Reznor R6GF Product information

Type
Product information

Reznor R6GF Gas-fired unit heater that features a durable steel cabinet, aluminized steel heat exchanger, and direct spark ignition system. It's designed to provide efficient, reliable heating for a variety of commercial and industrial applications, including factories, warehouses, garages, and workshops. The R6GF offers a range of heating capacities, making it suitable for spaces of various sizes. It's also equipped with safety features such as a flame rollout switch and high-temperature limit control to ensure safe operation.

Reznor R6GF Gas-fired unit heater that features a durable steel cabinet, aluminized steel heat exchanger, and direct spark ignition system. It's designed to provide efficient, reliable heating for a variety of commercial and industrial applications, including factories, warehouses, garages, and workshops. The R6GF offers a range of heating capacities, making it suitable for spaces of various sizes. It's also equipped with safety features such as a flame rollout switch and high-temperature limit control to ensure safe operation.

CCH
IF
EQUIPPED
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
240V
208V
24V
COM
1
2
3
1
2
3
HILO
PRIMARY
GAS VALVE
C
L W2Y2
R C
Y1 G W1
54321
54321
VARIABLE
SPEED
BLOWER
MOTOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
R
S
C
R
S
C
CHF
TO 208/230 VAC
POWER SUPPLY
FLAME ROLL-OUT
FLAME
SENSOR
HPS
LOW PRESSURE
SWITCH
HIGH
PRESSURE
SWITCH
L2 L1
T1T2
2
1
3
6
5
4
78
9
12
11
10
W1
W2
C
R
G
Y
Y2
0
DEHUM
P2
1
5
LPS
TRANSFORMER
HIGH TEMP
LIMIT
OUTDOOR
FAN MOTOR
DUAL
CAPACITOR
AIR SENSOR
TO DISCHARGE
ECONOMIZER JUMPER
HARNESS ASSY. 8-WIRE
IGNITOR
BROWN
BROWN
INDUCER
MOTOR
BLACK
BLUE
BLUE
BLUE
YELLOW
ORANGE
YELLOW
HUM
LINE
XMFR
CONT
EAC
COOL
PARK1
PARK2
HI-HEAT
LO-HEAT
NEUTRALS
P6 16-PIN
ECONOMIZER
PLUG
ECONOMIZER
PLUG
(CFM)
YEL
GREEN
HI/LO
DEHUMIDIFY
IGNITION / BLOWER
CONTROL BOARD
(HIGH HEAT
DEMAND)
GREEN
(STATUS)
RED
AUTO
HEAT STAGE
10 5 NONE
COOL
A B C D
HEAT
A B C D
ADJUST
NORM
(+)
(-)
TEST
5A FUSE
21 3
RED
COMPRESSOR
RED
RED
YELLOW
YELLOW
RED
YELLOW
VIOLET
YELLOW
GRAY
BLACK
CONTROL WIRING LEADS
Refer to Installation Instructions for
Connection to Indoor Thermostat
BROWN
BROWN
BLACK
WHITE
RED
Note: See Installation Instructions
for specific blower speed setting.
BLACK
GREEN
WHITE
WHITE
RED
RED
WHITE
ORANGE
BLUE
BLUE
GREEN
BLACK
BLACK
BROWN
BLACK
WHITE
RED
YELLOW
BLUE
GREEN
BLACK
RED
BROWN
RED
BLACK
WHITE
GREEN
YELLOW
BLUE
BROWN
BLACK
RED
BLACK
YELLOW
YELLOW
RED
RED
ORANGE
BLUE
YELLOW
BLACK
GRAY
GREEN
BK/WH
YE/BK
BLACK
BLUE
GREEN
YELLOWYELLOW
WIRING DIAGRAM
208/230 Volt Single Phase
Packaged Two Stage Heat/Two Stage Electric Air Conditioner
60Hz
WIRING DIAGRAM
NOTES:
1. Disconnect power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V
a la terre.
4. If any of the original wire as supplied with the furnace must be replaced, it must
be replaced with wiring material having a temperature rating of at least 105°C.
5. For supply wire ampacities and overcurrent protection, see unit rating plate.
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
SYSTEM STATUS - IGNITION
Power On (Normal Operation)
High Limit Circuit Open
Pressure Switch Open with Inducer On
Pressure Switch Closed with Inducer Off
Failed Ignition (5 attemps) - Control in 1 Hour Lockout
208-230 Volt Polarity Issue
Excess High limit trips (5) within one call for heat
Excess pressure switch cycles (5) within one call for heat
Excess flame dropouts (5) within one call for heat
Not Used
Flame present with gas valve Off
LED STATUS (RED)
ON
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
9 Flashes
10 Flashes
SYSTEM STATUS - 2nd STAGE HEAT DEMAND
No demand for 2nd stage heat
2nd stage heat demand (Normal operation)
2nd stage heat demand, high pressure switch not closed
LED STATUS (GREEN)
OFF
ON
Flashing
SYSTEM STATUS - CFM
NOT USED
LED STATUS (YELLOW)
OFF
SYSTEM STATUS - HI/LO DEHUMIDIFY (Cooling Mode only)
Factory jumper wire “R” to “DEHUM” in place or
“Close on Fall” humidistat (Low humidity) - Closed
Humidistat open (High Humidity) Low Speed Blower call
LED STATUS (GREEN)
ON
OFF
7111820
(Replaces 7111270)
11/11
HI LO
PRIMARY
GAS VALVE
C
GAS VALVE
624787
GAS VALVE
624652
BROWN
YELLOWYELLOW
BROWN
GRAY
  • Page 1 1

Reznor R6GF Product information

Type
Product information

Reznor R6GF Gas-fired unit heater that features a durable steel cabinet, aluminized steel heat exchanger, and direct spark ignition system. It's designed to provide efficient, reliable heating for a variety of commercial and industrial applications, including factories, warehouses, garages, and workshops. The R6GF offers a range of heating capacities, making it suitable for spaces of various sizes. It's also equipped with safety features such as a flame rollout switch and high-temperature limit control to ensure safe operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI