Balboa Hand Held Jet For Gunite Operating instructions

Type
Operating instructions

This manual is also suitable for

HAND HELD JET FOR GUNITE INSTRUCTIONS
Turn off circulation pump. 1.
Remove the therapy option from the Gunite Micro’ssage or Converta’ssage jet. 2.
Remove the nozzle from inside the jet, by turning it counter-clockwise. (A 9/16” nut driver or a 9/16” 3.
socket on a ratchet extension will allow easy removal of the nozzle from the Gunite Micro’ssage or
Converta’ssage.)
The Gunite adapter (#1) is sent with the quick disconnect (#7) unglued. (This allows you to shorten or 4.
lengthen the adapter to your installation). After modifications in length to the adapter (if any) glue the
quick disconnect (#7) onto the adapter (#1). Allow to dry.
Twist lock the Hand Held Gunite Adapter (#1) into the opening from which the nozzle was removed. 5.
Connect the Hand Held quick disconnect (#8) to the adapter quick disconnect (#7). 6.
The hole on the float (#2) must be above the water level to draw air. 7.
Start the circulation pump. 8.
Squeeze the trigger (#4) to start the Hand Held Jet (#3) and release the trigger (#4) to stop it. 9.
TO CHANGE THERAPY OPTION IN HAND HELD JET:
Insert cage and eyeball (#5) (or flowpath, #6) into Hand Held Jet (#3) by pressing firmly to snap into place.
CONTACT YOUR RETAILER OR SPA MANUFACTURER FOR OTHER THERAPY OPTIONS.
88-4049, Rev. A June 1, 2009
#1 50-4403T Hand Held Jet Adapter for Gunite
#2 36-5317 Float
#3 36-5312 Hand Held Jet
#4 36-5314 Trigger
#5 30-4826 Cage & Eyeball
#6 36-4811 Flowpath
#7 30-5708F Adapter Quick Disconnect
#8 30-5708M Hand Held Quick Disconnect