Sanyo KHHS2672R User manual

Category
Split-system air conditioners
Type
User manual
System: 26KHHS72R Indoor/Outdoor: KHHS2672R/CH2672R
Wall Mounted Heat Pump with Heater
Power V/PH/Hz 230/208/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
Weight
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
Heating
Total Capacity
HSPF
(A) 15-30 Indoor-Outdoor
(A) 15-30 Indoor-Outdoor
General Data (at 230V)
1
(A) 12.9-17.5
Propeller
18-7/64-1
DC Motor
(RPM) 8 - 800
(W) 1 - 90
15.9
(Pints/H) 7.4
(BTU/H) 23,000 (9,500-23,000)
(BTU/H) 13,520
(BTU/H) 9,480
(Uncrated) 14-9/16 x 49-7/32 x 8-9/32
(W) 2,610/2,610
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffeled
(in.) 3/8”
4.19
Split System Submittal Data
Electric Expansion Valve
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
1 - 15.9
(sq.ft.) 7.26
(lbs.) 44.1 128
(A) 14.0/15.5
(in. O.D. Discharge) 3/8”
(in. O.D. Suction) 5/8”
DC Rotary Inverter
(High) 1765
(A) 13.8
R410A
(in.) H x W x D
(Crated) 18-7/16 x 52-23/32 x 11-3/8
Indoor Outdoor
(cu.ft.) 6.4 13.0
Indoor Outdoor
(lbs.) 59.5 148
(dB-A) 49
Cross Flow
4-1/3, L39 - 1
3 & Auto
(RPM, High) 4 - 1227
(W) 1 - 30
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
(in.) 3/8”
2 - 12.7
(sq.ft.) 2.57
(HI/Med/Lo) 540/460/380
(A) 7.8
(in.) 1-1/4”
(Hi) (dB-A) 45
Flare
165
50 (outdoor lower), 100 (outdoor higher)
(Uncrated) 30-23/32 x 37 x 13-3/8
(Crated) 34-31/32 x 39-31/32 x 16-3/32
10.3
(BTU/H) 27,600 (8,000-27,600)
Print Form
Dimensional Data for 26KHH72R
Dimensions
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive
Wood Dale, IL 60191 USA
www.sanyohvac.com
Heating
Amps
Max. Amps
Power Inputs
Back-up Strip Heater
Outdoor Sounds Rating
Features
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
Power Failure Automatic Restart
Heating/Cooling Automatic Changeover
Self-Diagnosis
Air Filter
Options
Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removeable Remo-con Bracket
Operating Range
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Heating
Maximum 95F DB/71F WB 115F DB
Minimum 67F DB/57F WB 0F DB
-
Available
N/A
N/A
N/A
Available
Available
Built-In
Built-In
Built-In
Washable, Anti-Mold
Microprocessor
LCD Wireless Type, Temp. Sensor Built In
(Horizontal) Manual
24 Hr. Program
IC Thermostat
Built-In
(Vertical) Automatic
(bels) 49
(W) 2,720/2,720
(KW 1.80/1.47
(A) 14.6/16.1
(A) 22.4/23.2
Maximum 80F DB/67F WB 75F DB/65F WB
Minimum -DB/-WB 5F DB
Dimensional Data for 26KHH72R
  • Page 1 1