2-1. Electronic Malfunction Troubleshooting Chart -C576R 16”
Malfunction Circumstance Inspection and testing Components to replace
No start Display is not lit; display
shows no reaction and
does not light up.
1.Inspect the switch and the fuse wire
2.Check if all the cable is well-connected
3.Check the Display set
4.Inspect or replace Eup board, power board or the
Drive Board
1. Power switch, fuse
2. Display set
3. Eup board or Power board
4. Drive Board
No RPM Start exercising on the
unit; the display shows no
reaction; RPM values on
the display do not change.
1. Check if all the bus line is well-connected
2. Check or Clean the Speed sensor
3. Is the distance between the speed sensor and
the optical disk 5mm?
4. Replace the Driver Board
1.Speed sensor
2.Drive board
No resistance Press resistance up or
down keys; resistance
values change on the
display; but there is no
resistance.
1.Display idle.. Re-start the switch.
2.Check if the RPM value is displayed.
3.Check Electromagnet wire connection.
4.Check or Replace the Drive board set
1. Drive board
Wireless
(telemetry)
heart rate
malfunction
Wireless (telemetry) heart
rate malfunction
1. Replace polar heart rate transmitter.
2. Check or replace the Polar heart rate board
3. Check if there is any interference such as the
light or the speaker.
4. Replace control board.
1.Polar heart rate transmitter
2.Polar heart rate board
3.control board
HTR heart rate
Malfunction.
HTR heart rate
Malfunction.
1.Inspect the HTR cable connection.
2.Inspect the HTR LED indicators.
3.Replace the HTR board.
1.HTR board
2.HTR sensor plate
3.HTR cable
TV function
malfunction.
Cannot watch TV. 1. Check the signal source of the TV
2. Inspect TV settings and each scan all available
TV channels
3. Replace the TV board
4. Replace the Mainboard
1.TV board
2.Mainboard
2-1-1