2.
1. Contents CQube Espresso
1. Contents page 2
2. General, Safety regulations, Fact, 3
3. Overview, front 4
3. Overview, mixer system 5
3. Overview components, ingredients canister 6
3. Overview membrane switch, button function front 7
3. Overview user card 8
4. Installation and start-up, Position machine, Fit machine 9
Connection of the hoses for cooling unit with carbonic acid, (base cab.) 9
Connection of carbonic acid tube, (base cabinet) 10
Connections: electricity 10
Connections: water, Start-up of coffee maker 11
Connect: electric cable for cold water
12
Fill ingredients canister 13
5. Operation;
Brewing of espresso in cup, Cold water dispenser 14
Brewing of chocolate in jug 15
6. Cleaning program
Clean brew mechanism 16 - 17
Rinsing the blender bowls 18
Cleaning dispenser valves 19
Flush brew mechanism 20
7. Cleaning every week
Disassemble blender system , Wash parts 21
Re-install blender system 22
8. Cleaning and care
Exterior cleaning when necessary 23
Clean condenser - replacement of carbonic acid tube 23
9. Message shown on display 24
10. PROGRAMMING Activate with card 25
11. Programming Main menu 26
Jug Beverage 27
Clean Machine 28
Counters 29-30
12. Dimension sketch 31
3.
2. General . CQube Espresso
Thank you for choosing a CQube espresso machine. We hope you enjoy it !
- The machine must be connected correctly for your own safety.
Read the user guide before using the machine.
- The guide contains important instructions for proper and safe use.
- Always keep the guide close at hand.
The machine must be disconnected from mains electricity supply before carrying out any maintenance.
All installation work must be carried out by quali ed personnel.
Safety regulations
- The appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning the use of the appliance by a person responsible for their safety
- Children should be supervised to ensure they do not play with the appliance
- The brewer must be connected to the water mains in accordance with any national rules that may apply.
Facts:
Built-in grinder
Filtered water with or Optional
without carbonic acid
Function for selecting jug Chocolate
Options for selecting drink 10 -12
Ingredient canister 2
Cleaning function with smartcard Yes
Electronic temperature control Yes
Adjustable coffee strength Yes
Illumination of cup during brewing Yes
Energy-saving mode Yes
USER CARD Yes
Touch screen Optional
Tank volume Thermoblock for espresso, tank 5 L. for Instant/hotwater
Power supply 230V/2200W+170W
Cold water hook-up ½” external thread
Water puri cation lter lter
Carbonated water 20 litres/hour
Bean container 2.0 kg
Ingredient canister chocolate
Ingredient canister topping
Waste box 150 espresso pucks
Temperatures;
The recommended room temperature when the machine operates 20-23 ° C
(maximum 15 - 35 ° C)
Machine weight:
CQUBE M no base cabinet 42 Kg
Base cabinet 25 Kg
Grinder 6 Kg
Cold water 12 Kg
Cold water + carbonic acid 16 Kg
4.
3. Overview, front. CQube Espresso
Cup shelf
Tap for
water drinks
Drip cover
Drip tray
Display
Pre-selection buttons
Energy-saving mode
Stop
Card reader
Accessories;
Base cabinet with carbonic acid tube and cooler
Dispenser
hot drinks
Menu
Drinks
Bean container
Door Lock
5.
3. Overview inside. CQube Espresso
Grinder
Grinder
dispenser
Brewing-
mechanism
Bean-
container
Ingredients
canister
Bean valve
Chute
ON/OFF
switch
Cleaning
buttons
Mixing bowl
Grounds tray
6.
3. Overview of components, ingredients container. CQube Espresso
Ingredients canister.
Detail; Ingredients; Width Height KG Cups in gram Amount of cups
Canister Beans 160 180 2,0 14 143
Canister Chocolate 67 250 1,5 20 76
Canister Topping 67 250 1,1 9 122
Espresso
maskin
Behållare Topping 160 250 2,9 0,01 291
Behållare Chocolate 67 250 1,5 0,02 76
5. Overview of components, function buttons AC12
7.
3. Overview: Membrane switch function, front CQube Espresso
Buttons function front.
Press the buttons if you want to increase a value or browse through a menu.
Press the button if you want to decrease a value or go back through the menu.
Press the Back button if you want to leave the submenu and go back to
the main menu.
Press the Enter button if you want to enter the menu, change a value or a setting.
Con rm the new setting by pressing the E-button.
Press the STOP button if you want to return to the start menu.
ENERGY SAVING MODE button. Keep the STOP button pressed down
for c. 5 seconds. The display shows; Energy Saving Mode. To return to
normal setting, keep the Stop button pressed down for 5 sec.
ENERGY SAVING MODE, the machine switches off the front display and
decreases the temperature in the water tank to c. 65
°C.
USER CARD
5. Overview of components, function buttons AC12
8.
3. Overview: USER CARD CQube Espresso
USER CARD
Insert the card:
Display will show the Service Menu, Jug Beverage and you can now browse
forwards through the menu.
USER CARD Item number: 1602692.
Is used for cleaning and setting jug beverages.
The user card is supplied by your dealer.
For full menus. See Programming Manual.
Service Menu
Jug Beverage
To use the machine again. Remove the card and keep it in a safe place.
9.
4. Installation and start-up. CQube Espresso
1. Place the machine on a at surface that is impermeable to water.
2. With assembly with a base cabinet; Mount the machine's top cabinet with the M6 x 35 screws
supplied.
Figure 1.
A
M6 x 35
Note: Make sure air is able to circulate freely behind the machine. (minimum 10cm).
Note: Only for installation with cold water function.
A
90°
WATER IN CARBONATED WATER OUT
WATER
Installation of refrigeration unit with carbonic acid,
(base cabinet)
3. Connect the 8mm hoses 3 units. (A) parallel
between the top and base cabinets, hose for
hose, left to left, etc. (See g. 1).
10.
4. Installation and start-up. CQube Espresso
Figure 2.
Connect electricity to top cabineton the machine.
5. Connect the plug to a earthed wall socket
230V 10A.
Note: For the coffee machine: cold water unit without carbonic acid
Start-up refrigeration unit on the coffee machine without carbonic acid.
There is no pressure adjustment pump in this machine.
Follow instructions 1, 2, 6, 7, 8, 9,10,14, 16, 17
Note:
Do not connect the electrical cable from the cold water unit, before the machine has
heated up for c.10 minutes.
4. Connect the carbon dioxide tube to the
gas canister and open the tap, check that the
factory set pressure is c. 3.5bar.
May be adjusted +0.5 -1.0 bar.
Put the carbon dioxide tube in place ( gure 2).
CARBONATED WATER WATER OUT
Connect the water to the top cabinet on the machine.
6. Connect the factory-supplied tube to the cold water feed using a ½” R- connection
piece Make sure no folding or sharp bending occurs when you push the machine back
in place.
If the water pipe is new, ush the system with water rst to remove
copper shavings. These can damage the inlet valve.
The new tube set supplied with the appliance must be used. Old tubes may not
be reused. Connection to a closable valve is recommended.
Min. water pressure; 2 bar (200kPa). Max. water pressure: 8 bar (800kPa).
7. Open the water tap.
8. Open the door and switch on the circuit breaker. See gure.
9. Close the door
10. The display indicates Low Water Level, Press Enter Key
Press the E button
The water tank will now automatically ll with 5 litres of water.
At the same time the espresso system will be ushed with
about 50ml of water.
Place a pitcher under the spout of the Espresso.
The element will not be powered until the water reaches the level sensor.
Set temperature is c. 96º Celsius.
11. Once the water heating is complete
the "Low temp" text will disappear from the display. (The display text will start to rotate).
12. Shut off the machine.
11.
4. Installation and start-up. CQube Espresso
ON
Start-up of coffee machine with built-in refrigeration unit for water
13. Now connect the electricity cable which comes from the bottom
cabinet into the electric socket for the machine (B) in the
top cabinet see gure 3).
14. Switch on the machine again:
and wait until the text in the display starts to rotate.
Note: The fresh-brew machine must be warm before cold water can
be dispensed.
15.
Take a glass and Press on the button for cold water until water is dispensed
in an even ow and the pressure increase pump that is buzzing gives a different
calmer sound (refrigeration-compressor is relatively quite so it should not
usually be heard very much)
Note: If no cold water comes. Restart the machine.
16. Press on the button for carbonated water so that the holder lls and until you
have an even ow of water.
After this the pressure increase pump will only have this quieter noise or be
completely quiet,
17. Wait for c. 10 minutes and the machine is ready to be used.
(This is to ensure that the water is refrigerated).
12.
Figure.3.
B
4. Installation and start-up. CQube Espresso
ON
13.
4. Installation and start-up. CQube Espresso
18. Fill the container.
Fill ingredients into the containers.
Remove the ingredients containers to avoid spilling
in the machine) and ll with ingredients.
19. Fill the bean container with coffee beans.
Lift the lid and ll the bean container with freshly
roasted coffee beans without additives. (e.g. avour
essence and sugar), Open the valve (A) on the
bean container.
20. When placing the ingredients container
Ensure that the ingredients pipes are ( ush) against
the condensation traps. See (A).
A A
14.
Brewing a cup of espresso.
1. Put a cup under the espresso dispenser.
2. The strength of the drink is set to default.
If you would like to increase or decrease the
strength then follow the steps in the
section below, otherwise proceed to Point 3.
Stronger drink; Press + button
alternatively
Weaker drink; Press - button
3. Select drink espresso by pressing on
the button espresso on the menu.
The display shows:”Please wait”, and the cup
light goes on.
4. Wait until the cup light switches off and the text
”Please wait” has disappeared from the display
before removing the cup.
5. Operations. Brewing a cup of espresso, CQube Espresso
Cold water dispenser (with or without carbonic acid).
1. Hold a glass under the dispenser for Water and press on the button
COLD WATER or CARBONATED WATER.
Dispensing cold water
15.
5. Operation. Brewing chocolate in a jug. CQube Espresso
1. Put a jug under the espresso dispenser and fold up the cup shelf.
2. Insert the user card in the card reader(A)
3. The display shows Service Menu, Jug Beverage.
4. Press the E button.
5. Change the number of cups you want to brew in your jug.
(6 cups is the default setting.)
with alternative button.
Brewing is possible for up to 12 cups or down to 1 cup.
6. Press the button for chocolate.
Wait until the cup light switches off and the message "please wait" has
disappeared from the display before removing the jug.
7. Remove the user card.
Note: If no selection is made, remove the user card. To stop press the STOP button.
A
1. Insert the user card in the card reader (A)
2. Move through the menu until the display shows
Service Menu, Clean Machine.
3. Press the E button.
4. Move through the menu until the display shows
Select Cleaning, Clean Brewer.
5. Press the E button.
The display shows; Open Door, Fill Detergent.
6. Open the door. The display shows; Fill Detergent, Close Door.
7. Put a cleaning tablet in brewmechanism. See g. B
8. Close the door. The display shows; Place Jug, Enter To Start.
9. Put a 1 litre container under the coffee dispenser. See g. C
Display shows: ”Preparing Please Wait”.
”Preparing Unit” ”Please Wait”.
16.
Automatic cleaning with brewing mechanism:
Cleaning the brewer mechanism should be done once a week.
6. Cleaning programme; Clean brewing mechanism CQube Espresso
g. B
g. C
A
17.
6. Cleaning programme; Clean the brewing mechanism. CQube Espresso
Continuation:
10. Press E-button to start cleaning.
11. Display indicates: Preparing unit, Please wait.
12. Cleaning Unit, Time Left 60 seconds. The machine counts down from 60 seconds.
13. Display indicates: Cleaning unit, Brewcycles left 3. Machine is now cleaning the system.
14. Close door.
15. Remove user card.
Total cleaning time about 5 minutes.
Note: When the cleaning agent has been added, the process must no be interrupted
but be allowed to run its course.
Remember that the water splashing from the spout is very hot!
Espresso machine cleaning for brewing mechanism Is available from
your dealer:
Product no. 1104171
1. Lift up the cup shelf. Put a container that takes c. 0.5 litres under the dispenser
for espresso
2. Insert the user card in the card reader (A)
3. Move through the menu until the display shows Service Menu, Clean Machine.
4. Press the E button.
5. Move through the menu until the display shows Select Cleaning, Clean Mixer.
6. Press the E button.
7. The machine will no clean the blender bowls for c. 5 seconds.
Repeat the cleaning procedures 2-3 times.
8. Remove the user card.
18.
6. Cleaning programme; Rinsing the blender bowls CQube Espresso
Automatic rinsing of the blender bowls, at least once a day.
Cleaning means rinsing with water and rotating the whisk motor.
A
Cleaning of dispenser valves
1. Lift up the cup shelf. Put a container under both the Espresso and Water dispensers.
2. Insert the user card in the card reader (A)
3. Move through the menu until the display shows Service Menu, Clean Machine.
4. Press the E button.
5. Move through the menu until the display shows Select Cleaning, Clean Valves.
6. Press the E button.
7. Dispenser valves will not start to open and close with 3 pulses/second for
a max of 6 seconds. Repeat the procedure 2 - 3 times.
8. Remove the user card.
19.
6. Cleaning programme; Dispenser valves CQube Espresso
Automatic cleaning of dispenser valves:
Cleaning entails that the valves "knock" off any lime scale and other particles
that may get stuck in the cylinders and ushing them with water.
A
20.
6. Cleaning programme; Flush brew mechanism ESP CQube Espresso
Flush brew mechanism with water if necessary.
Flush brew mechanism.
1. Lift up the cup shelf. Put a container under the Espresso dispenser.
2. Insert the user card in the card reader (A).
3. Move through the menu until the display shows Service Menu, Clean Machine.
4. Press the E button.
5. Move through the menu until the display shows Select Cleaning, Rinse Brewer ESP.
6. Press the E button.
7. Brew mechanism will now be ushed with water.
8. Remove the card.
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Crem International cqube espresso User manual

Category
Coffee makers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI