Vaisala PTU200MIK1 User manual

Type
User manual
USER'S GUIDE
Outdoor Mounting Kit
PTU200MIK1
M210226EN-A
PUBLISHED BY
Vaisala Oyj Phone (int.): +358 9 8949 1
P.O. Box 26 Fax: +358 9 8949 2227
FIN-00421 Helsinki
Finland
Visit our Internet pages at http://www.vaisala.com/
© Vaisala 2006
No part of this manual may be reproduced in any form or by any means, electronic or
mechanical (including photocopying), nor may its contents be communicated to a third
party without prior written permission of the copyright holder.
The contents are subject to change without prior notice.
Please observe that this manual does not create any legally binding obligations for
Vaisala towards the customer or end user. All legally binding commitments and
agreements are included exclusively in the applicable supply contract or Conditions of
Sale.
_________________________________________________________________________________
VAISALA __________________________________________________________________________ 1
Table of contents
CHAPTER 1
GENERAL INFORMATION ............................................................................2
Safety .........................................................................................2
Warranty ....................................................................................2
CHAPTER 2
PRODUCT DESCRIPTION.............................................................................3
CHAPTER 3
PTU200MIK1 INSTALLATION .......................................................................4
Installation when static pressure head is on the right side .5
Installation when static pressure head is on the left side....7
Connections in the transmitter box ........................................8
Probe installations....................................................................9
HMP45 series ........................................................................9
HMP233 series ......................................................................9
HMP243 series ....................................................................10
CHAPTER 4
PTU200TRIPOD INSTALLATION ................................................................11
CHAPTER 5
DIMENSIONS in mm (in inches).................................................................12
Static pressure head on the left side....................................12
Static pressure head on the right side .................................13
USER'S GUIDE_______________________________________________________________________
2 ___________________________________________________________________ NOVEMBER 2001
CHAPTER 1
GENERAL INFORMATION
Safety
Throughout the manual, important safety considerations are
highlighted as follows:
WARNING
Warning denotes a serious hazard. It calls attention to a procedure,
practice, condition or the like, which, if not correctly performed or
adhered to, could result in injury to or death of personnel.
CAUTION
Caution denotes a hazard. It calls attention to a procedure, practice,
condition or the like, which, if not correctly performed or adhered to,
could result in damage to or destruction of part or the entire product.
NOTE
Note highlights important information. It calls attention to an
essential procedure, practice, condition or the like.
Warranty
Vaisala issues a guarantee for the material and workmanship of this
product under normal operating conditions for one (1) year from the
date of delivery. Exceptional operating conditions: damage due to
careless handling and misapplication will void the guarantee.
CHAPTER 2_______________________________________________________ PRODUCT DESCRIPTION
VAISALA __________________________________________________________________________ 3
CHAPTER 2
PRODUCT DESCRIPTION
PTU200MIK1 mounting kit is for outdoor installation of the PTU200 transmitter
and humidity probes HMP45/HMP233 or HMP 243. The kit consists of a protective
transmitter box, a support arms, a radiation shield, the static pressure head, pole
attachment clamps, a pressure pipe, and a pressure hose. The kit can be attached to
any pole with diameter of either 2" or 60 mm. The box offers IP65 protection for
the transmitter. It is airtight and connected to the static pressure head with the
pressure hose. The radiation shield protects the RH/T probe and the static pressure
head reduces the effect of wind on the pressure measurement.
Static pressure head on the right side. Static pressure head on the left side.
Figure 1. Two different installations.
A tripod stand PTU200TRIPOD is for use
with the outdoor mounting kit PTU200MIK1
Due to its collapsible structure, it is easy to
transfer, which ensures quick system set up
even for temporary installations.
PTU200TRIPOD includes an adjustable
tripod stand with a carrying strap and 650
mm pole (Ø 60 mm).
USER'S GUIDE_______________________________________________________________________
4 ___________________________________________________________________ NOVEMBER 2001
CHAPTER 3
PTU200MIK1 INSTALLATION
Plastic bag (2 pcs.) include:
Clamp for pole mounting
Plastic fitting ring
Hex bolt (2 pcs.) M8x40 DIN 931
Washer (2 pcs.) A 8.4 DIN 125
Hex nut (2 pcs.) M8 DIN 934
Allen screw (2 pcs.)
M6x12 DIN 912
Attach the clamp with the machined side
up to the T-profile with the two Allen
screws.
There are three possible positions: left,
centered, right.
Pole diameter:
- Clamps with the fitting ring
2"(-1/8")
- Clamps without the fitting ring
60
(
-5 mm
)
.
Place the cover plate on
the transmitter box and
fasten it with the two slot
headed screws.
Plastic bag includes:
Cover plate
Slot headed screw (2
pcs.) M4x6 DIN 84
Washer (2 pcs.)
A 4.3 DIN 125
CHAPTER 3___________________________________________________ PTU200MIK1 INSTALLATION
VAISALA __________________________________________________________________________ 5
Installation when static pressure head is on the
right side
2.Fasten the installation plate
onto the support arm.
3.Mount the radiation shield
the holes of the installation
plate. Fasten it to the plate
with the slot headed screws
(M5x16 DIN84,provided)
1.Mount the support
arm on the upper
clamp. Use the plate,
two hex bolts and
washers for the
attachement as shown
in figure.
4. Insert the boom adapte
r
into on support arm. Fasten it
with two screws.
Installation plate
Radiation shield
5. Attach the support arms
and fasten with two screws.
Boom
adapter
USER'S GUIDE_______________________________________________________________________
6 ___________________________________________________________________ NOVEMBER 2001
8.Push the installation plate
into the support arm.
6.Thread the pressure
hose through the
support arm.
9.Fasten the static pressure
head to the end of the support
arm (and installation plate) by
usin
g
the two screws.
7.Attach the pressure hose
end to the threaded nipple of
the pressure head.
Threaded
nipple.
10. Connect the free end
of the pressure hose to
the hose coupling on
backside of the
transmitter box.
Note! the tube shall not
hang loose. This is to
prevent the condense
water block the tube as it
freezes.
CHAPTER 3___________________________________________________ PTU200MIK1 INSTALLATION
VAISALA __________________________________________________________________________ 7
Installation when static pressure head is on the
left side
4.Mount the radiation shield
as instructed on page 5.
5. Mount the static pressure
head and thread the pressure
hose as instructed on page 6.
2 Join the two
support arms by
using two screws.
3.Mount the support arm on
the upper clamp. Fasten it by
using the plate, two hex bolts
and washers for the
attachement as shown in the
figure.
6. Connect the free end
of the pressure hose to
the hose coupling on
backside of the
transmitter box.
Note! the tube shall not
hang loose. This is to
prevent the condense
water block the tube as it
freezes.
1. Insert the boom adapte
r
into on support arm. Fasten it
with two screws.
Boom adapte
r
USER'S GUIDE_______________________________________________________________________
8 ___________________________________________________________________ NOVEMBER 2001
Connections in the transmitter box
1.Mount the PTU200 transmitte
r
on the back plate of the
transmitter box and attach it with
the four Allen screws.
2.Thread the cables through the
holes of the box and the gasket
body.
Allen key
for opening
the
transmitte
r
3.Thread the cables through the hole in the
bottom of the box. (The diameter of the
bottom hole is 35 mm)
4.Thread the cables through the different
parts of the gasket fitting in the order
shown in the figure. Take care that the
positions of the parts are correct.
There are two alternative rubber sealings,
one for the cables of 4 and 6 mm and one
for the cables of 6 and 6 mm.
Press the cable through the vertical cutting
of the rubber sealing.
5.After threading the cables, press the
gasket to the fitting body in the bottom of
the box and tighten the nut.
CHAPTER 3___________________________________________________ PTU200MIK1 INSTALLATION
VAISALA __________________________________________________________________________ 9
Probe installations
HMP45 series
HMP233 series
1. Push the HMP45 probe through the
plastic nut to the radiation shield as deep
as it goes. 2. Pull back about 10 mm.
3. Finally, tighten the plastic nut.
1. Attach the HMP233 probe to the support
with an upper cable tie.
2. Press the probe cable into the groove of
the support.
3. Fasten the lower cable tie.
4. Push the probe through the plastic nut
into the radiation shield as deep as it goes.
5. Finall
y
, ti
g
hten the plastic nut.
Sensor head
support
Cable
tie
Plastic nut
USER'S GUIDE_______________________________________________________________________
10 __________________________________________________________________ NOVEMBER 2001
HMP243 series
Senso
head
support
Cable
tie
Plastic nut
1. Attach the HMP243 probe to the support
with an upper cable tie.
2. Press the probe cable into the groove of
the support.
3. Fasten the lower cable tie.
4. Push the probe through the plastic nut
into the radiation shield as deep as it goes.
5. Finall
y
, ti
g
hten the plastic nut.
CHAPTER 4_________________________________________________PTU200TRIPOD INSTALLATION
VAISALA _________________________________________________________________________ 11
CHAPTER 4
PTU200TRIPOD INSTALLATION
Place the pole onto the tripod
stand and fasten it with the
attachment screw. The handle of
the screw is under the center of
the stand.
The legs of the stand are
adjustable. To release the leg, lift
the grip upwards. Adjust the leg
to desired length and lock it by
pressing the grip downwards.
Use the clamps without the fitting
rings to attach the PTU200MIK to the
pole.
Certain meteorological standards
define the altitude for the pressure
measurement. As the transmitter is
installed into the protective box, the
distance of the pressure transducer
from the bottom of the transmitter box
is 192 ±5 mm.
Open
Locked
USER'S GUIDE_______________________________________________________________________
12 __________________________________________________________________ NOVEMBER 2001
CHAPTER 5
DIMENSIONS in mm (in inches)
Static pressure head on the left side
13.8855353 9.1142232
44.72441136
14.6024371
16.5354420
ø
2
5
1
ø
2
.
3
6
2
2
6
0
6.0447154
22.185564
ø 7.874200
5.748146
CHAPTER 5__________________________________________________ DIMENSIONS IN MM (IN INCHES)
VAISALA _________________________________________________________________________ 13
Static pressure head on the right side
13.8855353
9.1142232
44.6261134
14.6024371
5.748146
16.5354420
ø7.874200
21.0039534
ø
2
51
ø
2
.
3
6
2
2
6
0
6.0447154
www.vaisala.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Vaisala PTU200MIK1 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI