Manley HP-100 D-SUB PINOUT Notes Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Manley HP-100 D-SUB PINOUT Notes Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
2
3
4
5
6
7
8
9
10
11
12
13
15
16
17
20
21
22
24
GROUND
CH 1 HI
CH 2 HI
CH 3 HI
CH 4 HI
CH 5L HI
CH 5R HI
CH 6L HI
CH 6R HI
GROUND
14
CH 1 LOW
CH 2 LOW
CH 3 LOW
CH 4 LOW
19
CH 5L LOW
CH 5R LOW
CH 6L LOW
CH 6R LOW
23
LOGIC A
LOGIC B
25
25
23
19
14
24
22
21
20
18
17
16
15
13
12
11
10
9
8
7
6
5
4
3
2
1
25
MON OP R
LOGIC B
LOGIC A
23
CH 6R LOW
CH 6L LOW
CH 5R LOW
CH 5L LOW
19
CH 4 LOW
CH 3 LOW
CH 2 LOW
CH 1 LOW
14
INT MIC OP
MON OP L
GROUND
CH 6R HI
CH 6L HI
CH 5R HI
CH 5L HI
CH 4 HI
CH 3 HI
CH 2 HI
CH 1 HI
GROUND
24
22
21
20
18
17
16
15
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
10
11
12
13
15
16
17
18
20
21
22
24
14
19
23
25
FEMALE SUB D PIN-OUT
MALE SUB D PIN-OUT
A
MALE
FEMALE
1
3
2
4
+22V (28V NO LOAD)
-22V (28V NO LOAD)
4700/35V
40V C.T. @.3A
POWER SUPPLY
THIS SUPPLY LIMITS THE POWER AND VOLTAGE TO THE STATION TO PREVENT
HEADPHONE AND HEARING DAMAGE. UP TO +/- 35V SUPPLIES ARE POSSIBLE IF LOW
EFFICIENCY HEADPHONES ARE USED OR MORE POWER IS NEEDED.
A: CONNECT IF STATIONS WILL BE "AC GROUND" LIFTED AND/OR
MONITOR OF INTERNAL MICS AND L/R OUTPUTS ARE TO BE
USED VIA A CENTRAL PANEL.
NOTE: -10V TO -15V ON LOGIC A FIRES TALK RELAY
   -10V TO -15V ON LOGIC B FIRES INT RELAY
  SHORTING LOGIC A TO LOGIC B FIRES TALK RELAY
NOTE: 12, 13 AND 25 ARE NOT USED AT THE     
   MALE SUB D TO PREVENT TWO LINKED    
   OUTPUTS FROM DRIVING EACH OTHER
NOTE:1/4" JACKS ARE DIRECTLY CONNECTED TO SUB D
   CONNECTORS (PARALLELED) AND WILL NOT BREAK
   A CONNECTION. CONSIDER NOT WIRING ONE PAIR
   IF A LOCAL SOURCE IS TO BE USED ALSO.
LANGEVIN
HPA-100
EXT TB HI
18
EXT TB LOW
EXT TB HI
EXT TB LOW
NOTE: MOST COMMUNICATION NEEDS CAN EASILY BE
HANDLED THE TYPICAL WAY BY FEEDING ONE
OF THE INPUTS WITH ONE OF THE CONSOLES
CUE FEEDS. USE PINS 6 & 18 TO RECIEVE THE
STATIONS SWITCHED TALK FUNCTION. PIN 13
SENDS THE UN-SWITCHED INTERNAL MIC.

TYPICAL LINK CABLE WIRING FOR NO GROUND LOOPS
NOTE: SWITCHED INTERNAL MICS WILL APPEAR ON
PINS 6 & 18 FOR LINKED STATIONS. GAIN IS
VARIABLE BY THE SOURCE IMPEDANCE OF THE
CONTROL ROOM MIC AMP (IF USED). IF IT IS
SWITCHED THEN IT WILL BREAK INTO ANY
CONVERSATION. A 10K RESISTOR IN LINE
WITH THE MIC AMP ALLOWS "CONFERENCE
CALLS".

/