Graco 334143E, EcoQuip Vapor Abrasive Blast System Owner's manual

Type
Owner's manual
Operation,Repair,andParts
EcoQuip EcoQuip
EcoQuipVapor Vapor
VaporAbrasive Abrasive
Abrasive
Blast Blast
BlastSystem System
System334143E
EN
Vapor Vapor
Vaporabrasive abrasive
abrasiveblast blast
blastsystem. system.
system.For For
Forprofessional professional
professionaluse use
useonly. only.
only.
Important Important
ImportantSafety Safety
SafetyInstructions Instructions
Instructions
Readallwarningsandinstructionsinthismanual.Savethese
instructions.
125 psi (8.6 bar, 0.86 MPa) Maximum
Working Pressure
See page 3 for Model information.
PROVENQUALITY.LEADINGTECHNOLOGY.
Contents Contents
Contents
Models...............................................................3
RelatedManuals................................................3
Warnings...........................................................4
Notes.................................................................7
SystemComponentIdentication.........................8
EQ300SandEQ600S..................................8
DataTrakControls........................................9
PressureReliefProcedure..................................10
Grounding(ATEXSystemsonly).........................10
Operation...........................................................11
ImportantNote.............................................11
ChecklistBeforeStarting..............................11
LiftingtheSystem........................................11
ConnectingtheBlastHoseandAir
Hose..............................................12
SettingUptheEquipment.............................13
BlastingTips................................................17
UsingtheWashFeature...............................19
RellingthePotwithAbrasive.......................20
ShuttingDown.............................................21
WinterizingtheEquipment............................23
Troubleshooting..................................................24
TroubleshootingExamples...........................28
Repair................................................................30
RepairingtheMainAirRegulator..................30
FlushingtheDiaphragmValve......................31
RepairingtheDiaphragmValve.....................32
CleaningtheAuto-VentValve.......................33
ReplacingtheDataTrakBattery....................34
ReplacingtheDataTrakFuse.......................35
Parts..................................................................36
EQ300SandEQ600S..................................36
Enclosure....................................................38
PressurePot................................................40
BlastHoses.................................................41
HoseSchematic.................................................42
VaporAbrasiveBlastSystemsand
Accessories..........................................43
EcoQuipSystemCongurator.......................43
ModelSeries...............................................44
BlastHoseswithControlHose/Cables...........45
BlastHoseswithoutControl
Hose/Cables..................................45
BlastControlHoses/Cables..........................46
Nozzles.......................................................46
OtherAccessories........................................46
CommonSpareParts...................................47
Dimensions........................................................48
TechnicalSpecications......................................49
GracoExtendedWarrantyforEcoQuip™
Components.........................................50
2
334143E
Models
Models Models
Models
Model Model
ModelDescription Description
DescriptionApprovals Approvals
Approvals
EQ300SEcoQuip300VaporBlastSystem
EQ600SEcoQuip600VaporBlastSystem
EQ30XSEcoQuip300VaporBlastsystemATEXApproved
II 2G c ia IIA T3 X
EQ60XSEcoQuip600VaporBlastSystemATEXApproved
II 2G c ia IIA T3 X
Related Related
RelatedManuals Manuals
Manuals
Manual Manual
ManualNumber Number
NumberProduct Product
Product
313840DataTrak
333397Pump
335035AirInletKit
334142EQ100M
334666EQ200T,EQ400T
334667EQ300C,EQ600C
334143E 3
Warnings
Warnings Warnings
Warnings
Thefollowingwarningsareforthesetup,use,grounding,maintenance,andrepairofthisequipment.The
exclamationpointsymbolalertsyoutoageneralwarningandthehazardsymbolsrefertoprocedure-specic
risks.Whenthesesymbolsappearinthebodyofthismanualoronwarninglabels,referbacktothese
Warnings.Product-specichazardsymbolsandwarningsnotcoveredinthissectionmayappearthroughout
thebodyofthismanualwhereapplicable.
WARNING WARNING
WARNING
SPECIAL SPECIAL
SPECIALCONDITIONS CONDITIONS
CONDITIONSFOR FOR
FORSAFE SAFE
SAFEUSE USE
USE
Groundallequipmentintheworkarea.SeeGrounding Grounding
GroundingInstructions Instructions
Instructions.
Alllabelandmarkingmaterialmustbecleanedwithadampcloth(orequivalent).
DUST DUST
DUSTAND AND
ANDDEBRIS DEBRIS
DEBRISHAZARD HAZARD
HAZARD
Useofthisequipmentcanresultinthereleaseofpotentiallyharmfuldustortoxicsubstances
fromtheabrasivebeingused,thecoatingsbeingremoved,andthebaseobjectbeingblasted.
Foruseonlybysophisticatedusersfamiliarwithapplicablegovernmentalsafetyandindustrial
hygieneregulators.
Useequipmentonlyinawell-ventilatedarea.
Wearaproperlyt-testedandgovernmentapprovedrespiratorsuitableforthedustconditions.
Followlocalordinancesand/orregulationsfordisposaloftoxicsubstancesanddebris.
4
334143E
Warnings
WARNING WARNING
WARNING
EQUIPMENT EQUIPMENT
EQUIPMENTMISUSE MISUSE
MISUSEHAZARD HAZARD
HAZARD
Misusecancausedeathorseriousinjury.
Donotoperatetheunitwhenfatiguedorundertheinuenceofdrugsoralcohol.
Donotexceedthemaximumworkingpressureortemperatureratingofthelowestrated
systemcomponent.SeeTechnical Technical
TechnicalData Data
Datainallequipmentmanuals.
Donotusethisequipmentwithouthoserestraintsandcouplerpinsinstalledonallairand
blasthosecouplings.
Donotblastunstableobjects.Thehighamountofuidowfromthenozzlecanpotentially
moveheavyobjects.
Donotexceedloadratingoflifteyes.
Donotoperateequipmentonorstandonanunstablesupport.Keepeffectivefootingand
balanceatalltimes.
Useuidsandsolventsthatarecompatiblewithequipmentwettedparts.SeeTechnicalData
inallequipmentmanuals.Readuidandsolventmanufacturer’swarnings.Forcomplete
informationaboutyourmaterial,requestMSDSfromdistributororretailer.
Donotleavetheworkareawhileequipmentisenergizedorunderpressure.
TurnoffallequipmentandfollowthePressure Pressure
PressureRelief Relief
ReliefProcedure Procedure
Procedurewhenequipmentisnotinuse.
Checkequipmentdaily.Repairorreplacewornordamagedpartsimmediatelywithgenuine
manufacturer’sreplacementpartsonly.
Donotalterormodifyequipment.Alterationsormodicationsmayvoidagencyapprovals
andcreatesafetyhazards.
Makesureallequipmentisratedandapprovedfortheenvironmentinwhichyouareusingit.
Useequipmentonlyforitsintendedpurpose.Callyourdistributorforinformation.
Routehosesandcablesawayfromtrafcareas,sharpedges,movingparts,andhotsurfaces.
Donotkinkoroverbendhosesorusehosestopullequipment.
Keepchildrenandanimalsawayfromworkarea.
Complywithallapplicablesafetyregulations.
BURN BURN
BURNHAZARD HAZARD
HAZARD
Equipmentsurfacesanduidthatisheatedcanbecomeveryhotduringoperation.Toavoid
severeburns:
Donottouchhotuidorequipment.
FIRE FIRE
FIREAND AND
ANDEXPLOSION EXPLOSION
EXPLOSIONHAZARD HAZARD
HAZARD
Flammablefumes,suchassolvent,inwork work
workarea area
areacanigniteorexplode.Tohelppreventre
andexplosion:
Useequipmentonlyinwellventilatedarea.
Abrasivematerialexitingblastnozzlecangeneratesparks.Whenammableliquidsareused
neartheblastnozzleorforushingorcleaning,keeptheblastnozzleatleast20feet(6
meters)awayfromexplosivevapors.
Keepworkareafreeofdebris,includingsolvent,ragsandgasoline.
Keepaworkingreextinguisherintheworkarea.
334143E 5
Warnings
WARNING WARNING
WARNING
PERSONAL PERSONAL
PERSONALPROTECTIVE PROTECTIVE
PROTECTIVEEQUIPMENT EQUIPMENT
EQUIPMENT
Wearappropriateprotectiveequipmentwhenintheworkareatohelppreventseriousinjury,
includingeyeinjury,hearingloss,inhalationoftoxicfumes,andburns.Protectiveequipment
includesbutisnotlimitedto:
Protectiveeyewearandhearingprotection
Protectiveclothing,shoes,andgloves
Properlyt-testedandgovernmentapprovedrespiratorsuitableforthedustconditions
RECOIL RECOIL
RECOILHAZARD HAZARD
HAZARD
Blastnozzlemayrecoilwhentriggered.Ifyouarenotstandingsecurely,youcouldfalland
beseriouslyinjured.
6 334143E
Notes
Notes Notes
Notes
334143E
7
SystemComponentIdentication
System System
SystemComponent Component
ComponentIdentication Identication
Identication
EQ300S EQ300S
EQ300Sand and
andEQ600S EQ600S
EQ600S
8 334143E
SystemComponentIdentication
Key: Key:
Key:
AFrame
BBlastControlSwitch
B2BlastNozzle
CBlastHose
EPot
FPop-upPin
GWaterTank
HWaterTankLid
JPotDumpValve
KAutoVentValve
LBlastCheckValve
MAbrasiveBallValve
NInletBallValve
PControlBox
QEmergencyStop
RBlastAirRegulator
SAbrasiveMeteringValve
Key: Key:
Key:
TPotPressureRegulator
UPotPressureGauge
VBlastAirPressureGauge
WSelectorValve
XRinseBallValve
YAirSupplyConnection
ZBlastConnection
ZAPneumaticControlConnection
ZBElectricControlConnection(non-ATEX
systemsonly)
ZCSupplyAirPressureGauge
ZDDataTrak(seeDataTrakControls,page9)
ZEAccessoryExtensionhose
ZFAbrasiveMaterial
ZGFillPort
ZHGroundWireandClamp(ATEXSystems
only)
DataTrak DataTrak
DataTrakControls Controls
Controls
8800000
83000
9
Key: Key:
Key:
RKResetKeyResultsinfaults.Pressand
holdforthreesecondstoclearthebatch
totalizer.
CRCycle/Rate
BTBatchTotalizer
GTGrandTotalizer
334143E 9
PressureReliefProcedure
Pressure Pressure
PressureRelief Relief
ReliefProcedure Procedure
Procedure
FollowthePressureReliefProcedure
wheneveryouseethissymbol.
Thisequipmentstayspressurizeduntilpressure
ismanuallyrelieved.Tohelppreventserious
injuryfrompressurizeduid,suchassplashing
uid,followthePressureReliefProcedurewhen
instructed.
1.Turnthepotpressureregulator(PR)off.
2.Closetheabrasiveballvalve.
3.Turnthecompressoroff.Closethecompressor
supplyairvalve.
4.Engagetheblastcontrolswitchtorelieve
pressureinthesystem.
5.Verifythatthesupplyairpressuregaugereads0
psi.Thendisconnecttheairinlethosefromthe
system.
6.Turntheselectorvalve(SL)toFILL.
7.Openthedumpvalve.
8.Verifythatthepotpressuregauge(PG)displays
zeropressure.
Grounding Grounding
Grounding(ATEX (ATEX
(ATEX
Systems Systems
Systemsonly) only)
only)
Theequipmentmustbegroundedtoreducethe
riskofstaticsparking.Staticsparkingcancause
fumestoigniteorexplode.Groundingprovidesan
escapewirefortheelectriccurrent.
Systems: Systems:
Systems:Usesuppliedgroundwireandclamp
(237686).
Air Air
Airand and
anduid uid
uidhoses: hoses:
hoses:UseonlygenuineGracoATEX
rated,conductivehoseswithamaximumof150ft
(45m)combinedhoselengthtoensuregrounding
continuity.Checktheelectricalresistanceofthe
hoses.Ifthetotalresistancetogroundexceeds29
megaohms,replacethehoseimmediately.
Air Air
Aircompressor: compressor:
compressor:followmanufacturer’s
recommendations.
10 334143E
Operation
Operation Operation
Operation
Important Important
ImportantNote Note
Note
Topreventfreezing,thisequipmentisshippedfrom
thefactorywithbluewindshieldwasheruidinside
thesystem.Itisnotnecessarytodrainbefore
using.Disposeoftheuidinaccordancewithlocal
regulations.
Checklist Checklist
ChecklistBefore Before
BeforeStarting Starting
Starting
Checkthecompressedairsupplyaccordingtoits
operatormanual.Makesuretheairbeingsupplied
iscleanandrelativelyfreeofmoistureandoil
topreventwatercontaminationoftheaircontrol
components.
Makesureairdeliveryvalvesareclosedbeforethe
airsupplycompressorisstarted.
Makesureallrequiredhoserestraintsandcoupler
pinsareinworkingconditionandproperlyinstalled.
Makesuretheequipmentissituatedonlevel
ground.Failuretokeeptheunitonlevelground
willmakeitdifcultorimpossibletopurgeallofthe
airfromthepressurevessel.
Makesuretheequipmentisproperlysupportedon
asurfacethatcanholditstotalweight.Theweight
ofallpersonnel,thematerialbeingblasted,and
anyabrasivebeingstoredmustalsobeconsidered
(seeTechnicalSpecications,page49).
Makesurethewatertankwillremainfullysupplied
withcleanwatertoavoidanypossibilityofthe
pumprunningdryduringblasting.
Makesurethatthepotiscleanandfreeofany
internaldebris.
Makesuretousethecorrecttypeofblastcontrol.
Anelectricorpneumaticblastcontrolswitchcan
beusedwithhoselengthslessthan150ft(45m).
Blastingwith150ft(45m)ormoreofblasthose
requirestheuseofanelectricblastcontrolswitch.
Makesuretheblasthoseislaidoutasstraightas
possiblebetweentheequipmentandtheworksite
(acoiledblasthosewilluncoilunderpressure).
NOTICE NOTICE
NOTICE
Sharpbendsintheblasthosecouldcausethe
abrasivetowearthroughthehoseandcause
prematurefailureofthehose.
Makesuretherubbergasketineachhosecoupler
isinworkingcondition.
Lifting Lifting
Liftingthe the
theSystem System
System
Liftthesystemwithaliftapparatusrated
appropriatelyfortheweightofthesystem(see
TechnicalSpecications,page49).
Donotliftthesystembytheliftringsonthepot.
Liftthesystemusingallfourcornerlifteyeson
theframe.
334143E
11
Operation
Connecting Connecting
Connectingthe the
theBlast Blast
BlastHose Hose
Hoseand and
andAir Air
Air
Hose Hose
Hose
1.EQ30XS EQ30XS
EQ30XSand and
andEQ60XS EQ60XS
EQ60XSonly: only:
only:Connectthe
groundingcabletotheexternalgroundstud(ZH)
ontheenclosure,thenconnecttheclamptoa
trueearthground.
2.Alwayspurgetheairsupplyhose15–20seconds
beforeconnectingtheairsupplyhosefromthe
compressor(oron-sitecompressedairsource)
tothepanel.Makesurealldebrisisclearedfrom
thehose.
3.Connectanappropriatelysizedair
supplyhosetotheairinlet.See
TechnicalSpecications,page49.
NOTE: NOTE:
NOTE:Makesuretoproperlyinstallhose
restraintsandcouplerpinstothequick-coupler
andtheairline.Iftheholesonthequick-coupler
donotalign,thereissomethingwrongandthe
twocouplersarenotcompatible.DO DO
DONOT NOT
NOTTURN TURN
TURN
ON ON
ONTHE THE
THEAIR AIR
AIR.Seekhelptogetthesituation
resolved.
4.Opentheairsupplyvalve(125psi,8.6Bar,0.86
MPamaximum).Ifnecessary,usearegulatorin
thesupplyairlinetomeetthesespecications.
OFF
START
RUN
NOTE: NOTE:
NOTE:Makesuretheairsupplymeets
theappropriate appropriate
appropriateair air
airow ow
owrequirements. requirements.
requirements.See
TechnicalSpecications,page49.
5.Connecttheblasthose,hoserestraints,control
hoses,andcouplerpins.
NOTE: NOTE:
NOTE:Ifyouareusinganelectricblastcontrol,
checkalloftheelectricalconnectionsfromthe
paneltotheblastcontrol.
NOTICE NOTICE
NOTICE
Makesurenoelectricalconnectionswill
beexposedtowater.Exposuretowater
couldcauseashortcircuitanddamagethe
equipment.
12
334143E
Operation
Setting Setting
SettingUp Up
Upthe the
theEquipment Equipment
Equipment
1.Disconnecttheabrasivehoseatthecamand
groovewiththeabrasiveballvalveclosed.
NOTE: NOTE:
NOTE:Ifthepotcontainswaterandabrasive
(especiallyunderpressure),releasingthecam
andgroovewiththeballvalveopenwillcausean
unintentionalreleaseofabrasive.
2.Flushwaterthroughthepotandoutofthe
disconnectedabrasiveballvalvebeforellingthe
potwithwaterandabrasive.
3.Reconnecttheabrasivehose.
4.Disconnectthepumpinlethoseandushthe
watertanktoremoveanyremainingdebris.
Reconnectthepumpinlethose.
5.Fillthewatertankonlywithfreshwater,then
opentheinletballvalve.
6.Closetherinse,dump,andabrasiveballvalves.
334143E 13
Operation
7.TurntheselectorvalvetoRINSE.
8.DisengagetheEmergencyStop.
NOTE: NOTE:
NOTE:Thewaterpumpwillnotworkunlessthe
EmergencyStopisdisengaged.
9.Alignthepop-uphandlewiththepinslot,and
thenrmlypushandturnthehandle90°afterthe
pinisbelowthebracketslot.Properengagement
ofthepinwillholdthepop-updownuntilitis
released.
10.Add10gallons(30liters)offreshwaterto
thepot.Wearappropriatepersonalprotective
equipment,includinganappropriatelyt-tested
governmentapprovedrespiratorsuitableforthe
dustconditions.Addabrasivematerial(minimum
fourbags,maximumten50lb(23kg)bagsof
high-massabrasive,oreight50lb(23kg)bags
oflowmassabrasive).
12
10 gal
(30 L)
200-500 lb
(90-227 kg)
11.Useagardenhoseortherinsehosetowashthe
abrasiveintothepotandclearanyabrasivefrom
thepop-upandgasket.
12.Whenthewaterlevelreachesthepop-upgasket,
rotatethehandletoreleasethepop-uppin.
NOTE: NOTE:
NOTE:Makesurethepop-upgasketiscleanof
alldebris.
14
334143E
Operation
13.TurntheselectorvalvetoFILL.
NOTE: NOTE:
NOTE:Thewaterpumpshouldbegincycling.If
not,openthepotpressureregulatorenoughto
causethepumptorunat60cpm.
NOTE: NOTE:
NOTE:Theautovent/purgevalvewillallowall
oftheairtrappedinthetopofthepottovent.
Whenairstopsventing,thepotpressuregauge
willstarttoregisterpressure.
14.Waitforpotpressuretoincrease.
NOTE: NOTE:
NOTE:Itcantakeuptoseveralminutesforthe
pottopressurize.
ti24824a
NOTE: NOTE:
NOTE:Thepop-upcannotbepusheddown
unlessallofthepressureinthepotisreleased
byopeningthedumpvalve.
15.Setthepotpressure30psi(2.0Bar,0.2MPa)
higherthantheintendedblastpressure.Open
andclosethedumpvalveafterthepumpstalls.
Relievepotpressureto40psi(2.7Bar,0.27
MPa)beforeclosingthedumpvalve.Repeat
untilpotpressureisconsistent.
16.TurntheselectorvalvetoWASH.
17.Settheblastairpressure30psi(2.0Bar,0.2
MPa)lowerthanthepotpressurewhileblasting.
NOTE: NOTE:
NOTE:Inordertoadjusttheblastpressure,
theblastcontrolswitchmustbeengaged.For
theinitialsetting,leavetheabrasiveballvalve
closed.
NOTE: NOTE:
NOTE:Engageandreleasetheblastcontrol
switcheachtimetheblastregulatorisadjusted.
18.TurntheselectorvalvetoBLAST.
19.Opentheabrasiveballvalve.
NOTE: NOTE:
NOTE:Makesurethepotpressurereturnstothe
initialsetting(itwillnotreturntotheinitialsetting
iftheabrasivemeteringvalveisclosed).
334143E 15
Operation
20.Engagetheblastcontrolswitchandbegin
blasting.
NOTE: NOTE:
NOTE:Youmayhavetowait1–2minutesforthe
abrasivematerialtoreachthenozzle.
NOTE: NOTE:
NOTE:Potpressureandblastpressureshould
equalizeduringblasting.Onlysetpotpressure
withtheabrasiveballvalveclosed.Neveradjust
potpressurewhileblasting.
21.Slowlyadjusttheabrasivemetervalvewhilethe
abrasiveisblastingfromthenozzle.Typical
adjustmentrangesfrom1/8to1/4turnopen.
NOTE: NOTE:
NOTE:TheDataTrakcanbeusedtoassistin
settingthepumpcyclerate.Optimalabrasive
mediaconsumptiontypicallyoccurswiththe
cycleratesetat7–10cyclesperminute.
8800000
83000
9
NOTE: NOTE:
NOTE:Useapieceoftestmaterialsimilarto
whatyouwillbeblasting.
NOTE: NOTE:
NOTE:Alwaysstartasgentlyaspossibleand
thenincreasetheblastforceasnecessaryto
cleanwithoutdoinganydamagetothesubstrate.
Whenproperlyset,thepumpshouldcycle7-10
timesperminute.Highproductionrateusers
mayneedtoincreasecyclerateabove10cycles
perminute.
NOTE: NOTE:
NOTE:Closetheabrasiveballvalvewhenever
youstopblastingformorethan20-30minutes.
Thiswillhelptoextendtheservicelifeofthe
diaphragmvalve.
16 334143E
Operation
Blasting Blasting
BlastingTips Tips
Tips
Whenrstlearningtheeffectsoftheblaster,geta
betterunderstandingoftheresultsbystartingata
shallowangle(closertothanto90°)andkeep
thenozzleapproximately16in.(40cm)fromthe
application.Observetheresults,thenreducethe
distance,steepentheangle,andadjusttheblast
regulator.
Astheblastpressureisincreased,slowlyadjustthe
abrasivemeteringvalveandwatchtheDataTrak
toachieve7-10pumpcyclesperminute.See
DataTrakControls,page9.
NOTE: NOTE:
NOTE:Theheavierandsmallertheabrasiveparticle
(i.e.80-grit),themoreaggressivetheresults.
Blasting Blasting
Blastingon on
onHigher Higher
HigherSurfaces Surfaces
Surfaces
Whenblastingonasurfacehigherthanthe
equipment,makesurethatthereisalengthofblast
hoseonthegroundequalto10-20%oftheheight.
Thehoseonthegroundpreventsunspentabrasive
inthehosefromback-llingtheinternalplumbingof
thepanel.
Forexample:Whenblasting50feet(15m)straight
up,useatleast10feet(3m)ofblasthoseonthe
groundbeforetheblasthosegoesuptotheblasting
height.
334143E
17
Operation
Abrasive Abrasive
AbrasiveMetering Metering
MeteringValve Valve
ValveSettings Settings
Settings
Thereisnoxedformulaforwhatworksbestineachapplication.Theinformationbelowworksbestforthe
majorityofthetime.Fromthisinitialsetting,adjustmentscanbemadeupordowntogetthefastestremoval
rateswithoutdamagetothesurface.
Normalsettingsare:110psi(7.5Bar,0.75MPa)initialpotsetting,lessthan1/2turnopenmeteringvalve,
blastingpressureat80psi(5.5Bar,0.55MPa).Forapplicationsrequiringhigherperformance,use
high-performanceabrasive(theheaviestmass@80grit)suchasGarnet,andthehighestpressuresthe
systemcansupport.Theinitialpotpressureshouldalwaysbe30psi(2.0Bar,0.2MPa)abovetheintended
blastpressure.
Graduallymakeadjustmentstomeetthespecicrequirementsforeachapplication.Makeadjustments(see
DataTrakControls,page9)toachieve7-10cyclesperminutetobethemostefcient(cutatthefastestrate
whileusingtheleastamountofabrasive).Blastingpressurescanrangebetween30-120psimax(2.0Bar,
0.2MPa8.2Bar,0.82MPa).
Unlikeconventionalsandblasting,higherpressuresdonotnecessarilymeanbettercleaning.Nozzledistance
andtheangletothesurfacehasaneffectonperformance,asdoestheblastpressure.Choiceofabrasive
alsohasagreateffect.High-performanceabrasiveproducesthebestperformanceandcansaveenough
timetomakeupthedifferenceincost.
NOTE: NOTE:
NOTE:Blastingwith150ft(45m)ormoreblasthoserequirestheuseofanelectricblastcontrol.
Grit Grit
GritSize Size
SizeBlast Blast
Blast
Pressure Pressure
Pressure
Abrasive Abrasive
Abrasive
Metering Metering
MeteringValve Valve
Valve
Blast Blast
BlastAngle Angle
AngleNotes Notes
Notes
General General
General40/70crushed
glass
60-80psi(4.1Bar,
0.41MPa-5.5Bar,
0.55MPa)
10cyclesper
minute
35°-65°None
Wood Wood
Wood80(usingalow
massabrasive
likecrushedglass
orwalnut)
40-50psi(2.7Bar,
0.27MPa-3.4Bar,
0.34MPa)
8cyclesper
minute
15°-30°Donotwash,asit
mayraisethewood
grain.Brushoff
excessabrasiveafter
thewooddries.
Steel Steel
Steel60–80(using
ahigh-mass
abrasivelike
Garnet)
100-120psi(6.8Bar,
0.68MPa-8.2Bar,
0.82MPa)
10–12cyclesper
minute
45°-65˚None
Fiberglass Fiberglass
Fiberglass40-70lowmass45-65psi(3.1Bar,
0.31MPa-4.4Bar,
0.44MPa)
8cyclesper
minute
35°-45˚None
NOTE: NOTE:
NOTE:Adjustmentinblastpressurerequiresanadjustmentoftheabrasivemeteringvalve.
18 334143E
Operation
Using Using
Usingthe the
theWash Wash
WashFeature Feature
Feature
Thewashfeaturecausesair-drivenwater(without
abrasive)torinseareasthathavealreadybeen
blastedwithabrasive.Itisalsoaconvenientfeature
forushingabrasivefromtheblasthose.
NOTICE NOTICE
NOTICE
Therewillalwaysbesomeresidualabrasivein
theblasthose.Neverusethewashfeatureon
anysurfaceotherthanwhereyouhaveblasted,or
intendtoblast.Itwillaffect/dullthesurface.
NOTICE NOTICE
NOTICE
Donotusethewashfeatureonwoodthathas
beenblasted.Itcoulddamagethewoodandcause
thegraintorise.Waitforthewoodtodryandthen
useabroom,brush,orvacuumtoremoveany
residualabrasive.
1.Closetheabrasiveballvalve.
2.TurntheselectorvalvetoWASH.
3.Blast12minutesuntiltheabrasiveiscleared
fromthehose.
4.Theequipmentisnowreadytowashany
previouslyblastedsurfaces.
334143E 19
Operation
Relling Relling
Rellingthe the
thePot Pot
Potwith with
withAbrasive Abrasive
Abrasive
1.Closetheabrasiveballvalve.
2.TurntheselectorvalvetoRINSE.
3.Openthedumpvalveslowlytorelievethewater
pressureinthepot.
NOTE: NOTE:
NOTE:Bepreparedtocapturethewaterthat
willbedrainedfromthepot.Alldisposalsmust
complywithnational,state,andlocalregulations.
4.Afterallofthepressureinthepothasbeen
relieved,engagethepop-uppinbycompressing
thespringandturningthehandle90°toholdthe
pop-upintheopenposition.
5.Addtheabrasive(minimumfourbags,maximum
ten50lb(23kg)bagsofhigh-massabrasive
oreight50lb(23kg)bagsoflow-mass
abrasive)andcontinuetheproceduresfrom
SettingUptheEquipment,page13.
NOTE: NOTE:
NOTE:Morewatermayneedtobedrainedfrom
thepottoallowadditionalabrasivetobeadded.
20 334143E
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Graco 334143E, EcoQuip Vapor Abrasive Blast System Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI