Unbranded R6GF-B Product information

Type
Product information
CCH
IF
EQUIPPED
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
240V
208V
24V
COM
1
2
3
1
2
3
HILO
PRIMARY
GAS VALVE
C
A1 W2Y2
R C
Y1 G W1
54321
54321
VARIABLE
SPEED
BLOWER
MOTOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
R
S
C
R
S
C
CHF
TO 208/230 VAC
POWER SUPPLY
FLAME ROLL-OUT
FLAME
SENSOR
HPS
LOW PRESSURE
SWITCH
HIGH
PRESSURE
SWITCH
L2 L1
T1T2
YE/BK
2
1
3
6
5
4
78
9
12
11
10
W1
W2
C
R
G
Y
Y2
0
DEHUM
P2
1
5
LPS
TRANSFORMER
HIGH TEMP
LIMIT
OUTDOOR
FAN MOTOR
DUAL
CAPACITOR
ECONOMIZER JUMPER
HARNESS ASSY. 8-WIRE
IGNITOR
INDUCER
MOTOR
HUM
LINE
XMFR
CONT
EAC
COOL
PARK1
PARK2
HI-HEAT
LO-HEAT
NEUTRALS
P6 16-PIN
ECONOMIZER
PLUG
ECONOMIZER
PLUG
(CFM)
YEL
GREEN
HI/LO
DEHUMIDIFY
IGNITION / BLOWER
CONTROL BOARD
(HIGH HEAT
DEMAND)
GREEN
(STATUS)
RED
AUTO
HEAT STAGE
10 5 NONE
COOL
A B C D
HEAT
A B C D
ADJUST
NORM
(+)
(-)
TEST
5A FUSE
21 3
BK/WH
RED
AIR SENSOR
TO DISCHARGE
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
RED
COMPRESSOR
RED
YELLOW
YELLOW
RED
YELLOW
VIOLET
YELLOW
GRAY
BLACK
CONTROL WIRING LEADS
Refer to Installation Instructions for
Connection to Indoor Thermostat
BROWN
BROWN
BLACK
WHITE
RED
Note: See Installation Instructions
for specic blower speed setting.
WHITE
WHITE
WHITE
ORANGE
BLUE
BLUE
GREEN
BLACK
BLACK
BROWN
BLACK
WHITE
RED
YELLOW
BLUE
GREEN
BLACK
RED
BROWN
RED
BLACK
WHITE
GREEN
YELLOW
BLUE
BROWN
BLACK
RED
BLACK
YELLOW
YELLOW
RED
RED
ORANGE
BLUE
YELLOW
BLACK
GRAY
GREEN
BLACK
BLUE
GREEN
YELLOWYELLOW
BLACK
GREEN
SEE NOTE 6.
BLACK
BLUE
YELLOW
ORANGE
RED
YELLOW
RED
BROWN
BROWN
BLUE
BLUE
WHITE
WHITE
WIRING DIAGRAM
208/230 Volt Single PhasePackaged Two Stage Heat/Two Stage Electric Air Conditioner
60Hz
WIRING DIAGRAM
NOTES:
1. Disconnect power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V
a la terre.
4. If any of the original wire as supplied with the furnace must be replaced, it must
be replaced with wiring material having a temperature rating of at least 105°C.
5. For supply wire ampacities and overcurrent protection, see unit rating plate.
6.For 208V operation,inducer motor low speed resistor must be bypassed.
Removed RED wire from resistor block and connect to piggyback terminal
on opposite side.
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
SYSTEM STATUS - IGNITION
Power On (Normal Operation)
High Limit Circuit Open
Pressure Switch Open with Inducer On
Pressure Switch Closed with Inducer O
Failed Ignition (5 attemps) - Control in 1 Hour Lockout
208-230 Volt Polarity Issue
Excess High limit trips (5) within one call for heat
Excess pressure switch cycles (5) within one call for heat
Excess ame dropouts (5) within one call for heat
Not Used
Flame present with gas valve O
LED STATUS (RED)
ON
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
9 Flashes
10 Flashes
SYSTEM STATUS - 2nd STAGE HEAT DEMAND
No demand for 2nd stage heat
2nd stage heat demand (Normal operation)
2nd stage heat demand, high pressure switch not closed
LED STATUS (GREEN)
OFF
ON
Flashing
SYSTEM STATUS - CFM
NOT USED
LED STATUS (YELLOW)
OFF
SYSTEM STATUS - HI/LO DEHUMIDIFY (Cooling Mode only)
Factory jumper wire “R” to “DEHUM” in place or
“Close on Fall humidistat (Low humidity) - Closed
Humidistat open (High Humidity) Low Speed Blower call
LED STATUS (GREEN)
ON
OFF
10034830
11/14
GAS VALVE
624787
  • Page 1 1

Unbranded R6GF-B Product information

Type
Product information

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI