- 19 -
G1/G2/G3
(EDS-611/
EDS-619
only)
AMBER
10/100 Mbps link is active.
Blinking
Data is being transmitted at 10/100
Mbps.
10/100 Mbps link is inactive.
GREEN
1000 Mbps link is active.
Blinking
Data is being transmitted at 1000
Mbps.
1000 Mbps link is inactive.
10/100M
AMBER
Data is being transmitted at 10 Mbps.
10 Mbps link is inactive.
Green
Data is being transmitted at 100 Mbps.
100 Mbps link is inactive.
Specifications
Standards IEEE802.3, 802.3u, 802.3x, 802.1D, 802.1w,
802.1Q, 802.1p, 802.1X, 802.3ad, 802.3z
IGMP V1/V2 device, GMRP, GVRP, SNMP
V1/V2c/V3, DHCP Server/Client, BootP, TFTP,
DHCP Option66.67.82, SSH, MODBUS/TCP,
SNMP INFORM, SNTP, SMTP, RARP, RMON
MSTR/HEAD, CPLR/TAIL, 10/100/1000M (GB
port), 10/100M (Module TX/FX port), IEEE 1588
PTP, and IPv6
MIB-II, Ethernet-like MIB, P-BRIDGE MIB,
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON
10/100/1000BaseT(X) auto negotiation speed,
F/H duplex mode, and auto MDI/MDI-X
Optional 100/1000Base SFP modules
PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL,
G1, G2, G3
10/100M for TP port, 100M for Fiber port
Alarm Contact
Two relay outputs with current carrying capacity
of 1 A @ 24 VDC
Two inputs with the same ground, but
electrically isolated from the electronics
• For state “1”: +13 to +30 V
• For state “0”: -30 to +3 V
• Max. input current: 8 mA
12/24/48 VDC, redundant inputs
Note: 24 VDC has been certified by DNV.
Input Current (@12 V) EDS-608: 2.3 A
EDS-611: 2.3 A