Tyan B7018Y290D2 is a highly optimized rack mount barebone system, designed to support up to (2) Intel Xeon 5500 Series processors and up to 96GB RDIMM or 48GB UDIMM DDR3-800/1066/1333 memory per node. Utilizing advanced technology from Intel®, the B7018Y290D2 system provides scalable 32/64-bit computing, high bandwidth memory design, and lightning-fast PCI-E bus capabilities. The B7018Y290D2 not only manages today’s IT environments, but also lays a strong foundation for future growth and expansion as your business needs increase.

Tyan B7018Y290D2 is a highly optimized rack mount barebone system, designed to support up to (2) Intel Xeon 5500 Series processors and up to 96GB RDIMM or 48GB UDIMM DDR3-800/1066/1333 memory per node. Utilizing advanced technology from Intel®, the B7018Y290D2 system provides scalable 32/64-bit computing, high bandwidth memory design, and lightning-fast PCI-E bus capabilities. The B7018Y290D2 not only manages today’s IT environments, but also lays a strong foundation for future growth and expansion as your business needs increase.

http://www.tyan.com
B7018Y290D2
Service Engineer’s Manual
2
http://www.tyan.com
3
http://www.tyan.com
PREFACE
Copyright
This publication, including all photographs, illustrations, and software, is
protected under international copyright laws, with all rights reserved.
Neither this manual, nor any material contained herein, may be reproduced
without written consent of manufacturer.
Copyright 2010 MiTAC International Corporation. All rights reserved. TYAN
®
is
a registered trademark of MiTAC International Corporation.
Version 1.1
Disclaimer
Information contained in this document is furnished by MiTAC International
Corporation and has been reviewed for accuracy and reliability prior to printing.
MiTAC assumes no liability whatsoever, and disclaims any express or implied
warranty, relating to sale and/or use of TYAN
®
products including liability or
warranties relating to fitness for a particular purpose or merchantability. MiTAC
retains the right to make changes to produce descriptions and/or specifications
at any time, without notice. In no event will MiTAC be held liable for any direct
or indirect, incidental or consequential damage, loss of use, loss of data or
other malady resulting from errors or inaccuracies of information contained in
this document.
Trademark Recognition
All registered and unregistered trademarks and company names contained in
this manual are property of their respective owners including, but not limited to
the following.
TYAN
®
is a trademark of MiTAC International Corporation.
Intel
®
is a trademark of Intel
®
Corporation.
AMI
®
, AMIBIOS
®
and combinations thereof are trademarks of AMI
Technologies.
Microsoft
®
, Windows
®
are trademarks of Microsoft Corporation.
IBM
®
, PC
®
, AT
®
and PS/2
®
are trademarks of IBM Corporation.
Winbond
®
is a trademark of Winbond Electronics Corporation.
4
http://www.tyan.com
Federal Communication Commission (FCC)
Notice for the USA
Compliance Information Statement (Declaration of
Conformity Procedure) DoC FCC Part 15: This
device complies with part 15 of the FCC Rules
Operation is subject to the following conditions:
1) This device may not cause harmful interference;
2) This device must accept any interference received including interference
that may cause undesired operation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try one or more of the
following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and the receiver.
– Plug the equipment into an outlet on a circuit different from that of the receiver.
Consult the dealer on an experienced radio/television technician for help.
Notice for Canada
This apparatus complies with the Class A limits for radio interference as
specified in the Canadian Department of Communications Radio Interference
Regulations. (Cet appareil est conforme aux norms de Classe A d’interference
radio tel que specifie par le Ministere Canadien des Communications dans les
reglements d’ineteference radio.)
Notice for Europe (CE Mark)
This product is in conformity with the Council
Directive 89/336/EEC, 92/31/EEC (EMC).
CAUTION: Lithium battery included with this board. Do not puncture, mutilate, or
dispose of battery in fire. There will be danger of explosion if battery is incorrectly
replaced. Replace only with the same or equivalent type recommended by
manufacturer. Dispose of used battery according to manufacturer instructions
and in accordance with your local regulations.
5
http://www.tyan.com
About this Manual
This manual provides you with instructions on installing your TYAN
B7018Y290D2. This Manual is intended for experienced users and
integrators with hardware knowledge of personal computers.
This manual consists of the following parts:
Chapter1:
Provides an introduction to the TYAN B7018Y290D2
barebones, standard parts list, describes the external
components, gives a table of key components, and
provides block diagram of the system.
Chapter2:
Covers procedures on installing the CPU, memory
modules and hard drives.
Chapter3:
Covers removal and replacement procedures for
pre-installed components.
Appendix:
List the cable connection and FRU part tables for
reference of system setup, and technical support
in
case a problem arises with your system.
6
http://www.tyan.com
SAFETY INFORMATION
Before installing and using TYAN B7018Y290D2, take note of the following
precautions:
·Read all instructions carefully.
·Do not place the unit on an unstable surface, cart, or stand.
·Do not block the slots and opening on the unit, which are provided for
ventilation.
·Only use the power source indicated on the marking label. If you are not
sure, contact the power company.
·The unit uses a three-wire ground cable, which is equipped with a third
pin to ground the unit and prevent electric shock. Do not defeat the
purpose of this pin. If you outlet does not support this kind of plug,
contact your electrician to replace your obsolete outlet.
·Do not place anything on the power cord. Place the power cord where it
will not be in the way of foot traffic.
·Follow all warnings and cautions in this manual and on the unit case.
·Do not push objects in the ventilation slots as they may touch high
voltage components and result in shock and damage to the
components.
· When replacing parts, ensure that you use parts specified by the
manufacturer.
·When service or repairs have been done, perform routine safety checks
to verify that the system is operating correctly.
·Avoid using the system near water, in direct sunlight, or near a heating
device.
·Cover the unit when not in use.
7
http://www.tyan.com
Table of Contents
Chapter 1: Overview.........................................................................9
1.1 About the TYAN B7018Y290D2 ............................................... 9
1.2 Features.................................................................................. 10
1.3 Product Model......................................................................... 15
1.4 Standard Parts List ................................................................. 16
1.4.1 Box Contents Per Node................................................... 16
1.4.2 Accessories ..................................................................... 18
1.5 About the Product................................................................... 20
1.5.1 System Front View (Per Node)........................................ 20
1.5.2 System Rear View (Per Node) ........................................ 22
1.5.3 Internal View (Per Node) ................................................. 23
Chapter 2: Setting Up.....................................................................25
2.0.1 Before you Begin ............................................................. 25
2.0.2 Work Area........................................................................ 25
2.0.3 Tools ................................................................................ 25
2.0.4 Precautions...................................................................... 26
2.1 Installing Motherboard Components....................................... 27
2.1.1 Installing the DVD-ROM Drive (Optional)........................ 27
2.1.2 Installing the CPU and Heatsink...................................... 31
2.1.3 Installing the Memory....................................................... 35
2.2 Rack Mounting........................................................................ 38
2.2.1 Installing the Server in a Rack......................................... 38
2.2.2 Installing the inner Rails to the Chassis........................... 39
2.2.3 Installing the Outer Rails to the Rack .............................. 40
2.2.4 Rack mounting the Server ............................................... 41
Chapter 3: Replacing Pre-Installed Components ........................ 47
3.1 Introduction ............................................................................. 47
3.2 Disassembly Flowchart........................................................... 47
3.3 Replacing Motherboard Components..................................... 49
3.3.1 Replacing Expansion Card .............................................. 49
3.3.2 Disconnecting All Motherboard Cables ........................... 52
3.3.3 Removing the Motherboard ............................................. 54
3.4 Replacing the Power Distribution Board ............................... 55
3.5 Replacing the Front Panel Board.......................................... 57
3.5.1 Front Panel Board Features ............................................ 60
3.5.2 Front Panel Board Connector Pin Definition ................... 60
3.6 Replacing the System Fan.................................................... 61
3.7 Replacing the M7018-BP2 HDD Backplane Board .............. 63
8
http://www.tyan.com
3.7.1 M7018-BP2 HDD Backplane Board Features ................. 65
3.7.2 M7018-BP2 Connector Pin Definitions............................ 66
3.8 Replacing the Power Supply................................................. 68
Appendix I: Cable Connection Tables .......................................... 69
Appendix II: FRU Parts Table ........................................................ 73
Appendix III: Technical Support....................................................75
9
http://www.tyan.com
Chapter 1: Overview
1.1 About the TYAN B7018Y290D2
Congratulations on the purchase of the TYAN B7018Y290D2, a highly optimized
rack mount barebone system. The B7018Y290D2 is designed to support up to (2)
Intel
®
Xeon 5500 Series processors and up to 96GB RDIMM or 48GB UDIMM
DDR3-800/1066/1333 memory per node. Utilizing advanced technology from
Intel
®
, the B7018Y290D2 system provides scalable 32/64-bit computing, high
bandwidth memory design, and lightning-fast PCI-E bus capabilities. The
B7018Y290D2 not only manages today’s IT environments, but also flexibility for
future application usage.
TYAN
®
also offers the B7018Y290D2 in a version that can support up to sixteen
hot-swap hard drives (eight per node). The B7018Y290D2 uses latest chassis
designs which features a solid mechanical enclosure and robust features. All of
this provides the B7018Y290D2 with the power and flexibility to meet the needs
of today’s server applications.
10
http://www.tyan.com
1.2 Features
TYAN YR290B7018 (B7018Y290D2-045W8HR)
Form Factor 2U Rackmount Frame w/ 2x 2U Blades
Chassis Model YR290
Dimension (D x W x
H)
28.74" x 17.32" x 3.44" (730 x 440 x 87.5mm)
Blade Dimension
(D x W x H)
28.74" x 8.46" x 3.32" (730 x 214.8 x 84.5mm)
Motherboard S7018GM3NR
Board Dimension 6.3"x16.4" (160x416.6mm), per blade
Gross Weight 27 kg
System
Feature Two nodes in one chassis
Buttons (1) RST / (1) PWR / (1) ID
LEDs (1) PWR / (1) BMC / (2) LAN / (1) HDD
Front Panel (per
blade)
I/O Ports (2) USB ports
Type / Q'ty 2.5" Hot-Swap / (8)
External Drive
Bay (per blade)
Supported HDD
Interface
SATA-II 3.0Gb/s / SAS 3.0Gb/s
FAN (3) 6cm fans
System Cooling
Configuration
(per blade)
Air Duct (1) Customized for the YR290 blade
Peripherals (per
blade)
Type of ODD / Q'ty Ultra-slim DVD-ROM (optional)
Type ERP1U cold-swap
Input Range Full-range AC(100-240V)
Frequency 47 - 63 Hertz
Output Watts 450 Watts
Efficiency PFC / 80-plus Silver
Redundancy 1+1
Power Supply
(per blade)
Serviceability Hot-swap
Supported CPU
Series
Intel Xeon Processor 5500 Series
Socket Type / Q'ty LGA1366 / (2)
Thermal Design
Power (TDP)
wattage
Max up to 95W
System Bus
Up to 4.8/ 5.86/ 6.4GT/s with Intel QuickPath
Interconnect (QPI) support
Processor (per
blade)
CPU list Please refer to our Web site for the latest update.
Chipset (per
blade)
MCH / ICH Intel 5500 / ICH10R
11
http://www.tyan.com
Supported DIMM
Qty
(6)+(6) DIMM slots
DIMM Type / Speed
DDR3 800/1066/1333* RDIMM/UDIMM / * limit 1
per channel for 1333MHz speed
Capacity Up to 96GB RDIMM / 48GB UDIMM
Memory channel 3 Channels per CPU
Memory (per
blade)
Memory voltage 1.5V
PCI-E (1) PCI-E Low-Profile Gen.2 x16 slot
Pre-install TYAN
Riser Card
M7018-R16-1F1YR1L, 2U PCI-E x16 riser card
(right)
Expansion Slots
(per blade)
Max. HBA
Dimension (H x L)
(1) 68.90mm x 167.65mm (HH/HL) / (1)
111.15mm x 312.00mm (FH/FL)
Port Q'ty Total (3) ports, (1) dedicated for IPMI
LAN (per blade)
Controller Intel 82576EB / Intel 82574L
Connector
(2) Mini-SAS connectors (totally support 8 ports),
from TYAN P3202 storage adapter card
Controller LSI 1068E
Speed 3.0 Gb/s
SAS
RAID RAID 0/1/10 standard
Connector (4) SATA
Controller Intel ICH10R
Speed 3.0 Gb/s
Storage (per
blade)
SATA
RAID RAID 0/1/10/5 (Intel Matrix RAID)
Connector type D-Sub 15-pin
Resolution 1600x1200@60Hz
Graphic (per
blade)
Chipset Aspeed AST2050
USB (5) ports (2 at front, 2 at rear, 1 Type A onboard)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O ports (per
blade)
RJ-45 Total (3) ports, (1) dedicated for IPMI
Chipset Winbond W83793G
Temperature
Monitors temperature for CPU & system
environment
LED
Fan fail LED indicator / Over temperature
warning indicator
System
Monitoring (per
blade)
Others
Chassis intrusion detection / Watchdog timer
support
Onboard Chipset Onboard Aspeed AST2050
AST2050 IPMI
Feature
IPMI 2.0 compliant baseboard management
controller (BMC) / USB 2.0 virtual hub / BIOS
update
Server
Management (per
blade)
AST2050 iKVM 24-bit high quality video compression / Dual
12
http://www.tyan.com
Feature 10/100 Mb/s MAC interfaces
Brand / ROM size AMI / 4MB
BIOS (per blade)
Feature
Multiple boot options / Plug and Play (PnP)
/PCI2.3 /WfM2.0 /SMBIOS2.3 /PXE boot / ACPI
2.0 power management /Power on mode after
power recovery / User-configurable H/W
monitoring / Auto-configurable of hard disk types
Operating
System
OS supported list Please refer to our Web site for the latest update.
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating
Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating
Environment
In/Non-operating
Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6
Complaint
Yes
Manual
(1) Quick Ref. Guide / (1) MB User's manual + (1)
BB User's manual
Installation CD (1) TYAN installation CD
Heatsink / Cooler (4) LGA1366 CPU heatsinks
Rail kit (1) sliding rail kit for YR290
Package
Contains
Cable Power Cord
(4) CCBL-0310, US type power cords / (4)
CCBL-0300, EU type power cords
TYAN YR290B7018 (B7018Y290D2-045V8H [BTO])
Form Factor 2U Rackmount Frame w/ 2x 2U Blades
Chassis Model YR290
Dimension (D x
W x H)
28.74" x 17.32" x 3.44" (730 x 440 x 87.5mm)
Blade
Dimension (D x
W x H)
28.74" x 8.46" x 3.32" (730 x 214.8 x 84.5mm)
Motherboard S7018GM3NR
Board
Dimension
6.3"x16.4" (160x416.6mm), per blade
Gross Weight 27 kg
System
Feature Two nodes in one chassis
Buttons (1) RST / (1) PWR / (1) ID
Front Panel
(per blade)
LEDs (1) PWR / (1) BMC / (2) LAN / (1) HDD
13
http://www.tyan.com
I/O Ports (2) USB ports
Type / Q'ty 2.5" Hot-Swap / (8)
External
Drive Bay
(per blade)
Supported HDD
Interface
SATA-II 3.0Gb/s
FAN (3) 6cm fans
System
Cooling
Configuratio
n (per blade)
Air Duct (1) Customized for the YR290 blade
Peripherals
(per blade)
Type of ODD /
Q'ty
Ultra-slim DVD-ROM (optional)
Type ERP1U cold-swap
Input Range Full-range AC(100-240V)
Frequency 47 - 63 Hertz
Output Watts 450 Watts
Efficiency PFC / 80-plus Silver
Redundancy 1+0
Power
Supply (per
blade)
Serviceability Hot-swap
Supported CPU
Series
Intel Xeon Processor 5500 Series
Socket Type /
Q'ty
LGA1366 / (2)
Thermal Design
Power (TDP)
wattage
Max up to 95W
System Bus
Up to 4.8/ 5.86/ 6.4GT/s with Intel QuickPath
Interconnect (QPI) support
Processor
(per blade)
CPU list Please refer to our Web site for the latest update.
Chipset (per
blade)
MCH / ICH Intel 5500 / ICH10R
Supported DIMM
Qty
(6)+(6) DIMM slots
DIMM Type /
Speed
DDR3 800/1066/1333* RDIMM/UDIMM / * limit 1 per
channel for 1333MHz speed
Capacity Up to 96GB RDIMM / 48GB UDIMM
Memory channel 3 Channels per CPU
Memory (per
blade)
Memory voltage 1.5V
PCI-E (1) PCI-E Low-Profile Gen.2 x16 slot
Pre-install TYAN
Riser Card
M7018-R16-2F1L, 2U PCI-E x16 riser card (right)
Expansion
Slots (per
blade)
Max. HBA
Dimension (H x
L)
(2) 111.15mm x 312.00mm (FH/FL) / (1) 68.90mm x
167.65mm (HH/HL)
LAN (per
Port Q'ty Total (3) ports, (1) dedicated for IPMI
14
http://www.tyan.com
blade) Controller Intel 82576EB / Intel 82574L
Connector (4) SATA
Controller Intel ICH10R
Speed 3.0 Gb/s
Storage (per
blade)
SATA
RAID RAID 0/1/10/5 (Intel Matrix RAID)
Connector type D-Sub 15-pin
Resolution 1600x1200@60Hz
Graphic (per
blade)
Chipset Aspeed AST2050
USB (5) ports (2 at front, 2 at rear, 1 Type A onboard)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O ports (per
blade)
RJ-45 Total (3) ports, (1) dedicated for IPMI
Chipset Winbond W83793G
Temperature Monitors temperature for CPU & system environment
LED
Fan fail LED indicator / Over temperature warning
indicator
System
Monitoring
(per blade)
Others Chassis intrusion detection / Watchdog timer support
Onboard
Chipset
Onboard Aspeed AST2050
AST2050 IPMI
Feature
IPMI 2.0 compliant baseboard management controller
(BMC) / USB 2.0 virtual hub / BIOS update
Server
Management
(per blade)
AST2050 iKVM
Feature
24-bit high quality video compression / Dual 10/100 Mb/s
MAC interfaces
Brand / ROM
size
AMI / 4MB
BIOS (per
blade)
Feature
Multiple boot options / Plug and Play (PnP) /PCI2.3
/WfM2.0 /SMBIOS2.3 /PXE boot / ACPI 2.0 power
management /Power on mode after power recovery /
User-configurable H/W monitoring / Auto-configurable of
hard disk types
Operating
System
OS supported
list
Please refer to our Web site for the latest update.
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating
Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating
Environment
In/Non-operatin
g Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6
Complaint
Yes
15
http://www.tyan.com
Manual
(1) Quick Ref. Guide / (1) MB User's manual + (1) BB
User's manual
Installation CD (1) TYAN installation CD
Heatsink /
Cooler
(4) LGA1366 CPU heatsinks
Rail kit (1) sliding rail kit for YR290
Package
Contains
Cable
Power
Cord
(2) CCBL-0310, US type power cord / (2) CCBL-0300,
EU type power cord
1.3 Product Model
Model HDD Bays Power supply
B7018Y290D2
(two nodes)
Hot-swap, 16 HDDs (4) 450W
16
http://www.tyan.com
1.4 Standard Parts List
This section describes the B7018Y290D2 package contents and
accessories. Open the box carefully and ensure that all components are
present and undamaged. The product should arrive packaged as
illustrated below.
1.4.1 Box Contents Per Node
(SATA Interface)
Component Description
2U chassis, 2 nodes
(8) hot swap HDD bays per node
TYAN
®
S7018 system board
(pre-installed)
(1) 450W single Power Supply for
SATA interface (pre-installed)
(3) 60x60x38mm System Fan
(pre-installed)
Power Distribution Board
(pre-installed)
M7018-BP2 SATA/SAS HDD
Backplane Board (pre-installed)
M7018-R16-2F1L PCI-E Riser
Card (pre-installed)
M5376 Front Panel Board
(pre-installed)
17
http://www.tyan.com
(SAS Interface)
Component Description
2U chassis, 2 nodes
(8) hot swap HDD bays per node
TYAN
®
S7018 system board
(pre-installed)
(1+1) Redundant Power Supply for
SAS interface (pre-installed)
(3) 60x60x38mm System Fan
(pre-installed)
Power Distribution Board
(pre-installed)
M7018-BP2 SATA/SAS HDD
Backplane Board (pre-installed)
M7018-R16-1F1YR1L PCI-E Riser
Card (pre-installed)
P3202 PCI-E LSI 1068E 3G SAS 8
port HBA (pre-installed)
M5376 Front Panel Board
(pre-installed)
18
http://www.tyan.com
1.4.2 Accessories
If any items are missing or appear damaged, contact your retailer or
browse to TYAN
®
’s website for service: http://www.tyan.com
The web site also provides information of other TYAN
®
products, as
well as FAQs, compatibility lists, BIOS settings, etc.
TYAN
®
Motherboard
Drive CD
Heatsink x4
HDD Screw Pack x4
Riser Card Power Cable for
SAS Interface
(CCBL-136N)
AC Power Cord 125V
(US)
AC Power Cord 250V
(Europe)
Barebone Manual Mainboard Manual
NOTE:
The TYAN Driver CD does not contain the P3202 LSI 1068E 3G SAS HBA
driver. To obtain the driver for LSI 1068E, please visit the LSI Web site at
http://www.lsi.com/storage_home/products_home/standard_product_ics/sa
s_ics/lsisas1068e/index.html?remote=1&locale=EN
19
http://www.tyan.com
Ultra-slim DVD-ROM
DVD Bracket DVD-ROM Screw Pack
Rail Kit
Rail x2 Screw Pack
20
http://www.tyan.com
1.5 About the Product
The following overview illustrations show you the features of the product.
1.5.1 System Front View (Per Node)
HDD LED Description
Activity LED: Off
Fault LED: Off
No HDD activity
Activity LED: blinking green
Fault LED: Off
HDD activity
Activity LED: Off
Fault LED: Red
HDD Fail
Activity LED: random
Fault LED: blinking red @ 4 Hz
Identify
Activity LED: random
Fault LED: blinking red @ 1 Hz
Rebuild
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Tyan B7018Y290D2 User manual

Category
Server barebones
Type
User manual

Tyan B7018Y290D2 is a highly optimized rack mount barebone system, designed to support up to (2) Intel Xeon 5500 Series processors and up to 96GB RDIMM or 48GB UDIMM DDR3-800/1066/1333 memory per node. Utilizing advanced technology from Intel®, the B7018Y290D2 system provides scalable 32/64-bit computing, high bandwidth memory design, and lightning-fast PCI-E bus capabilities. The B7018Y290D2 not only manages today’s IT environments, but also lays a strong foundation for future growth and expansion as your business needs increase.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI