Altronix ALTV615DC8ULCB User manual

  • Hello! I am an AI chatbot trained to assist you with the Altronix ALTV615DC8ULCB User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Overview:
Altronix ALTV615DC8ULCB CCTV Power Supply is designed with eight (8) individually PTC protected power-limited, Class 2 Rated outputs for powering
CCTV cameras and other video accessories. It provides 6VDC-15VDC distributed via eight (8) PTC protected outputs with a total of up to 4A continuous
supply current.
Specifications:
Agency Listings:
UL Listed for Commercial Closed-Circuit Television Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio, Video and Similar Equipment.
Input:
Input 115VAC, 50/60 Hz, 0.9A.
Output:
6VDC-15VDC adjustable output.
Eight (8) individually PTC protected, auto-resettable
Class 2 Rated power-limited outputs.
4A total continuous supply current.
Filtered and electronically regulated outputs.
PTC Ratings:
Output PTCs are rated at 2.5A/250VAC (Fig. 1).
Visual Indicators:
AC input and DC output LED indicators.
Additional Features:
Spare fuses included.
Unit maintains camera synchronization.
Ease of installation saves time and eliminates costly labor.
Enclosure Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).
Note: For a model with factory installed 3-wire line cord
add suffix “3”, i.e. ALTV615DC8ULCB3, and disregard
paragraph 2 in Installation Instructions.
Installation Instructions:
1. Mount ALTV615DC8ULCB in desired location.
2. Connect green lead to earth ground. Connect AC (115VAC, 50/60 Hz) to the black and white flying leads of the transformer (Fig. 1).
Use knockout adjacent to the transformer. 0.25” spacing must be provided between AC input wiring and all other circuits.
3. Adjust output voltage using trimpot on the board prior to connecting CCTV devices (Fig. 1a).
4. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1P-8P] are positive (+) and terminals marked [1N-8N] are negative.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the output voltage.
5. Connect each DC CCTV cameras to the terminal pairs marked [1P-1N] through [8P-8N] on PD8CB board (Fig. 1), carefully observing correct polarity.
6. Green LED will illuminate when when unit is powered.
7. Upon completion of the wiring secure enclosure door with screws (supplied).
Keep power-limited circuits (outputs 1 through 8) away from non power-limited. 0.25” space must be provided.
Use separate knockouts.
Caution: Equipment to be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to NEC and all local codes.
Door
XFMR
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1 2 3 4 5 6 7 8
D1
INPUT
R1 LED
F1 F2 F3 F4 F5 F6 F7 F8
+ DC -
- BAT +
AC AC
DC
AC
Voltage
Adjustment
Use separate
knockouts for
power-limited
circuits.
Class 2 Not Wet/
Class 3 Wet
Wire
Strap
(from
Enclosure
to Door)
Black Lead
White Lead Green Lead
115VAC input
50/60 Hz,
0.9A
non power-
limited
Fig. 1
Fig. 1a
Door
XFMR
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1 2 3 4 5 6 7 8
D1
INPUT
R1
LED
F1 F2 F3 F4 F5 F6 F7 F8
+ DC -
- BAT +
AC AC
DC
AC
Voltage
Adjustment
Use separate
knockouts for
power-limited
circuits.
Class 2 Not Wet/
Class 3 Wet
Wire
Strap
(from
Enclosure
to Door)
Black Lead
White Lead Green Lead
115VAC input
50/60 Hz,
0.9A
non power-
limited
ALTV615DC8ULCB
CCTV Camera and Accessory Power Supply
Terminal Identification:
AL400ULB - Power Supply Board
Terminal Legend Function/Description
AC/AC Low voltage AC input (24VAC 100VA). Altronix part #T24130.
+ DC --- 6VDC-15VDC @ 4A total continuous output.
PD8ULCB - Distribution Module
Terminal Legend Function/Description
1P - 8P Positive DC output, Class 2, power-limited.
1N - 8N Negative DC output, Class 2, power-limited.
Enclosure Dimensions (H x W x D approximate):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
1.40”
(35.6mm)
1.40”
(35.6mm)
1.40”
(35.6mm)
4.85” (123.2mm) 4.85” (123.2mm)
3.25” (82.6mm)
0.75”
(19.1mm)
0.75”
(19.1mm)
11.0” (279.4mm)
12.5” (317.5mm)
1.20”
(30.5mm)
1.20”
(30.5mm)
0.9375” (23.8mm)
0.9375” (23.8mm)
5.10” (129.5mm)
1.40”
(35.6mm)
5.10” (129.5mm)
6.5625” (166.7mm)
3.25” (82.6mm)3.25” (82.6mm)
3.25” (82.6mm)
10.5” (266.7mm)
1.0”
(25.4mm)
1.0”
(25.4mm)
1.0” (25.4mm)
13.0” (330.2mm)
5.10” (129.5mm)
1.20”
(30.5mm)
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIALTV615DC8ULCB Rev. 042806 K16U MEMBER
/