Unbranded R6GP 6, 7.5 - 10 Ton Archived 2/23/12, R6GP Product information

  • Hello! I am an AI chatbot trained to assist you with the Unbranded R6GP 6, 7.5 - 10 Ton Archived 2/23/12 Product information. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What safety precautions should be taken before servicing the device?
    What type of conductors should be used for supply connections?
    What is the minimum temperature rating required for replacement wire?
    Where can I find information about supply wire ampacities and overcurrent protection?
    What is the purpose of the auto transformer?
    What is the function of the rollout switch?
    What does the ignition control failure code indicate?
    What is the purpose of the flame sensor?
    What is the function of the spark ignitor?
    What does the lockout from too many failed ignition tries indicate?
    What is the purpose of the high-pressure switch?
    What does the flame present with gas off error indicate?
3 Phase 60 Hz.
4. For supply wire ampacities and overcurrent protection, see unit
rating label.
5. On “C” Series Models only. For 208V operation remove wire from
230V tap and place on 208V tap.
6. This wire replaced by auto transformer when used.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
WIRING DIAGRAM
R6GP Series 6-10T
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. If any of the original wire as supplied with the furnace must be replaced,
it must be replaced with wiring material having a temperature rating of
at least 105C and 600V.
CCH - Crankcase Heaters, Stage 1&2 Compressor
CC1&2 - Contactor, Stage 1&2 Compressor
E - Economizer
LVT - Low Voltage Terminal
OFC - Contactor, Outdoor Fan
IBC - Contactor, Indoor Blower Motor
IC - Integrated Control
L1
L2
L3
GND
Compressor 1
T2
T1
T3
CC1
Aux.
Switch
(N.C.)
CC1
CCH1
Field Supplied
Disconnect
(3Phase Power Only)
For supply connections use
copper conductors only.
Unit
Terminal
Block
24V Hot
High
Pressure
Switchs
Evap.
Freezestats
Low
Pressure
Switchs
Y1
Factory
Jumper
LVT-C (24V COM.)
LVT-R
CC1
LVT-Y1(Stage 1 Cool)
LVT-Y2(Stage 2 Cool)
LVT-G
LVT-W1(Heat)
LVT-W2(Heat)
E-1
E-9
E-8
E-2
E-4
E-5
OFC
CC1
Aux. Switch
(N.O.)
IBC
Aux. Switch
(N.O.)
CC2
Aux. Switch
(N.O.)
Y2
Factory
Jumper
WH BK
Inducer Motor
208-230/460 Volt
1
3
1
3
Max
Temp.
Limit
24V Common
Flame
Rollout
Switch
Upper
Scndry
Limit
P1-2
P1-8
P1-3
P2-3
K2
S1
S2
UTEC
IGNITION
CONTROL
G
C
R
L
COM
NC
NO
BLOWER
TIME
DELAY
K1
P2-4
W1
W2
HV
TRANSFORMER
FS
P2-1
COM
P1-9
P1-6
GAS VALVE
INDUCER MTR
CENTRIFUGAL
SWITCH
SPARK
IGNITOR
FLAME
SENSOR
GND
High
Limit
Input
Rollout Switch
Input
C
IBC
T2
T3
T1
IBC
Transformer
24V Sec.
Primary
Indoor Fan Motor
See Note 5
OFC
4 Amp
Circuit
Breaker
Auto Transformer
460V Units Only
L3 L2
See Note 6
P1-7
P1-4
24 VAC
P2-2
R
IC-IND
K4-IC
IC-L1
Status Light
(Red)
Ignition Control Failure Code
Steady On
2 ashes
Operation Normal
3 ashes
4 ashes
5 ashes
6 ashes
7 ashes
8 ashes
9 ashes
10 ashes
Pressure/centrifugal switch open with inducer on
Lockout from too many failed ignition tries
Lockout from too many ame losses
High temperature switch open
Rollout switch open
Flame present with gas o`
Exceeded max limit trips in one call for heat (5)
Gas Valve Fault
Pressure/centrifugal switch closed with inducer o
R
C
Outdoor Fan Motor
Outdoor Fan Motor
S
R
C
S
See Alternate
OD fan wiring
Diagram B
T2
T3
T1
CC2
Compressor 2
Aux. Switch
(N.C.)
CC2
CCH2
711153C
08/14
(Replaces 711153B)
- Indicates plug connection.
Letter Indicates which plug.
Number indicates pin location.
2 Stage Equipment Only
- Indicates screw connection.
CC2
E-14
E-15
TO JADE
C7250A
MIXED AIR
SENSOR
LVT-A1
E-7
/