DKS Remote Alarm / Reset Station User manual

Type
User manual
Remote Alarm / Reset Station
Operator Board Connections
1404-065-F-7-11
DoorKing Part Number
1404-080
Copyright 2011 DoorKing, Inc. All rights reserved.
The Alarm/Reset station provides a remotely mounted entrapment alarm and reset button for slide, swing and overhead gate
operators that utilize DoorKing 4402, 4403, 4404, 4405, 4502, 4602 and 4702 operator control boards.
Make sure that power to the operator is OFF before wiring the remote station.
This Remote
Alarm/Reset
control station
MUST be
mounted in the
Line-of-Site of
the gate and
gate operator!
DO NOT reset
an alarm that
has been
tripped before
visually
inspecting the
gate area for
problems.
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
213
45
White (Com Connection)
Red (Alarm Connection)
Reset
Button
Alarm
Light
Alarm
Siren
Remote
Station
Terminal
Blue (Reset Connection)
6
Use 18 AWG wire.
Control
Board #
Operator Model
Remote Station Terminal White
(4) Red (5) Blue (6)
Operator Terminal
Connections
4402
4403
4404
4405
4502
4602
4702
1150, 9200, 9300
9310
9210, 9220, 9230, 9530, 9550
6500
6050, 6100, 6300
9100, 9150
9050, 9070
1
13
13
13
18
12
2
14
14
14
12
3
15
15
15
11
Aux Terminal
Common (3)
Aux Terminal
Alarm (1)
Aux Terminal
Reset (2)
Aux Terminal
Alarm (6)
Aux Terminal
Reset (5)