Kohler GM81385-KP2 User manual

Type
User manual

Kohler GM81385-KP2 is a Wireless Load Control Module Accessory Kit that easily integrates with generators that are equipped with either the RDC2 or DC2 controller. It offers a convenient way to manage and monitor power usage, providing real-time insights into the operation of your generator. This kit allows you to remotely control individual circuits, ensuring optimal power allocation during outages.

Kohler GM81385-KP2 is a Wireless Load Control Module Accessory Kit that easily integrates with generators that are equipped with either the RDC2 or DC2 controller. It offers a convenient way to manage and monitor power usage, providing real-time insights into the operation of your generator. This kit allows you to remotely control individual circuits, ensuring optimal power allocation during outages.

Residential/Light Commercial Generator Accessories
Kohlerr OnCuer Plus
Generator Management System
OnCue Plus Web Application Status View
OnCue Plus Mobile Device App Views
G6-140 (OnCuer)1/14
Applicable Models
Use OnCue Plus to monitor and control Kohler Residential and
Light Commercial generator sets equipped with the following
controllers:
D RDC2 or DC2 Controller
D RDC or DC Controller
D VSC Controller (6VSG variable-speed DC generator set)
OnCue Plus Features
D Use your computer and/or mobile device to monitor your
Kohler power system from any location in the world with
Internet access.
D OnCue Plus apps for iPhoner,iPadr and Androidt devices
areavailableontheAppStore
SM
and Google Playt.
D Simple connection and setup -- just enter the generator set
serial number, controller password, and activation code once.
Then monitor your power system from your computer and/or
mobile devices.
D Monitor y our complete Kohler power system, including the
generator, RXT automatic transfer switc h*, Load Control
Module (LCM)*, and Programmable Interface Module (PIM)
[.
D Control home automation when the generator set is paired
with a Programmable Interface Module (PIM)
[. Remote
control features:
d Remotely turn appliances, outdoor lighting, storm shutters,
or other electrical equipment on or off.
d The generator does not need to be running in order to use
OnCue Plus for remote control of circuits connected to the
PIM.
D Monitor your home’s power consumption for full power
management control at your finger tips. (LCM required.*
])
D Monitor multiple generator sets. Generator selection panel
lis ts multiple generator systems on one account and allows
easy selection of one system for detailed monitoring and
control.
D View time- and date-stamped event history listing generator
set starting and stopping, faults, and notifications.
D Choose to send generator notifications to selected recipients
by email and/or text message.
D Start and stop generator exercises from your computer or
mobile device.
D Clear faults from a remote location.
D Controller password and generator set serial number protect
against access by unauthorized users.
D All Ethernet communication is fully authenticated and
encrypted for privacy.
Apple, the Apple logo, iPhone and iPad are registered trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark
of Apple Inc.
Android and Google Play are trademarks of Google Inc.
* Model RXT automatic transfer switch and LCM can be used with generator sets equipped with the RDC2 or DC2 controller.
[ PIM can be used with generator sets equipped with the VSC, RDC2, or DC2 controller.
] Patent pending.
Note: Views shown in this document are samples. Actual views may vary based on customer application and OnCue Plus program updates.
G6-140 (OnCuer)1/14
Typical Connections
RDC2 or DC2
Generator Set Controller
Router *
Cable or
DSL
Modem *
* Customer-provided
[ The load shed kit, if equipped, is installed inside the ATS enclosure.
Tablet *
Ethernet cables *
UPS *
(optional)
PC/
laptop *
Kohlerr System
OnCuer Plus
Server on the
Internet
Multiple PCs can
be connected.
ATS
LCM or
Load
Shed
Kit [
PIM
TP-6928
Smart phone*
RDC2/DC2 Controller
Tablet *
Smart phone*
TP-6928
RDC or DC
Controller
Ethernet
Board[
Router *
Cable or
DSL
Modem *
Ethernet cables *
UPS *
(optional)
Remote
PC *
Kohlerr generator set
* Customer-provided. Router and modem may be combined in one box.
[ OnCue kit GM62465-KP1 is required.
RDC/DC Controller
OnCuer Plus
Server on the
Internet
Tablet *
Smart phone*
VSC Generator Set
Controller
Router *
Cable or
DSL
Modem *
* Customer-provided
[ One optional PIM or one communications kit can be installed
Ethernet cables *
UPS *
(optional)
Kohlerr System
Multiple PCs can
be connected.
PIM or
comm. kit [
TP-6928
Battery Bank *
PC/
laptop *
VSC Controller
OnCuer Plus
Server on the
Internet
G6-140 (OnCuer)1/14
View System Operation Data
Generator Set
D Home is running on generator or utility power
D Generator set status: running, standby, shutdown, or off
D Generator power, in kW (LCM required*
[)
D Engine starting battery voltage, VDC
D Generator event history with description, time, and date
D Active fault indication with description, time, and date
D Engine speed, RPM
D Exercise type
D Engine hours
D Last exercise date and time
D Next scheduled exercise date and time
D Exercise Interval
Load Control Module (LCM)[
D View connected loads
D On/Off indicators for each circuit indicate status (powered or
shed)
D Change load labels to identify the connected circuits
D Loads are connected or shed automatic ally based on
generator load
D See G6-120 for more information
Programmable Interface Module (PIM)]
D View relay status
D On/Off indicators show connected circuits
D Change input and output labels to identify connected circuits
D See G6-121 for more information
6VSG Communications Kit
D View input and output status
D On/Off indicators show connected circuits
Remote Control/Home Automation
Generator Set
D Start/stop exercises remotely
D Clear or reset faults remotely
Programmable Interface Module (PIM)]
D Allows remote control of appliances and other electical
devices in your home
D Use your PC or mobile device to turn your lights or
appliances on and off from any location with web access
D The generator does not need to be running in order to use
OnCue Plus for remote control of circuits connected to the
PIM.
System Requirements
D Personal computer (PC) requires an Internet browser with
Adober Flashr player 12 or higher
D Mobile devices require Android t Gingerbread 2.3 or higher
or iOS 4.3 or higher
D Always-on Internet access for the generator (for example,
cable, DSL, or phone line modem connected 24 hours)
D Internet router and network cable for generator connection to
Ethernet
D Uninterruptible power supply (UPS) for modem and router
(optional)
Internet Explorer is a registered trademark of Microsoft Inc.
Adobe Flash is a registered trademark of Adobe Systems Incorporated in
the United States and/or other countries.
Applicable Generator Set Controllers
RDC Controller DC Controller
RDC2 Controller DC2 Controller
VSC Controller
* Patent pending.
[ Model RXT automatic transfer switch and Load Control Module (LCM) can be used with generator sets equipped with the RDC2 or DC2 c ontroller.
] PIM can be used with generator sets equipped with the VSC, RDC2, or DC2 controller.
2014 by Kohler Co. All rights reserved.
DISTRIBUTED BY:
G6-140 (OnCuer)1/14
OnCuer Plus System Kits
D For the RDC2/DC2/VSC controller:
d Activation code decal
d Ethernet connector
d Operation manual
RDC2/DC2 and VSC c ontrollers have built-in Ethernet capability .
D For the RDC/DC controller:
d OnCue Ethernet option board
d Installation instructions
d Operation manual
Ethernet Option Board Specifications
(RDC/DC controller only)
D Environmental specifications:
d Operating temperature: --30 _Cto70_C(--22_F to 158_F)
d Storage temperature: --40_Cto85_C(--40_F to 185_F)
d Humidity: 5--95% non-condensing
D Standard RJ45 jack for network connection
D Standard 10/100 Ethernet
Computer,
Dealer /Service
KOHLERr Light
Commercial Generator
with RDC2 or DC2
Controller
Cell Phone
SMS Text Message
tp6928
KOHLERr Residential
Generator with RDC,
DC, RDC2, or DC2
Controller
KOHLERr Model 6VSG
Generator
OnCue Server on
the Internet
Tablet
Email, Text
Message, App
Smart Phone
Email, Text Message, App
Computer, Customer
Home, Office , Vacation, Travel
OnCue Plus System
Kohler Power Systems
Asia Pacific Headquarters
7 Jurong Pier Road
Singapore 619159
Phone (65)6264-6422, Fax (65)6264-6455
KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-457-4441, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KOHLERPower.com
Availability is subject to change without notice. Kohler Co. reserves the
right to change the design or specifications without notice and without any
obligation or liability whatsoever . Contact your local Kohlerr generator
distributor for availability.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kohler GM81385-KP2 User manual

Type
User manual

Kohler GM81385-KP2 is a Wireless Load Control Module Accessory Kit that easily integrates with generators that are equipped with either the RDC2 or DC2 controller. It offers a convenient way to manage and monitor power usage, providing real-time insights into the operation of your generator. This kit allows you to remotely control individual circuits, ensuring optimal power allocation during outages.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI