).
Properly insulate the area around the fan to
PANASONIC CONSUMER ELECTRONICS COMPANY
Division de Panasonic Corporation of North America,
PANASONIC CANADA INC.
5770 Ambler Drive, Mississauga, ON L4W 2T3
www.panasonic.com
www.panasonic.ca
One Panasonic Way, Secaucus, NJ 07094
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Panasonic FV-11VH2 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI