Vmac 1901142 Installation guide

  • I've reviewed the provided document which outlines the installation instructions for the Blowdown Solenoid. The instructions emphasize the importance of vertical mounting and proper orientation to ensure effective drainage and prevent operational issues as described in that document. I am ready to answer your questions regarding this device and its installation.
  • Why should the blowdown solenoid be mounted vertically?
    What size bolt should be used to mount the blowdown solenoid?
    What does the correct orientation of the blowdown solenoid ensure?
Blowdown Solenoid Installation
Mount the blowdown solenoid vertically so that any residual moisture can be
drained and prevent buildup and blockages inside the solenoid valve. Residual
moisture can lead to premature wear on the valve and failure to depressurize
the system.
Locate the blowdown solenoid in a suitable location that provides easy access to it. Use a 5/16”
or M8 bolt with the hole provided in the bracket to mount the blowdown solenoid. Ensure the
blowdown solenoid is orientated as shown in Figure 1 below. This orientation allows the
solenoid to drain any residual moisture that may have entered during the compressor
shutdown and pressure release cycle. Residual moisture can reduce the life of the solenoid or
cause a blockage resulting in malfunction of the pressure release cycle on shutdown.
Figure 1 - Blowdown Solenoid Orientation
Document #: 1901142
Changes and Revisions
Revision
Revision Details
Revised by
Checked by
Implemented
Eng.
Mech.
A
ECN-20-022: Development Release
NDB
PID
SRD
BDJ
AWM
27 JAN 2020
5/16” or M8 bolt
/