AtlasScientific EZO Complete-TMP User guide

  • Hello! I've reviewed the user guide for the Atlas Scientific EZO Complete-TMP temperature meter. This device is capable of reading temperatures between -126.000 °C to 1254 °C, supporting various probe types, and has a IP62 rating and single point calibration. It seems like a versatile tool for precise temperature measurements, and I'm ready to answer your questions about it.
  • What is the temperature range supported by the EZO Complete-TMP?
    What type of probes are compatible with the EZO Complete-TMP?
    Is the EZO Complete-TMP protected against water?
    Can the EZO-Complete readings be influenced by other sensors?
    What is the reading time of EZO Complete-TMP?
Single pointCalibration
1 reading /sec
Temp reading time
Any type & brand
PT-100 or PT-1000
Supported probes
EZO Complete-TMP
USB Temperature meter
Users Guide
Range -126.000 °C to 1254 °C
+/– (0.1 + 0.0017 x °C)
Accuracy
Reads Temperature
AtlasScientific
PWR
RX
TX
V 1.0
Released 7/23
This is an evolving document, check back for updates.
Written by Jordan Press
Designed by Noah Press
PATENT PROTECTED
Interference free
The EZO complete readings are unaffected by other sensors in the same water.
Ingress protection – IP62
The EZO Complete-TMP is dust proof and resistant to splashing water.
Two areas of concern are the USB connector and the probe connector.
USB connector
Probe connector
AtlasScientific
PWR
RX
TX
AtlasScientific
PWR
RX
TX
AtlasScientific
PWR
RX
TX
AtlasScientific
PWR
RX
TX
AtlasScientific
PWR
RX
TX
AtlasScientific
PWR
RX
TX
75.7mm (2.9”)
54.3mm
(2.1”)
AtlasScientific
PWR
RX
TX
2Copyright © Atlas Scientific LLC
The SMA connector is part of your probe; Nothing should be in contact with this part.
A connector short can occur if water enters the SMA connector. A connector short will
cause the temperature readings to pin to -1023, or the probe will respond slowly to changes
in temperature. A connector short is reversible and will not damage the EZO-Complete.
However, frequent shorts will eventually damage the temperature probe.
Ingress protection – IP62
An electrical short can occur if water enters the USB connector. A USB short could permanently
damage the EZO-Complete. A USB short is not covered under warranty.
Do not use this
as a mounting point!
3Copyright © Atlas Scientific LLC
Setup
AtlasScientific
PWR
RX
TX
Female BNC
to Male SMA
connector
C-FB-MS
Male SMA
to Male SMA
connector
C-MS-MS
Temperature probe
with BNC Connector
Micro Temperature probe
with SMA Connector
Tinned leads with the SMA
to terminal block connector
Correct Correct Correct Correct
Temperature probe
with SMA Connector
Atlas
Scientific
PRB GND
Click here to download
4Copyright © Atlas Scientific LLC
Once you have installed the AtlasDesktop monitoring software, you can begin monitoring
and logging your readings.
Setup complete
AtlasScientific
PWR
RX
TX
Temperature
26.22
Setup
5Copyright © Atlas Scientific LLC
Always watch the readings throughout the calibration process.
Issue calibration commands once the readings have stabilized.
Issuing a calibration command before the readings stabilize will result in drifting readings.
96.4
98.2
99.5
99.5
99.5
Cal,100
*OK
100
100
100
81.7
86.9
Cal,100
*OK
100.9
102.3
109.1
113.3
115.9
121.2
96.4
98.2
99.5
99.5
99.5
Cal,100
*OK
100
100
100
81.7
86.9
Cal,100
*OK
100.9
102.3
109.1
113.3
115.9
121.2
Never do a blind calibration!
Best practices for calibration
6Copyright © Atlas Scientific LLC
Calibration procedure
Within the AtlasDesktop monitoring software, click on the "gear" icon.
Follow the on-screen calibration steps.
Advanced setup
The EZO-Complete-TMP readings can be linked to other EZO-Complete sensors to provide
temperature compensation to the other sensors readings.
Entering the conductivity setup page, you can link the readings from your EZO-Complete
temperature sensor to your conductivity readings, this will give you temperature compensated
conductivity readings.
The connected EZO-complete-TMP is the device with address 129.
If multiple temperature sensors are connected, multiple address will be listed.
(The temperature sensor address is listed in the temp sensor setup page)
We setup an EZO-complete monitoring system to read conductivity and temperature.
Example
8Copyright © Atlas Scientific LLC
/