FPI Energy U35 User manual

Category
Fireplaces
Type
User manual

This manual is also suitable for

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-528a
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury, property damage, or loss
of life. Refer to this manual. For assistance or additional
information consult an authorized installer, service agency
or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
03/04/08
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
U35 Gas Insert
Owners & Installation Manual
MODELS: U35-NG1 Natural Gas U35-LP1 Propane
2 U35 FPI Direct Vent Gas Insert
FPI GAS FIREPLACE INSERT
TO THE NEW OWNER
Congratulations! You are the owner of a state-of-the-art Gas Insert by FPI.
The U35 Gas Insert has been designed to provide you with all the warmth and charm of a replace,
at the ick of a switch. The U35-NG1 and U35-LP1 have been approved by Warnock Hersey for
both safety and ef ciency. As it also bears our own mark, it promises to provide you with economy,
comfort and security for many trouble free years to follow. Please take a moment now to acquaint
yourself with these instructions and the many features of your FPI Fireplace.
3
U35 FPI Direct Vent Gas Insert
TABLE OF CONTENTS
FPI GAS FIREPLACE INSERT
OPERATING INSTRUCTIONS
First Fire ......................................................................20
Operating Instructions .................................................20
Lighting Procedure ......................................................20
Shutdown Procedure ...................................................20
Final Check..................................................................20
Copy of Lighting Instruction Plate ................................21
Automatic Convection Fan Operation..........................21
Normal Operating Sounds Of Gas Appliances ............21
MAINTENANCE
Maintenance Instructions.............................................22
General Vent ...............................................................22
Maintenance ................................................................22
Log Replacement ........................................................22
Glass Gasket ...............................................................22
Steel or Gold Trim........................................................22
Door Glass ..................................................................23
Fan Maintenance .........................................................23
Removing Valve ...........................................................24
Installing Valve .............................................................25
PARTS LIST
Main Assembly ............................................................26
Burner & Log Assembly ...............................................27
Flush Door And Bay Front Assembly ..........................28
Faceplates, Trims, And Hearths ..................................29
WARRANTY
Warranty ....................................................................31
SAFETY LABEL
Serial No. Decal ...........................................................4
REQUIREMENTS
MA Code - CO Detector
(for state of Massachusetts only)...................................5
INSTALLATION
Important Message ......................................................6
For Your Safety ..............................................................6
Gas Pressure Testing ....................................................6
Speci cations ................................................................6
Installation Into A Solid Fuel Burning
Fireplace Or Factory Built Fireplace ..............................6
Before You Start ............................................................6
Installation Checklist ......................................................7
Materials Required ........................................................7
Minimum Fireplace Dimensions ....................................7
Minimum Clearances To Combustibles .........................8
Venting...........................................................................9
Flue Liner Installation ....................................................9
Gas Connection ............................................................9
Gas Insert Aeration System .........................................10
Gas Pipe Pressure Testing ..........................................10
Optional Brick Panel ....................................................10
Log Installation ............................................................ 11
Faceplate & Trim Installation ....................................... 11
Standard Flush Door ...................................................12
Optional Flush Trim .....................................................12
Flush Louvers ..............................................................12
Optional Bay Door .......................................................13
Optional Bay Trim ........................................................13
Bay Louvers.................................................................13
Double Screen Doors .................................................13
The Kensington Front Installation ................................14
Full Screen Doors ........................................................16
Wiring Diagrams ..........................................................18
Optional Remote Control ............................................19
Optional Wall Thermostat ...........................................19
4 U35 FPI Direct Vent Gas Insert
SAFETY LABEL
This is a copy of the labels that accompany each
U35 Gas Insert. We have printed a copy of the
contents here for your review. The safety label
is located on a plate inside the base of the unit
visible when the bottom louver is opened.
NOTE: FPI units are constantly being
improved. Check the label on the unit and
if there is a difference, the label on the unit
is the correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
5
U35 FPI Direct Vent Gas Insert
REQUIREMENTS
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
MA Code - CO Detector
(for the State of Massachusetts only)
6 U35 FPI Direct Vent Gas Insert
IMPORTANT MESSAGE
The FPI Gas Insert must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual rst.
Consult the building authority having jurisdiction
to determine the need for a permit prior to starting
the installation.
NOTE: Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/or
property damage. Failure to follow these
instructions may also void your re insurance
and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combustion.
Always provide adequate combustion and
ventilation air. Follow instructions and information
in CAN/CGA B149 (in Canada) or the National
Fuel Gas Code ANSI Z223.1 (in the USA),
regarding requirements for combustion and
ventilation air.
GAS PRESSURE
TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut off valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than
1/2 psig. (3.45 kPa).
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
Gas Input Capacity:
Natural Gas 35,000 Btu/h
Propane 35,000 Btu/h
Min. Input (Fan Off)
Natural Gas 17,500 Btu/h
Propane 17,500 Btu/h
Max. Output
Fan On Fan Off
Natural Gas 26,800 Btu/h 26,300 Btu/h
Propane 27,500 Btu/h 27,000 Btu/h
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to
4,500' (0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 127 CFM.
Log Set: Ceramic bre, 3 per set.
Vent System: 3" co-linear aluminum ex.
INSTALLATION
The ef ciency rating of the appliance is a
product thermal ef ciency rating determined
under continuous operating conditions and
was determined independent of any installed
system.
INSTALLATION
INTO A SOLID FUEL
BURNING FIREPLACE
OR FACTORY BUILT
FIREPLACE
The U35 Gas Inserts have been tested and
approved to be vented into any masonry
fireplace or approved solid fuel burning
factory built replace that will allow the insert
to physically t into the rebox. Refer to the
"Minimum Fireplace Dimensions" section for
minimum replace clearances.
If the factory built replace* height is too low
for your Insert, you may remove the smoke
baf e plate and damper from the factory
built replace as long as these items are
saved and are reinstalled in the event that
the Insert is removed. NOTE: Any alterations
made to the listed solid fuel burning factory
built replace may void the listing of the
replace.
*Check with your local inspector before
commencing with this installation.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
General Safety Information
1) The appliance installation must conform
with local codes or in the absence of
local codes, with CAN/CGA B149 (in
Canada) or the National Fuel Gas Code
ANSI Z223.1 in the U.S.A. This appliance
should be installed by a quali ed gas tter
technician only.
2) Installation and repair should be done by
a quali ed service person.
3) The appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint
from carpeting, bedding material, animal
hair, etc. It is imperative that control
compartments, burners and circulating
air passageways of the appliance be kept
clean.
4) See general construction and assembly
instructions. This appliance may only be
installed in a vented, noncombustible
replace.
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) Always connect this insert to a vent system
venting to the outside of the building
envelope. Never vent to another room or
inside a building. Make sure that the vent
is properly sized and is of adequate height
to provide the proper draft.
7) Inspect the venting system annually for
blockage and any signs of deterioration.
8) Any glass removed for servicing must be
replaced prior to operating the appliance.
9) WARNING: Failure to position the parts
in accordance with the diagrams in
this manual or failure to use only parts
speci cally approved with this appliance
may result in property damage or personal
injury.
10) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
replace.
11) Due to high temperatures, the appliance
should be located out of high traf c areas and
away from furniture and draperies. Children
and adults should be alerted to the hazards
of high surface temperatures, especially
the replace glass and gold trims, and
should stay away to avoid burns or clothing
ignition. Young children should be carefully
supervised when they are in the same room
as the appliance. Clothing or other ammable
material should not be placed on or near the
appliance.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
Installer must mechanically attach the supplied
label to the inside of the rebox of the replace
into which the gas replace insert is installed.
"WARNING: This replace has been converted
for use with a gas replace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the replace re-approved by the authority
having jurisdiction."
7
U35 FPI Direct Vent Gas Insert
9) Final check: Before leaving this unit with
the customer, the installer must ensure
that the appliance is ring correctly. This
includes:
a) Clocking the appliance to ensure the
correct ring rate.
b) Adjusting the primary air, if required,
to ensure that the ame does not
carbon. Refer to the "Gas Insert
Aeration System" section.
c) Ensuring that the appliance is venting
correctly.
MATERIALS
REQUIRED
No electrical power supply is required for the gas
control to operate. A 120 Volt AC power cord is
hooked up to the fan. Plug the 3 wire cord into
a suitable receptacle. Do not cut the ground
terminal off under any circumstances. When
connected with 120 volts, the appliance must
be electrically grounded in accordance with
local codes, current version of the Canadian
Electrical Code CSA C22.1 (in Canada) or in
the absence of local codes, with the National
Electrical Code ANSI/NFPA 70.
NOTE: This unit is equipped with a heat
sensor thermodisc which will prevent the
blower from operating until the unit reaches
the correct temperature.
INSTALLATION
INSTALLATION
CHECKLIST
Before installing vent system ensure that the
damper plate is open and secure to prevent the
damper plate from falling down and crushing
the liner.
The FPI Gas Insert is installed as listed
below.
1) Locate insert, refer to the following
sections:
a) Installation Into a Solid Fuel Burning
Fireplace or Factory Built Fireplace
b) Minimum Fireplace Dimensions
c) Minimum Clearnces to Combustibles
d) Venting
2) Make the gas connection. Refer to the "Gas
Connection" section.
3) Install the 3" ue liner to the sliding connector
plate. Refer to the "Flue Liner Installation"
section.
4) Slide the unit half way into the replace.
5) Pull the vent connector plate through the
tapered brackets and fasten to the front
plate. Refer to the "Flue Liner Installation"
section.
6) Slide the unit fully into the replace.
7) Test gas pressure. Refer to the "Gas Pipe
Pressure Testing" section. Check aeration
system. Refer to the "Gas Insert Aeration
System" section.
8) Install the standard and optional features.
Refer to the following sections where
applicable:
a. Log Installation
b. Faceplate & Trim Installation
c. Standard Flush Door
d. Flush Trim
e. Flush Louvers
f. Bay Door
g. Bay Trim
h. Bay Louvers
i. Double Screen Doors
j. The Kensington Front
k. Full Screen Doors
l. Remote Control
m. Wall Thermostat.
MINIMUM FIREPLACE
DIMENSIONS
The minimum replace clearances & dimensions
for the FPI gas replace are shown in the
following diagrams:
WARNING:
Electrical Grounding Instructions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.
A
B
D
E
C
Max Lentil
Bar Depth
A
Height
B
Depth
C
Width
(rear)
D
Width
(front)
E
Regency
Countour
Faceplate
9" 25" 17" 25" 32-1/4"
Regency
Molded
Faceplate
10" 26-3/4" 18" 25" 34-1/2"
Palace
Front
10" 26-3/4" 18" 25" 34-1/2"
8 U35 FPI Direct Vent Gas Insert
MINIMUM CLEARANCES TO COMBUSTIBLES
From Unit
Sides A 8" / 203 mm
Ceiling B 34" / 834 mm
From Standard Surround 31-1/8" x 44-1/8" (791mm x 1121mm)
Sides D 1-15/16" / 49 mm
Ceiling E 28-7/8" / 733 mm
Max. Mantel Depth G 12" / 305 mm
Min. Alcove Width K 48" / 1220 mm
Max. Alcove Depth L 36" / 915 mm
* No Hearth Required
REGENCY BAY & FLUSH
COMBUSTIBLE MANTEL CLEARANCES
KENSINGTON FRONT
COMBUSTIBLE MANTEL CLEARANCES
Mantel can be installed anywhere in shaded area or higher using the above scale.
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
Because of the extreme heat this insert emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in the above diagrams.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible
board.
INSTALLATION
9
U35 FPI Direct Vent Gas Insert
GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work
with gas piping may make the
necessary gas connections to
this appliance.
1) If the appliance is to be installed into an
existing chimney system, thoroughly clean
the masonry or factory built replace.
2) The appliance is provided with an opening on
the left hand side of the control compartment.
A 3/8" NPT gas supply pipe must be brought
near this inlet hole.
In areas of consistently high winds, we
recommend using the Simpson Dura-Vent
System (923GK adapter and 991 high-wind
cap).
The Air Intake pipe must be attached to the inlet
air collar of the termination cap.
INSTALLATION
3) Locate the center point where the vent
will pass through the chimney above the
appliance. Move the appliance into the
exact location where it is to be installed.
Ensure that the Insert is level.
FLUE LINER
INSTALLATION
1) Cut the ex liner as required.
2) Mark the end of one liner with an "E" to
indicate exhaust.
3) Connect the other end of the above liner to
the exhaust side of the termination adaptor,
seal connection with high temperature
silicone. Secure with gear clamp.
4) Connect the 2nd liner to the inlet side of
the adaptor, seal connection with high
temperature silicone. Secure with gear
clamp.
VENTING
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium ex running
the full length of the chimney. The ue length
must be a minimum length of 8 ' (2.44m) and
a maximum of 35' (10.7m). See chart below
for minimum distances from roof. Periodically
check that the vent is unrestricted.
Masonry chimneys may take various contours
which the exible liner will accommodate.
However, keep the exible liner as straight
as possible, avoid unnecessary bending.
Part # Description
948-305 3" Flex - 35 ft.
946-529 Co-linear DV Vertical
Termination Cap
Alternate Approved Caps
980 Vertical Termination Cap
991 High Wind Cap
923GK 3" Co-linear Adaptor with
ashing
5) Install ashing.
6) Insert both liners into chimney, passing
through the damper opening.
7) Install termination cap.
8) Connect the marked end of the liner to the
exhaust collar of the vent connector plate
marked with an "E", seal connection with
high temperature silicone. Secure with gear
clamp.
9) Connect the 2nd liner to the intake collar
marked with an "I", seal connection with
high temperature silicone. Secure with gear
clamp.
NOTE: 1) Final gas connection should be
made after unit is in place to avoid
damage to line when pushing the unit
into position.
2) Mill-pac may be used instead of
high temperature silicone and screws
may be used instead of gear clamps
at connections of liner to inlet and vent
collars.
10 U35 FPI Direct Vent Gas Insert
OPTIONAL
BRICK PANEL
1) Unwrap the brick pattern panels from the
protective wrapping.
2) Remove the glass front if it is already
installed (see manual).
3) Put the rear brick panel at against the back
of the unit.
4) Before installing the side brick panels,
loosen the screws for the brick tabs enough
so that you can slide the brick tabs on to the
screws easily but that the tabs are secure.
For the location of the side brick tab screws
see diagram 1.
Diagram 1
Diagram 2
GAS PIPE
PRESSURE TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
(3.45 kPa). Disconnect piping from valve at
pressures over 1/2 psig.
The manifold pressure is controlled by a
regulator built into the gas control, and should
be checked at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1) Make sure the valve is in the "OFF"
position.
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8"
wide at screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits speci ed on the safety
label.
6) When nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
at screwdriver. Note: Screw should be
snug, but do not over tighten.
INSTALLATION
GAS INSERT
AERATION SYSTEM
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue ame or close for a yellower
ame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.
Minimum Air Shutter Opening:
1/8" Natural Gas
1/4" Propane
SIT Valve Description
1) Gas on/off knob
2) Manual high/low adjustment
3) Pilot Adjustment
4) Thermocouple Connection - option
5) Outlet Pressure Tap
6) Inlet Pressure Tap
7) Pilot Outlet
8) Main Gas Outlet
9) Alternative TC Connection Point
CAUTION: Carbon will be produced if air
shutter is closed too much.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Note: Aeration Adjustment should only
be performed by an authorized FPI
Installer at the time of installation or
service.
5) Remove the brick tabs and slide the side
brick panels into position. Install the brick
tabs. See diagrams 1 and 2.
11
U35 FPI Direct Vent Gas Insert
Rear View: Trim Assembly
Diagram 2
Rear View: Faceplate Assembly
Diagram 1
FACEPLATE & TRIM
INSTALLATION
1) Lay the faceplate panels at, face down on
something soft so they don't scratch.
2) Take the top faceplate and align the holes in
it with the holes in the side panels. Using the
screws provided, attach from the top of the
panel (the holes in the top panel are slightly
larger than the holes in the side panel to
facilitate easier installation). Diagram 1.
Hint: Don't tighten the screws down
completely at this point, continue on with
steps 3 and 4 and do a trial t to the unit.
Make any necessary adjustments and when it
ts properly then tighten down the screws.
3) Using the connectors provided, join the left
side trim (with the ON/OFF switch) to the top
trim. Diagram 2. Connect the right side trim
to the top trim.
4) Place the trim on the assembled faceplate
panels, aligning the wire connections from
the switches with the notch on the left side
panel.
5) Connect the fan switch wires by taking the
black and red wires with the male ends (in
the grey harness) and connect them with
the wire connectors from the fan speed
control.
6) Connect the ON/OFF switch wires by taking
the black and red wires with the female ends
and connect them to the ON/OFF switch.
7) Tuck the wires into the faceplate to keep
them away from the insert using the clip
provided. Attach the clip to the rear of the
faceplate to ensure that the wires do not
touch the side of the unit.
Diagram 3.
8) The power cord should be run behind the
faceplate panel.
INSTALLATION
LOG INSTALLATION
WARNING: Dangerous operating
conditions may occur if these logs
are not positioned in their correct
certi ed locations. Read the following
instructions carefully and refer to the
attached diagram.
1) Remove the logs from the box and carefully
unwrap them. The logs are fragile, handle
with care. Do not force into position.
2) Sprinkle the vermiculite and ember on the
sides of the rebox base.
3) Place the rear log on the rear log support at
the back of the unit with the at side of the
log facing the back of the unit. Gently push
the log down onto the pins.
4) Place the front logs in the unit, aligning
the holes on the underside of the logs with
the log support pins in the front of the unit.
Carefully push the logs down onto the pins.
(Hint: Install the front right side rst.)
6) Install the door and louvers
.
5) Separate platinum embers (supplied with
packaged manual) and spread loosely in
front of and inbetween the front logs and
in front of the rear log on the burner. Avoid
stacking platinum embers.
12 U35 FPI Direct Vent Gas Insert
Diagram 4
Diagram 5
Diagram 3
INSTALLATION
9) Attach the brass trim to the faceplate by
drilling a 1/8" hole through into the faceplate
using the hole in the trim as a guide. Fasten
the trim to the faceplate panels using the
plated screws. Diagram 4.
10) Attach the faceplate panels to the insert
body using the 4 remaining black screws.
Diagram 5.
11) Push the Regency logo plate into the
two holes in the bottom left corner of the
faceplate. See Diagram 4.
Diagram 6
Use the hook to pull the spring out until you
can put the hook into the slot on the bottom
door bracket. Repeat for 2nd spring. See
diagram 8.
Diagram 8
Diagram 7
STANDARD
FLUSH DOOR
The standard ush door comes with a black
frame. To install the frame, simply hook the top
door ange onto the top of the unit and swing
the door towards the unit, diagram 6. Be careful
that the glass gasket does not roll up; there must
be a gap between
the gasket and the
door lip to ensure
that the door sits
securely on the
unit. Diagram 7.
To remove the ush door, reverse the above
steps.
NOTE: The chain must rest on TOP of the gas
inlet pipe never under it.
OPTIONAL FLUSH TRIM
Attach 2 round magnets to the back of the top
trim piece and the other 2 to the bottom trim
piece, then attach trim to the top and bottom
of Flush door.
FLUSH LOUVERS
2) Install the Spring Hinges on the left and right
side of the bottom of the Firebox using 2
screws per hinge.
3) Place the Bottom Louver near the hinge. Flip
hinge over the Bottom Louver and secure
using 3 screws.
Bottom Louver
Hinge
Location
1) The top louver is held in place by friction t,
if the louver needs to be adjusted; bend the
bracket out as shown in the diagram.
13
U35 FPI Direct Vent Gas Insert
INSTALLATION
BAY LOUVERS
1) Install top louver by sliding the two bracket
clips into the brackets located on top of the
bay door. See below. The tted louver leaves
a small gap between faceplate bottom and
louver top.
Diagram 4
OPTIONAL BAY DOOR
The Bay louvers MUST be used
with the Bay glass option.
The optional Bay door is an overlay on the
ush front. The standard ush door and glass
must remain on the unit. Hook the top of the bay
door over the ush door ange and swing the
bottom against the bottom ange of the ush
door. Press down on the Bay Bottom bracket
and push in until it clips behind the bottom of
the ush front.
Diagram 3
OPTIONAL BAY TRIM
Attach 4 supplied magnets each to the back
of the top and bottom trim pieces, and attach
trim to the top and bottom of Bay door. See
diagrams 3 and 4.
Removing Bay Door
To remove only the Bay Door - use a screwdriver
to unclip the Bay Bottom bracket from the ush
door and then swing up and unhook from the
top ush door ange.
To remove the Bay Door & the Flush Front
together, pull the hook from the slot in the
bottom door bracket under the unit (see Standard
Flush Door instructions above). Then pull the
Bay Door and Flush door out and lift off of the
ange at the top of the unit.
Note: If any maintenance etc. must be done
in the rebox, rst remove the Bay
louvers and door.
2) Install bottom louver by sliding the two
bracket clips into the brackets located
underneath the bay door. Secure with 1
screw into each Bottom Louver Mounting
Bracket as per diagram below. Use the
bottom hole in the bracket.
DOUBLE SCREEN
DOORS
1) Pull out the top louver.
2) Center the screen door and hook over the
ush door.
Clip locations
Clip installed on right side.
3) Open the screen door(s) and secure the
screen door to the ush door front with 2
clips on the bottom left and right side.
3) Slide the valve extension knobs onto the valve
knobs. Match each extension knob with the
corresponding valve knob. Extension knobs
are for Bay Front installations only.
14 U35 FPI Direct Vent Gas Insert
THE KENSINGTON FRONT INSTALLATION
INSTALLATION
IMPORTANT: Please use the gloves provided when handling the Kensington Front to avoid ngerprints.
3) Slide the Tabs on the Blanking Plate into the slots located on
Front and secure using 2 screws.
Kensington
Front
Blanking Plate Tabs
1) Place the Kensington Front up against the unit, but do not secure.
Make the following wire connections:
Connect the fan switch wires by taking the black and red wires with
the male ends (in the grey harness) and connect them with the wire
connectors from the fan speed control.
Connect the ON/OFF switch wires by taking the black and red wires
with the female ends and connect them to the ON/OFF switch.
Tuck the wires into the faceplate to keep them away from the insert
using the clip provided. Attach the clip to the rear of the faceplate to
ensure that the wires do not touch the side of the unit.
The power cord should be run behind the faceplate panel.
Kensington
Front
Left Side Shown
2) Mount the Kensington Front onto the rebox by securing in place
using 4 screws, 2 per side.
Screws
Blanking
Plate
Screw Screw
15
U35 FPI Direct Vent Gas Insert
THE KENSINGTON FRONT INSTALLATION
3-Panel Door Installation:2-Panel Door Installation:
Sub-Frame
1) Install the Sub-Frame by hooking the top ange onto the top of the
Glass Door and swing the Sub-Frame towards the unit. Pull out the
hooks which already secure the Glass Door and place them thru the
holes in the bottom of the Sub-Frame to secure both the Glass Door
and Sub-Frame in place together.
Glass Door
Hook
Sub-Frame
2) Mount the 2-panel Door Frame to the ange on Sub-Frame, ensuring
to line up holes. Secure using the 6 screws provided.
3) Hook the Left Side Screen Door to the Door Frame by placing the
door hinges (top & bottom) over the pins on the Door Frame. Repeat
for Right Side Screen Door.
Note: It will be easier to put the Screen Door in place by starting with
the bottom hinge.
Left Side Door
Pin on Door Frame
Note: If you nd that the Left or Right Side Screen Door is lower then
the other, use the spacer provided to help align the Doors.
The spacer is to be placed over the bottom pin before installing the
Screen Door.
Sub-Frame
1) Install the Sub-Frame by hooking the top ange onto the top of the
Glass Door and swing the Sub-Frame towards the unit. Pull out the
hooks which already secure the Glass Door and place them thru the
holes in the bottom of the Sub-Frame to secure both the Glass Door
and Sub-Frame in place together.
Glass Door
Hook
Sub-Frame
2) Mount the 3-panel Screen Door / Frame Assembly to the ange on
Sub-Frame, ensuring to line-up holes. Secure using the 4 screws
provided.
INSTALLATION
16 U35 FPI Direct Vent Gas Insert
FULL SCREEN DOORS
INSTALLATION
1) Hold the full screen faceplate up against the unit in order to make
the following wire connections.
Pull the ON/OFF connector wires thru the box and connect them to
the switch.
Connect the fan switch wires with the wire connectors from the fan
speed control. Place clips over wires and tuck into side trim.
2) Lift the unit up slightly and push down on the corners of the Bottom
Trim Bracket and slide under unit.
3) Completely secure faceplate to the unit by securing 4 screws to the
Left and Right Side Trim.
Bottom Trim
Bracket
Push in Corners
4) Secure the Top Frame by sliding it on the screws at the top of the
full screen door. It is held in place by magnets.
Top Frame
Screw
17
U35 FPI Direct Vent Gas Insert
INSTALLATION
6) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and
secure with 3 screws each.
Bottom Frame
Hinge Location
5) Install Spring Hinges to the Left and Right Side of the bottom of the
rebox using 2 screws per hinge.
7) Install the Left and Right Side Screen Doors by placing over top of
the hinges on the faceplate.
Hold the door at a 45 degree angle to avoid scratching the
faceplate.
Hinge
Screen Door
8) Close screen doors.
18 U35 FPI Direct Vent Gas Insert
WIRING DIAGRAMS
INSTALLATION
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous operation.
This heater does not require a 120V A.C. supply
for operation. However, a 120V A.C. power
supply is needed for the fan/blower operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug.
Caution: Ensure that the
wires do not touch any
hot surfaces and are
away from sharp edges.
For NATURAL GAS Units and Units NOT Equipped with DC Spark Boxes
19
U35 FPI Direct Vent Gas Insert
Use the FPI Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the replace to
that location. Use Thermostat Wire Table.
2) Connect the wires as per the wiring diagrams
below.
CAUTION
Do not connect the millivolt
remote control wires
to the 120V wires.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
OPTIONAL REMOTE CONTROL
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired,
follow the wiring diagram below. Note: the wires
are connected to the "TH" on the gas valve. Use
the table below to determine the maximum wire
length. FPI offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
It is recommended that the thermostat be
installed on an interior wall.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
INSTALLATION
For PROPANE Units and Units Equipped with DC Spark Boxes
20 U35 FPI Direct Vent Gas Insert
OPERATING INSTRUCTIONS
IMPORTANT: Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
1) Turn burner OFF using "ON/OFF" switch.
2) Turn gas control knob so indicator points
to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.
3) Turn gas control knob counterclockwise
so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the ignitor button several times until the
pilot lights. After approximately one minute,
release the gas control knob. The pilot ame
should continue to burn. If the pilot does
not remain lit, repeat operation allowing a
longer period before releasing gas control
knob.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON"
position.
5) Use the wall switch, thermostat or remote
control to turn on the unit.
6) Rotate the ame height regulator to adjust
the ame height higher or lower.
SHUTDOWN
PROCEDURE
1) Use the wall switch, thermostat or remote
control to turn off the main burner.
2) Turn the main gas control clockwise to the
"OFF" position to turn off the pilot.
3) Turn off all electric power to appliance if
service is to be performed.
FIRST FIRE
The rst re in your insert is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you
burn your replace for at least four (4) hours
the rst time you use it with the fan on. When
rst operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
The glass panel may require cleaning
after the unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and
will disappear in a few minutes as
the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels, if used, are
installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
LIGHTING
PROCEDURE
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size Max. Length
Thermostat Wire Table
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is ring
correctly. This includes:
1) Clocking the appliance to ensure the
correct ring rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to ensure
that the ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior facia
is not the responsibility of
During the rst few res, a white lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the lm will bake on and
become very dif cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
IMPORTANT
To ignite or reignite the pilot,
you must rst release the ten-
sion springs below the door.
NOTE: For all propane units and units
equipped with electric spark boxes,
see "Copy of Lighting Plate Instruc-
tions" section for more details.
Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not be operated with the tension springs
unattached.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

FPI Energy U35 User manual

Category
Fireplaces
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI