Nortel Networks NN43021-110 User manual

Category
Servers
Type
User manual
Nortel Communication Server 1000
Communication Server 1000M
and Meridian 1 Large System
Overview
Release: 5.5
Document Revision: 02.05
www.nortel.com
NN43021-110
.
Nortel Communication Server 1000
Release: 5.5
Publication: NN43021-110
Document status: Standard
Document release date: 30 September 2008
Copyright © 2003-2008 Nortel Networks
All Rights Reserved.
Sourced in Canada
LEGAL NOTICE
While the information in this document is believed to be accurate and reliable, except as otherwise expressly
agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF
ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are
subject to change without notice.
Nortel, Nortel (Logo), the Globemark, SL-1, Meridian 1, and Succession are trademarks of Nortel Networks.
All other trademarks are the property of their respective owners.
.
3
.
Contents
New in this Release 5
Other 5
Revision History 5
How to get help 7
Getting help from the Nortel Web site 7
Getting help over the telephone from a Nortel Solutions Center 7
Getting help from a specialist by using an Express Routing Code 7
Getting help through a Nortel distributor or reseller 8
Introduction 9
Subject 9
Applicable systems 9
Intended audience 10
Conventions 10
Related information 11
Product description 13
Contents 13
Introduction 13
System options 15
CS 1000M HGand Meridian 1 Option 51C 15
CS 1000M SGand Meridian 1 PBX 61C CP PIV 18
CS 1000M MGand Meridian 1 PBX 81C CP PIV 21
System modules 24
NT4N41 Core/Network module 24
NT5D21 Core/Network module 26
NT8D35 Network module 27
Fiber Network Fabric 29
NT8D37 Intelligent Peripheral Equipment module 30
Fiber Remote IPE module 31
Carrier Remote IPE 31
System architecture 33
Contents 33
Hardware architecture 34
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
4
Common control complex 35
Network interface 39
Intelligent Peripheral Equipment 43
Terminal equipment 46
Power equipment 47
Signaling Server 49
Software architecture 55
Firmware 56
Software 56
Office data 56
Resident programs 56
Nonresident programs 57
Configuration options 58
Fiber Remote IPE 58
Carrier Remote IPE 61
Branch Office 62
Geographic Redundancy 62
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
5
.
New in this Release
There have been no updates to the document in this release.
Other
Revision History
September 2008
Standard 02.05. This document is up-issued to add content about FIJI
redesign in System modules chapter.
September 2008
Standard 02.04. This document is issued to support Communication Server
1000 Release 5.5.
July 2008
Standard 02.03. This document is issued to support Communication Server
1000 Release 5.5.
December 2007
Standard 02.02. This document is issued to support Communication Server
1000 Release 5.5.
June 2007 Standard 1.02. This document is up-issued to remove the Nortel Networks
Confidential statement.
May 2007
Standard 1.01. This document is issued to support Communication Server
1000 Release 5.0. This document contains information previously contained
in the following legacy document, now retired:
Communication Server 1000M
and Meridian 1: Large System Overview (553-3021-010),.
August 2005
Standard 3.00. This document is up-issued to support Communication Server
1000 Release 4.5.
September 2004
Standard 2.00. This document is up-issued for Communication Server 1000
Release 4.0.
October 2003
Standard 1.00. This document is a new NTP for Succession 3.0. It was
created to support a restructuring of the Documentation Library. This
document contains information previously contained in the following legacy
document, now retired: System Overview , (553-3001-100).
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
6 New in this Release
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
7
.
How to get help
This chapter explains how to get help for Nortel products and services.
Getting help from the Nortel Web site
The best way to get technical support for Nortel products is from the Nortel
Technical Support Web site: w
ww.nortel.com/support
This site provides quick access to software, documentation, bulletins, and
tools to address issues with Nortel products. From this site, you can:
download software, documentation, and product bulletins
search the Technical Support Web site and the Nortel Knowledge Base
for answers to technical issues
sign up for automatic notification of new software and documentation
for Nortel equipment
open and manage technical support cases
Getting help over the telephone from a Nortel Solutions Center
If you do not find the information you require on the Nortel Technical
Support Web site, and you have a Nortel support contract, you can also
get help over the telephone from a Nortel Solutions Center.
In North America, call 1-800-4NORTEL (1-800-466-7835).
Outside North America, go to the following Web site to obtain the
telephone number for your region: w
ww.nortel.com/callus
Getting help from a specialist by using an Express Routing Code
To access some Nortel Technical Solutions Centers, you can use an
Express Routing Code (ERC) to quickly route your call to a specialist in
your Nortel product or service. To locate the ERC for your product or
service, go to: w
ww.nortel.com/erc
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
8 How to get help
Getting help through a Nortel distributor or reseller
If you purchased a service contract for your Nortel product from a
distributor or authorized reseller, contact the technical support staff for that
distributor or reseller.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
9
.
Introduction
This document is a global document. Contact your system supplier or your
Nortel representative to verify that the hardware and software described
are supported in your area.
Subject
WARNING
Before a Large System can be installed, a network assessment
must be performed and the network must be VoIP-ready.
If the minimum VoIP network requirements are not met, the
system will not operate properly.
For information on the minimum VoIP network requirements and
converging a data network with VoIP, refer to
Converging the
Data Network with VoIP (NN43001-260),.
This document provides an overview of the general design and features of
CS 1000Mand Meridian 1 Large Systems.
Note on legacy products and releases
This NTP contains information about systems, components, and features
that are compatible with Nortel Communication Server 1000 Release 5.5
software. For more information on legacy products and releases, click the
Technical Documentation link under Support & Training on the Nortel
home page:
w
ww.nortel.com
Applicable systems
This document applies to the following systems:
Communication Server 1000E (CS 1000E) CP PII, CP PIV, and CP
PM.
Communication Server 1000M Single Group (CS 1000M SG) CP PII,
CP PIV
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
10 Introduction
Communication Server 1000M Multi Group (CS 1000M MG) CP PII,
CP PIV
Meridian 1 PBX 11C Chassis
Meridian 1 PBX 11C Cabinet
Meridian 1 PBX 61CCP PII, CP PIV
Meridian 1 PBX 81CCP PII, CP PIV
Note:
When upgrading software, memory upgrades may be required
on the Signaling Server, the Call Server, or both.
System migration
When particular Meridian 1 systems are upgraded to run CS 1000 Release
5.5 software and configured to include a Signaling Server, they become
CS 1000M systems. Table 1 lists each Meridian 1 system that supports an
upgrade path to a CS 1000M system.
Table 1
Meridian 1 systems to CS 1000M systems
This Meridian 1 system...
Maps to this CS 1000M system
Meridian 1 PBX 11C Chassis CS 1000E
Meridian 1 PBX 11C Cabinet CS 1000E
Meridian 1 PBX 61C CS 1000MSingle Group
Meridian 1 PBX 81C CS 1000MMulti Group
For more information, see Communication Server 1000M and Meridian 1:
Large System Upgrade Procedures (NN43021-458).,
Intended audience
This document is intended to be an introductory overview for individuals
responsible for the sale, acquisition, planning, or installation of CS
1000Mand Meridian 1 Large Systems.
Conventions
Terminology
In this document, the following systems are referred to generically as
"system":
Communication Server 1000M (CS 1000M)
Communication Server 1000E (CS 1000E)
Meridian 1
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
Related information 11
The following systems are referred to generically as "Large System":
Communication Server 1000M Single Group (CS 1000M SG)
Communication Server 1000M Multi Group (CS 1000M MG)
Meridian 1 PBX 61CCP PII, CP PIV
Meridian 1 PBX 81CCP PII, CP PIV
Related information
This section lists information sources that relate to this document.
NTPs
The following NTPs are referenced in this document:
IP Peer Networking Installation and Commissioning (NN43001-313),
Converging the Data Network with VoIP Fundamentals
(NN43001-260),
Branch Office Installation and Commissioning (NN43001-314),
System Redundancy Fundamentals (NN43001-507),
Telephones and Consoles Fundamentals (NN43001-567),
IP Phones Fundamentals (NN43001-368),
Communication Server 1000M and Meridian 1 Large System Planning
and Engineering (NN43021-220),
Fiber Remote IPE Fundamentals (NN43021-554),
Carrier Remote IPE Fundamentals (NN43021-555),
Fiber Remote Multi-IPE Interface Fundamentals (N43021-556),
WLAN Handsets Fundamentals (NN43001-505),
DECT Fundamentals (NN43120-114),
Signaling Server Installation and Commissioning (NN43001-312),
CD-ROM
To obtain Nortel documentation on CD-ROM, contact your Nortel customer
representative.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
12 Introduction
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
13
.
Product description
Contents
This section contains information on the following topics:
“Introduction” (page 13)
“System options” (page 15)
“CS 1000M HGand Meridian 1 Option 51C” (page 15)
“CS 1000M SGand Meridian 1 PBX 61C CP PIV” (page 18)
“CS 1000M MGand Meridian 1 PBX 81C CP PIV” (page 21)
“System modules” (page 24)
“NT4N41 Core/Network module” (page 24)
“NT5D21 Core/Network module” (page 26)
“NT8D35 Network module” (page 27)
“Fiber Network Fabric” (page 29)
“NT8D37 Intelligent Peripheral Equipment module” (page 30)
“Fiber Remote IPE module” (page 31)
“Carrier Remote IPE” (page 31)
Introduction
CAUTION
Before a Large System can be installed, a network assessment
must be performed and the network must be VoIP-ready.
If the minimum VoIP network requirements are not met, the
system will not operate properly.
For information on the minimum VoIP network requirements and
converging a data network with VoIP, refer to Converging the
Data Network with VoIP Fundamentals (NN43001-260),.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
14 Product description
All Large Systems consist of Universal Equipment Modules (UEM) stacked
one on top of another to form a column. Each column contains a pedestal,
a top cap, and up to four modules. A system can have one column or
multiple columns.
Each UEM is a self-contained unit that houses a card cage and backplane,
power and ground cabling, power units, input/output (I/O) panels, circuit
cards, and cables. When the card cage is installed, the function of the
UEM is established and the module is no longer "universal." The system
modules are as follows:
NT4N41 Core/Network module for CS 1000M MG, CS 1000M SG,
Meridian 1 PBX 81C CP PIV, and Meridian 1 PBX 61C CP PIV
NT5D21 Core/Network module for CS 1000M HG, CS 1000M SG, CS
1000M MG, Option 51C, 61C and 81C
NT8D35 Network module required for CS 1000M MGand Meridian 1
PBX 81C CP PIV, Option 81C
NT8D37 Intelligent Peripheral Equipment (IPE) module (required for
Large Systems)
Fiber Remote IPE module (optional for Large Systems Multi Group)
Carrier Remote IPE module (optional for Large Systems)
The pedestal generally houses a blower unit, air filter, Power Distribution
Unit (PDU), and System Monitor.
The top cap provides airflow exits, I/O cable entry and exit, and overhead
cable-rack mounting. Thermal sensor assemblies for the column are
attached to a perforated panel on top of the highest module in the column,
under the top cap.
A system can have one column or multiple columns. To comply with FCC
and CSA standards for containing electromagnetic interference and radio
frequency interference (EMI/RFI), spacer kits connect the columns in a
multiple-column system. If a Signaling Server is added to a previously
CISPR Class B system (previously used in some specific countries), the
system is now Compliant to Class A.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
System options 15
System options
This document includes information on the following Large Systems:
CS 1000M HGand Meridian 1 Option 51C: enhanced common control
complex, single CPU, and one half network group
CS 1000M SG, Meridian 1 PBX 61C CP PIV, and Meridian 1 Option
61C: enhanced common control complex, dual CPU, and one
full-network group
CS 1000M MG, Meridian 1 PBX 81C CP PIV, Meridian 1 Option 81,
and Meridian 1 Option 81C: enhanced common control complex, dual
CPU, and multiple-network groups
These systems are available in AC- and DC-powered versions.
CS 1000M HGand Meridian 1 Option 51C
The CS 1000M HGand the Meridian 1 Option 51C are single-CPU systems
with a half-network group. One Core/Network module and one IPE
module are required. Additional IPE modules, Remote IPE modules, and
application modules can be used.
Table 2 "Specifications for CS 1000M HGand Meridian 1 Option 51C"
(page 17) lists the specifications for these systems. Figure 1 "Meridian 1
Option 51C" (page 16) illustrates an Option 51C system.
With the addition of a Signaling Server, Meridian 1 Option 51C becomes
a CS 1000M HG. Figure 2 "CS 1000M HG" (page 16) on Figure 2 "CS
1000M HG" (page 16) illustrates a CS 1000M HG.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
16 Product description
Figure 1
Meridian 1 Option 51C
Figure 2
CS 1000M HG
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
System options 17
Table 2
Specifications for CS 1000M HGand Meridian 1 Option 51C
System characteristics:
Maximum number of ports
1000
Input voltage
208 V AC or –48 V DC
Number of CPUs
1
Number of network loops
16
Memory options:
Release 25
NT5D10 CP or NT5D03 CP card
Succession 3.0
CP3 NT5D10 CP or CP4 NT5D03 card
CS 1000 Release 4.5
CP3 NT5D10 CP or CP4 NT5D03 card
Software generic
2811
Base hardware:
Required per system:
SDI-type card
Required per module:
CE power supply (CEPS)
Call Processor (CP) card
Input/Output Disk Unit with CD-ROM (IODU/C)
Core to Network Interface (cCNI) card
3-Port Extender (3PE) card
Core/Network module
Clock Controller Card (MCLK)
IPE module
IPE power supply
IPE cards
System Monitor
PDU
Pedestal (one per column)
Blower unit
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
18 Product description
Table 2
Specifications for CS 1000M HGand Meridian 1 Option 51C (cont’d.)
Thermostat harness
Top cap (one per column)
Air probe harness
CS 1000M SGand Meridian 1 PBX 61C CP PIV
The CS 1000M SGand the Meridian 1 PBX 61C CP PIVare dual-CPU
systems with standby processing capability, fully redundant memory,
and a full-network group. Two cPCI Core/Network modules and one IPE
module are required. Additional IPE modules and application modules can
be used.
Figure 3 "Meridian 1 PBX 61C CP PIVor Meridian 1 Option 61C" (page
18) illustrates an Option 61C or Meridian 1 PBX 61C CP PIV.
With the addition of a Signaling Server, Option 61C or Meridian 1 PBX
61C CP PIVbecomes CS 1000M SG. Figure 4 "CS 1000M SG" (page
19) illustrates a CS 1000M SG.
Figure 3
Meridian 1 PBX 61C CP PIVor Meridian 1 Option 61C
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
System options 19
Figure 4
CS 1000M SG
Table 3 "Specifications for CS 1000M SGand Meridian 1 PBX 61C CP
PIV" (page 19) lists the specifications for CS 1000M SGand Meridian 1
PBX 61C CP PIV.
Table 3
Specifications for CS 1000M SGand Meridian 1 PBX 61C CP PIV
System characteristics:
Maximum number of ports
2000
Input voltage
208 V AC or –48 V DC
Number of CPUs
2 (redundant)
Number of network loops
32
Memory options:
Release 25
NT5D10 CP or NT5D03 CP card
Succession 3.0
CP3 NT5D10 or CP4 NT5D03 card
CS 1000 Release 4.5
CP3 NT5D10 or CP4 NT5D03 card
Software generic
2911
Base hardware:
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
20 Product description
Table 3
Specifications for CS 1000M SGand Meridian 1 PBX 61C CP PIV (cont’d.)
Required per system:
SDI-type card
Required per module:
Call Processor Pentium II
®
(CP PIV) card
System Utility (Sys Util) card
Core to Network Interface (cCNI) card
3-Port Extender (3PE) card
Peripheral Signaling card (PS)
Network cards
Superloop Network cards
Conference/TDS card
CE power supply
Hybrid Bus Terminators
Cards in the back of the module:
System Utility Transition (Sys Util Trans) card
Core/Network module (two)
cCNI Transition (cCNI Trans) card
IPE power supply
IPE cards
IPE module
Controller card
System Monitor
PDU
Pedestal (one per column)
Blower unit
Thermostat harness
Top cap (one per column)
Air probe harness
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

Nortel Networks NN43021-110 User manual

Category
Servers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI