Rheem PROTECH SP14904A Operating instructions

Type
Operating instructions

Rheem PROTECH SP14904A is a versatile and efficient water heater that offers numerous benefits for residential use. Its advanced features include:

  • High efficiency: The Rheem PROTECH SP14904A boasts a high energy factor of 0.67, indicating its ability to minimize energy consumption and reduce utility bills.

  • Extended lifespan: With a durable construction and corrosion-resistant materials, this water heater ensures a long-lasting performance, providing years of reliable hot water.

  • Quick recovery: The Rheem PROTECH SP14904A features a fast recovery rate, ensuring a consistent supply of hot water even during periods of high demand.

Rheem PROTECH SP14904A is a versatile and efficient water heater that offers numerous benefits for residential use. Its advanced features include:

  • High efficiency: The Rheem PROTECH SP14904A boasts a high energy factor of 0.67, indicating its ability to minimize energy consumption and reduce utility bills.

  • Extended lifespan: With a durable construction and corrosion-resistant materials, this water heater ensures a long-lasting performance, providing years of reliable hot water.

  • Quick recovery: The Rheem PROTECH SP14904A features a fast recovery rate, ensuring a consistent supply of hot water even during periods of high demand.

!
CAUTION: The burner chamber is a sealed area. If
the burner access door is removed, the burner
access door gasket must be replaced. This should
only be done by a qualified service technician.
INSPECT SHIPMENT:
Inspect contents for possible missing or damaged compo-
nents. This kit includes:
Qty. 1 (one) – Intelli-Vent
Combination Gas Control
See Figure 1
Qty. 1 (one) – Installation
Instructions
TOOLS REQUIRED:
3/4 Open-end wrench
Pipe Wrench
1/2" NPT Pipe (8" to 12" recommended)
Pipe Thread Sealant (Certified for use with Natural and LP
Gas/Liquefied Petroleum Gases)
NOTICE: Compounds used on threaded joints of gas piping
shall be resistant to the action of Liquefied Petroleum Gases.
ADDITIONAL INSTRUCTIONS:
Refer to the Use and Care Manual supplied with the water
heater for complete information on the installation, lighting
instructions, operation and maintenance of the water heater.
1. TO TURN OFF ELECTRIC POWER AND GAS
SUPPLY TO THE WATER HEATER:
Turn off and disconnect all electrical power to the water heater.
Set the combination gas control to its lowest setting by press-
ing the COOLER and HOTTER buttons at the same time for
one second allowing the temperature light indicator to activate.
Depress the COOLER button until the VACATION indicator
light is displayed. Shut off the gas supply at the main gas sup-
ply line. Refer to the lighting instructions label located above
the water heaters combination gas control and the Use and
Care manual for additional information on shutting off the gas
supply.
2. DRAINING THE WATER HEATER:
Shut off the inlet water supply to the water heater. Connect
one end of a garden hose to the water heater’s drain valve and
route the other end to a drain or suitable draining area. Open a
hot water faucet to allow air to flow into the water heater tank
and then open the drain valve. See Figure 2.
3. DISCONNECTION OF BURNER SUPPLY TUBE
FROM THE COMBINATION GAS CONTROL:
Disconnect the wire funnel from the control valve. Disconnect
the wire funnel, six wire Molex connector, four wire Molex
connector, and green ground wire. Using a 3/ 4” open-end
wrench, disconnect the burner supply tube from the control.
See Figure 2.
NOTICE: LP Gas Combination Controls use left-handed
threads on the burner supply tube nut.
4. COMBINATION GAS CONTROL REMOVAL:
With the gas supply shut off, disconnect the main gas supply
piping from the combination gas control. After the water
heater is completely drained, screw a suitable length of 1/2
inch NPT pipe into the gas inlet connection of the combina-
tion gas control. Rotate the control counter clockwise 4
until removed. Remove the section of 1/2" NPT pipe. See
Figure 3.
INSTALLATION INSTRUCTIONS
White-Rodgers Intelli-Vent
®
Combination Gas Control Replacement Kit
[Flammable Vapor Ignition Resistant (FVIR) Models]
Read these instructions thoroughly and understand all steps and procedures before
proceeding with the installation.
1
AP14759 (07/09)
To review or adjust temperature
Step 1. Press the two temperature arrows at the same time for 1 second.
Step 2. To adjust press COOLER or HOTTER arrow for desired temperature.
Temperature light will automatically turn o in 30 seconds.
WARNING
Scald Hazard
Shock Hazard
Explosion Hazard
Severe injury or death can result.
Hotter water increases the risk of scald injury.
No serviceable parts. Do not attempt to disassamble the control.
Do not use tools on the control or otherwise hit or damage the control.
Replace the control if it has been ooded.
This control has self-diagnostics--refer to owner's manual for diagnostic
Intelli-Vent
HOTTER
COOLER
VERY
HOT
WARM
VACATION
A
B
C
WHITE-RODGERS
VACATION
WARNING
VERY
HOT
WARM
A B C
COOLER
HOTTER
Figure 2
Figure 1
Ground Wire (green)
Wire Harness
Opening
Drain Valve
Molex connections:
4 wire & 6 wire
Wire funnel
Burner supply
tube
To review or adjust temperature
Step 1. Press the two temperature arrows at the same time for 1 second.
Step 2. To adjust press COOLER or HOTTER arrow for desired temperature.
Temperature light will automatically turn o in 30 seconds.
WARNING
Scald Hazard
Shock Hazard
Explosion Hazard
Severe injury or death can result.
Hotter water increases the risk of scald injury.
No serviceable parts. Do not attempt to disassamble the control.
Do not use tools on the control or otherwise hit or damage the control.
Replace the control if it has been ooded.
This control has self-diagnostics--refer to owner's manual for diagnostic
Intelli-Vent
HOTTER
COOLER
VERY
HOT
WARM
VACATION
A
B
C
WHITE-RODGERS
Figure 3
1/2 " NPT pipe
Wire funnel
Gas Supply Inlet
Gas Supply Inlet
5. INTELLI-VENT
®
COMBINATION GAS CONTROL
INSTALLATION:
Ensure the replacement combination gas control is correct
for the gas usage of the water heater. Hand start threading
the control into the water heater. Install the suitable length
of 1/2 inch NPT pipe previously used to the gas inlet of new
control. Rotate the control by turning clockwise 3 until the
control is tight and in the upright position.
6. CONNECTION OF BURNER SUPPLY TUBE, MOLEX
CONNECTORS AND GROUND WIRES:
Install the inverted flare end of the burner supply tube into
the combination gas control. Hand thread the hex nut fitting
on the burner supply tube into the control. Ensure that the
fitting is properly aligned with the control, otherwise cross
threading of the connection will occur. Tighten the fitting
using a ¾” open-end wrench. Thread the Molex connectors
through the wire funnel. Connect the four (4) wire Molex
connector to the four (4) pin connector on the bottom of the
control. Connect the six (6) wire Molex connector to the six
(6) pin connector on the bottom of the control. Connect the
wire funnel to the control valve. Connect the green ground
wire to the electricial connector on the side of the control.
See Figure 2.
7. CONNECTION OF THE MAIN GAS SUPPLY TO THE
COMBINATION GAS CONTROL:
Reconnect the main gas supply piping to the combination
gas control. Use pipe thread sealant certified for use with
Natural and LP Gas/Liquefied Petroleum Gases.
NOTICE: Compounds used on threaded joints of gas pip-
ing shall be resistant to the action of liquefied petroleum
gases.
8. REFILLING THE WATER HEATER:
Disconnect the garden hose from the water heater’s drain
valve. Close the drain valve and turn on the inlet water
supply to the water heater. Open all hot water faucets to
allow all trapped air to escape. Let the water heater fill until
a steady stream of water is observed coming from all hot
water faucets then close all faucets.
9. TURN ON ELECTRIC POWER AND GAS SUPPLY
TO THE WATER HEATER:
Reconnect the electrical power to the water heater. Turn on
the main electrical power and gas supply to the water heater.
Check for leaks on the inlet supply piping using a soap and
water solution.
NOTICE: If the soap and water solution bubbles up, there
is a leak and the inlet gas supply piping must be tightened
and checked again.
10. LIGHTING AND OPERATION INSTRUCTIONS:
Follow the “FOR YOUR SAFETY READ BEFORE
OPERATING” and “LIGHTING INSTRUCTIONS” on the
label(s) affixed above the combination gas control.
With the main burner in operation, use a soap and water
solution to check for gas leaks at the burner supply tube
connections.
NOTICE: If the soap and water solution bubbles up, there
is a leak and the fittings must be tightened and checked
again.
IMPORTANT: If the leak(s) cannot be eliminated, turn off
the electrical power and gas supply to the water heater, and
contact the water heater manufacturer at 1-800-432-8373.
11. TEMPERATURE SETTING:
!
DANGER: Hotter water increases the potential for Hot
Water SCALDS.
A temperature setting of 120° F (49°C) or less is recom-
mended as a useable water temperature.
Set the combination gas control to its lowest setting by
pressing the COOLER or HOTTER buttons at the same
time for one second allowing a temperature light indicator
to activate. Depress the COOLER or HOTTER button until
the 120°F ternperature indicator light is displayed.
The illustration in Figure 4 shows the recommended tem-
perature setting.
2
Figure 4
VACATION
WARNING
VERY
HOT
WARM
A B C
COOLER
HOTTER
Temperature Setting
'LVSOD\ź$%&
Burns on Adult Skin
WARM = approx. 70°F (21°C) Ɣżżżżż --------------------
ź DSSUR[)& żżƔżżż More than 5 minutes
A = approx. 130°F (54°C) żżżƔżż About 30 seconds
B = approx. 140°F (60°C) żżżżƔż Less than 5 seconds
C = approx. 150°F (66°C) żżżżżƔ About 1-1/2 seconds
C-Flashing = approx. 160°F
(71°C)
żżżżżƔ About 1/2 seconds
  • Page 1 1
  • Page 2 2

Rheem PROTECH SP14904A Operating instructions

Type
Operating instructions

Rheem PROTECH SP14904A is a versatile and efficient water heater that offers numerous benefits for residential use. Its advanced features include:

  • High efficiency: The Rheem PROTECH SP14904A boasts a high energy factor of 0.67, indicating its ability to minimize energy consumption and reduce utility bills.

  • Extended lifespan: With a durable construction and corrosion-resistant materials, this water heater ensures a long-lasting performance, providing years of reliable hot water.

  • Quick recovery: The Rheem PROTECH SP14904A features a fast recovery rate, ensuring a consistent supply of hot water even during periods of high demand.

Ask a question and I''ll find the answer in the document