Dometic VacuFlush, MasterFlush Installation guide

Type
Installation guide
Touchpad Installation
for VacuFlush
®
and MasterFlush
®
electronic-flush toilets
2 in.
(51 mm)
0.10 in.
(2 mm)
dia.
1.375 in.
(35 mm)
2.625 in. (67 mm)
3.25 in. (83 mm)
1 in. (25 mm)
2 in. (51 mm) clearance
behind wall surface required
1. Plan touchpad location so wiring cable can
reach toilet base circuit board. Be sure cable
cannot get wet.
2. Using template (below), mark center access
and fastener holes. Drill 1 in. (25 mm) center
access hole, then fasten touchpad bracket to
wall (g.
1
).
3. Route touchpad cable through wall access
hole to oor access hole at toilet base.
4. Attach cable to back of touchpad, then snap
the touchpad onto the bracket (g.
1
).
5. WITH ELECTRICAL POWER OFF, connect
wiring cable from the touchpad to the RJ45
connector on the circuit board of the toilet
base (g.
2
).
2
1
Caution!
If replacing a different style electronic
ush switch, WITH ELECTRICAL POWER
OFF, be sure to disconnect wiring from old
switch before installing new touchpad.
Dometic Corporation, Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611 USA
1-800-321-9886 • Fax: 330-496-3097
www.Dometic.com
REVISION A
Form No. 600346526 9/17
©2017 Dometic Corporation