Peerless EWMU User manual

Category
Flat panel wall mounts
Type
User manual

This manual is also suitable for

Installation and Assembly:
Wind Rated Tilt Wall Mount for 32" - 65" Outdoor Flat
Panel Displays
Features:
Universal screen mounting brackets hook onto the wall plate for quick, easy, and safe installation
Adjustable up to 15° of forward tilt and up to -5° backward tilt
Includes Sorted-For-You™ fastener pack for installation to wood studs, concrete and cinder block
Optional horizontal adjustment of up to 8" (203 mm) (depending on screen model) for perfect screen placement
Models: EWMU, EWMU-S
Max UL Load Capacity: 200 lb (90.7 kg)
Max Wind Rating: 110 mph, elevation 200 ft (60m), Category "D"
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
©
U
L
USC
2 of 32
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
NOTE: Read entire instruction sheet before you start installation and assembly.
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Double Wood Stud Wall ...................................................................................................................................4
Installation to Solid Concrete or Cinder Block ........................................................................................................................5
Installing Tilt Brackets .............................................................................................................................................................6
Mounting and Removing Flat Panel Screen ...........................................................................................................................7
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Due to outdoor environmental conditions such as strong wind gusts, heavy snow, hail, rain, etc. The environmental
enclosure, together with its mount, extension tube and hardware, must be inspected at least once a year, and
immediately following any time winds exceed 90 mph. A qualifi ed installer or inspector must check for signs of rust,
loose fasteners, bent metal, etc. If evidence of excessive wear, deterioration or any unsafe condition is observed,
this product must be taken out of service immediately. Direct all inquiries to customer care if you have any
questions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum UL Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud fi nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product was designed for use with other outdoor products only.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
Brick Contact Qualifi ed Professional (Not evaluated by UL)
Other or unsure? Contact Qualifi ed Professional (Not evaluated by UL)
WARNING
Tools Needed for Assembly
• stud fi nder ("edge to edge" stud fi nder is recommended)
• phillips screwdriver
• drill
• 5/16" (8 mm) bit for concrete and cinder block wall, 5/32" (4 mm) bit for wood stud wall
• level
3 of 32
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
D
FGH KIJ
A
B
C
L
Parts may appear slightly different than illustrated.
Before you begin, make sure all parts shown are included with your product.
EWMU EWMU-S
Description Qty. Part # Part #
A
wall plate
1
061-T1258
061-7258
B left tilt bracket 1 061-T1383 061-7383
C right tilt bracket 1 061-T1382 061-7382
D
wood screw
4 520-5033 520-5033
E concrete anchor 4 590-0320 590-0320
F
M6 x 12 mm socket pin screw
4 520-5023 520-5023
G M6 x 25 mm socket pin screw 4 520-5024 520-5024
H M8 x 15 mm socket pin screw 4 520-5026 520-5026
I M6 x 20 mm socket pin screw 4 520-5025 520-5025
J M8 x 25 mm socket pin screw 4 520-5027 520-5027
K
washer
4 540-5014 540-5014
L
4 mm securit
y
allen wrenc
h
1560-964
6
560-964
6
Parts List
E
4 of 32
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
Use a stud fi nder to locate the edges of the studs. Use of an edge-to-edge stud fi nder is highly recommended.
Based on their edges, draw a vertical line down each stud’s center. Place wall plate (A) on wall as a template.
The top mounting slots should be located 1.76" (45 mm) above the desired screen center as shown in fi gure 1.1.
Level plate, and mark the center of the four mounting holes. Make sure that the mounting holes are on the stud
centerlines. Drill four 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make sure that the wall plate is level, secure it
using four #14 x 2.5" wood screws (D) as shown in fi gure 1.2.
Skip to step 2.
1
g. 1.1
CS = center of screen
A
STUD
D
A
g. 1.2
CS
1.76"
(45 mm)
Installation to Double Wood Stud Wall
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations (Not evaluated by UL).
WARNING
5 of 32
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
Make sure that wall plate (A) is level, use it as a
template to mark four mounting holes. The top
mounting slots should be located 1.76" (45 mm)
above the desired screen center as shown in
gure 1.1 on page 4. Drill four 5/16" (8 mm) dia.
holes to a minimum depth of 2.5" (64 mm). Insert
anchors (E) in holes fl ush with wall as shown
(right). Place wall plate over anchors and secure
with #14 x 2.5" screws (D). Level, then tighten all
fasteners.
SOLID CONCRETE
CINDER BLOCK
1
Installation to Solid Concrete or Cinder Block
A
D
E
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
• Tighten screws so that wall plate is fi rmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
nishing material. If mounting to concrete surfaces
covered with a fi nishing surface is unavoidable (Not
evaluated by UL), the fi nishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16 mm), custom fasteners must be supplied
by installer (Not evaluated by UL).
WARNING
CUTAWAY VIEW
INCORRECT CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
E
Drill holes and insert anchors (E).
Place enclosure (A) over anchors (E) and secure with screws (D).
Tighten all fasteners.
A
E
D
CONCRETE
SURFACE
6 of 32
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
To prevent scratching the screen, set a cloth on a fl at, level surface that will support the weight of the screen.
Place screen face side down. If screen has knobs on the back, remove them to allow the adapter brackets to be
attached. Place adapter brackets (B,C) on back of screen, align to holes, and center on back of screen as shown
below. Attach the adapter brackets to the back of the screen using the appropriate combination of screws and
washers and as shown in step 2-1.
NOTE: Top and bottom mounting holes on screen must be used for attaching brackets.
NOTE: Be sure to attach tilt brackets with tilt adjustment screw facing outward as shown below.
Verify that all holes are properly aligned, and then tighten screws using 4 mm allen wrench (L).
NOTE: "X" dimensions should be equal.
CENTER BRACKETS
VERTICALLY ON BACK
OF SCREEN
X
X
TILT
ADJUSTMENT
SCREW
2
Installing Tilt Brackets
B
C
Begin with the shortest length screw, hand thread
through washer and tilt bracket into screen as
shown. Screw must make at least three full turns
into the mounting hole and fi t snug into place.
Do not over tighten. If screw cannot make three
full turns into the screen, select a longer length
screw from the baffl ed fastener pack. Repeat for
remaining mounting holes, level brackets and
tighten screws.
2-1
TILT BRACKET
(B,C)
SCREEN
WASHER
SCREW
• Tighten screws so adapter brackets are fi rmly attached. Do not tighten with excessive force. Overtightening
can cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to
become detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque.
• If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly
secured, damage may occur to screen or product may fail.
WARNING
7 of 32
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
© 2010, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.
DETAIL 3
g 4.1
IncreLok™
TILT
SCREW
TILT
POSITION
HOLES
LOCATOR
HOLE
LOCKING
SCREW
g 3.2
g 3.1
A
B,C
DETAIL 1
Mounting Screen: Hook tilt brackets (B,C) onto
wall plate (A) and swing screen in as shown in fi g.
3.1. NOTE: If the security clip does not clear the
bottom of the wall plate, loosen the security screw
with allen wrench (L). Tilt bracket hooks must fully
engage wall plate as shown in detail 1. Tighten
security screw using allen wrench (L) until security
clip sits fi rmly against bottom of wall plate.
NOTE: Be sure security clip is secured to bottom
of wall plate as shown in detail 2.
Removing Screen: Loosen security screw from
security clip until the screen is able to swing freely,
and lift screen off of mount.
Screen Adjustment: Screen can be adjusted
horizontally by loosening security screw three full
turns using allen wrench (L). Adjust screen as
shown in fi gure 3.2. Tighten security screw.
NOTE: Choosing and setting tilt position may be
easier before placing screen onto wall mount.
INCRELOK™: The screen can be locked into a
pre-set tilt position of -5°, 0°, 5°, 10° or 15°. Use
locator hole to fi nd tilt position hole and tilt screen
to align holes. Tighten IncreLok™ tilt screws on
both tilt brackets as shown in detail 3.
Tighten locking screw to lock down tilt position.
Mounting and Removing Flat Panel Screen
Adjusting the Tilt Angle of the Flat Panel
Screen
SECURITY
SCREW
SECURITY
CLIP
3
4
• Always use an assistant or mechanical lifting equip-
ment to safely lift and position the fl at panel screen.
• Do not tighten screws with excessive force.
Overtightening can cause damage to mount. Tighten
screws to 40 in. • lb (4.5 N.M.) maximum torque.
• Be careful not to pinch fi ngers when pushing screen
from the bottom.
WARNING
DETAIL 2
29 of 32
ISSUED: 06-22-10 SHEET #: 061-9052-6 01-15-11
© 2008 Peerless Industries, Inc.
Peerless Industries, Inc. establishes a warranty period of fi ve years for products manufactured or supplied by Peerless. This period commences from the date of
sale of the product to the original consumer, but will in no case last for more than six years after the date of the product’s manufacture. During the warranty period
such products will be free from defects in material and workmanship, provided they are installed and used in compliance with the instructions established by
Peerless Industries, Inc. Subject to applicable legal requirements, during the warranty period Peerless will repair or replace, or refund the purchase price of, any
such product which fails to conform with this warranty.
Any other warranties prescribed by the law which may apply with respect to such products also are limited in duration to the warranty period specifi ed in this
Limited Five-Year Warranty.
This warranty does not cover damage caused by (a) service or repairs by the customer or a person who is not authorized for such service or repairs by Peerless
Industries, Inc., (b) the failure to utilize proper packing when returning the product, (c) incorrect installation or the failure to follow Peerless’ instructions or warnings
when installing, using or storing the product, or (d) misuse or accident, in transit or otherwise, including in cases of third party actions and force majeure.
In no event shall Peerless be liable for incidental or consequential damages or damages arising from the theft of any product, whether or not secured by a security
device which may be included with the product.
This Limited Five-Year Warranty is in lieu of all other warranties, expressed or implied, and is the sole remedy with respect to product defects. No retailer, dealer,
distributor, installer or other person is authorized to modify or extend this warranty or impose any obligation on Peerless in connection with the sale of any product
manufactured or supplied by Peerless.
This warranty gives specifi c legal rights, and you may also have other rights provided by the national legislation of the country in which you purchased such
product.
LIMITED FIVE-YEAR WARRANTY
www.peerlessmounts.com
© 2008 Peerless Industries, Inc.
Limited one-year warranty on corrosion.
LIMITED ONE-YEAR WARRANTY
www.peerlessmounts.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Peerless EWMU User manual

Category
Flat panel wall mounts
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document