Monogram ZV925SLSS Installation guide

Type
Installation guide

Monogram ZV925SLSS is a 36-inch Island Chimney Vent Hood designed to efficiently remove smoke, odor, and moisture from your kitchen. With its powerful ventilation system, it can handle up to 1200 CFM of airflow, ensuring a cleaner and fresher cooking environment. The hood features a 3-speed fan control, allowing you to adjust the fan speed based on your cooking needs. It also comes equipped with dishwasher-safe aluminum mesh filters that effectively capture grease and other particles, making cleaning a breeze.

Monogram ZV925SLSS is a 36-inch Island Chimney Vent Hood designed to efficiently remove smoke, odor, and moisture from your kitchen. With its powerful ventilation system, it can handle up to 1200 CFM of airflow, ensuring a cleaner and fresher cooking environment. The hood features a 3-speed fan control, allowing you to adjust the fan speed based on your cooking needs. It also comes equipped with dishwasher-safe aluminum mesh filters that effectively capture grease and other particles, making cleaning a breeze.

INSTALLATION
INSTRUCTIONS
36” Island Chimney Vent Hood
ZV925
MONOGRAM.COM
2 49-80329 Rev. 5
Safety Information
READ AND SAVE THESE INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ IMPORTANT Save these instructions
for local inspector’s use.
Ŷ IMPORTANT Observe all governing
codes and ordinances.
ŶNote to Installer Be sure to leave these
instructions with the Consumer.
ŶNote to Consumer Keep these instructions with
your Owner’s Manual for future reference.
ŶSkill Level Installation of this appliance requires
basic mechanical and electrical skills.
ŶCompletion Time — 1 to 3 Hours.
Ŷ3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW
covered under the warranty.
Ŷ)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDYLVLW
monogram.com.
Ŷ)RU0RQRJUDPVHUYLFHLQ&DQDGDYLVLWmonogram.ca
Ŷ)RU0RQRJUDP3DUWVDQG$FFHVVRULHVYLVLW
monogram.com/use-and-care/parts.
CAUTION
Due to the weight and size of these
vent hoods and to reduce the risk of personal injury
RUGDPDJHWRWKHSURGXFW TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION.
ATTENTION
À cause du poids et de la taille de
ces hottes et pour reduire le risque de blessures et
GHGRPPDJHVIL FAUT DEUX PERSONNES POUR
FAIRE L’INSTALLATION CORRECTEMENT.
WARNING
To reduce the risk of fire or electrical
VKRFNGRQRWXVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDO
VROLGVWDWHVSHHGFRQWUROGHYLFH$Q\VXFKDOWHUDWLRQ
from original factory wiring could result in damage to
the unit and/or create an electrical safety hazard.
AVERTISSEMENT
3RXUUpGXLUHOHULVTXH
G¶LQFHQGLHRXGHFKRFpOHFWULTXHLOQHIDXWSDV
XWLOLVHUFHWWHKRWWHDYHFXQUpJXODWHXUGHYLWHVVH
pOHFWURQLTXHH[WHUQH7RXWHPRGLILFDWLRQGHFHW\SHGX
branchement d’usine peute endommager l’appareil ou
FUpHUXQULVTXHGHFKRFpOHFWULTXH
TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING
725('8&(7+(5,6.2)),5(
(/(&75,&$/6+2&.25,1-85<723(56216
2%6(59(7+()2//2:,1*
$8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKH
PDQXIDFWXUHU,I\RXKDYHDQ\TXHVWLRQVFRQWDFW
the manufacturer.
%%HIRUHVHUYLFLQJRUFOHDQLQJWKHXQLWVZLWFKWKH
power off at the service panel and lock the service
disconnecting means to prevent the power from
EHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFH
GLVFRQQHFWLQJPHDQVFDQQRWEHORFNHGVHFXUHO\
IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJ
to the service panel.
AVERTISSEMENT
32855e'8,5(/(5,648(
'¶,1&(1',('(&+2&e/(&75,48(28'(
%/(6685(6,/)$872%6(59(5/(65(*/(6
68,9$17(6
$8WLOLVHUFHWDSSDUHLOXQLTXHPHQWGHODPDQLpUH
SUpYXHSDUOHIDEULFDQW(QFDVGHTXHVWLRQ
consulter le fabricant.
%$YDQWWRXWHLQWHUYHQWLRQRXQHWWR\DJHFRXSHU
O¶DOLPHQWDWLRQpOHFWULTXHDXGLVMRQFWHXUHWYHUURXLOOHU
OHSDQQHDXGXGLVMRQFWHXUSRXUpYLWHUODPLVHVRXV
tension accidentelle. S’il n’est pas possible de
YHUURXLOOHUOHSDQQHDXGXGLVFRQFWHXUDWWDFKHUXQ
SODFDUGRXXQHpWLTXHWWHWUpVYLVLEOHDXSDQQHDX
Ŷ)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVW
KD]DUGRXVRUH[SORVLYHPDWHULDOVRUYDSRUV
Ŷ6WUXFWXUDOIUDPLQJLQVWDOODWLRQZRUNDQGHOHFWULFDO
wiring must be done by qualified person(s) in
accordance with all applicable codes and standards
including fire-rated construction.
Ŷ6XIILFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG
H[KDXVWLQJRIJDVHVWKURXJKWKHIOXHFKLPQH\RIIXHO
EXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ)ROORZ
the heating equipment manufacturer’s guidelines
and safety standards such as those published by
WKH1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$DQG
WKH$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG
$LU&RQGLWLRQLQJ(QJLQHHUV$6+5$(DQGWKHORFDO
FRGHDXWKRULWLHV:KHQDSSOLFDEOHLQVWDOODQ\PDNHXS
(replacement) air system in accordance with local
EXLOGLQJFRGHUHTXLUHPHQWV9LVLW*($SSOLDQFHVFRP
for available makeup air solutions.
Ŷ/RFDOFRGHVYDU\,QVWDOODWLRQRIHOHFWULFDOFRQQHFWLRQV
and grounding must comply with applicable codes.
,QWKHDEVHQFHRIORFDOFRGHVWKHYHQWVKRXOGEH
LQVWDOOHGLQDFFRUGDQFHZLWK1DWLRQDO(OHFWULFDO&RGH
$16,1)3$RUODWHVWHGLWLRQ
CAUTION
To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH²GRQRWYHQW
H[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRUFHLOLQJVRULQWR
DWWLFVFUDZOVSDFHVRUJDUDJHV
ATTENTION
Il faut prendre soin d’installer
XQFRQGXLWYHUVO¶H[WpULHXUSRXUUpGXLUHOHULVTXH
G¶LQFHQGLHHWSRXYRLUpYDFXHUO¶DLUFRUUHFWHPHQW,O
QHIDXWSDVpYDFXHUO¶DLUFRUUHFWHPHQW,OQHIDXWSDV
pYDFXHUO¶DLUGDQVO¶HVSDFHHQWUHOHVSDURLVG¶XQPXU
XQSODIRQGRXXQJUHQLHUXQHVSDFHVDQLWDLUHRXXQ
garage.
49-80329 Rev. 5 3
Design Information
CONTENTS
Design Information
3URGXFW'LPHQVLRQV ...................................................... 3
Advance Planning
$GYDQFH3ODQQLQJ ........................................................ 4
3RZHU6XSSO\ ...............................................................4
'XFW)LWWLQJV ................................................................ 5
Installation Preparation
Tools and Materials Required ....................................... 6
5HPRYHWKH3DFNDJLQJ ................................................ 6
Installation Height .........................................................
3DUWV3URYLGHG .............................................................. 8
Installation Preparation
Construct Ceiling Support .............................................
Installation Instructions—Vented to the Outside
6WHS0RXQW7HPSODWH .............................................. 12
6WHS$GMXVW)UDPH+HLJKW ....................................... 12
6WHS&XW'XFWWR/HQJWKIRU9HQWHG,QVWDOODWLRQ...... 13
6WHS,QVWDOOWKH6XSSRUW)UDPH ............................... 13
6WHS,QVWDOO+RRG$WWDFKPHQW6FUHZV ..................... 13
6WHS0RXQWWKH+RRGRQWRWKH6XSSRUW .................. 14
6WHS&RQQHFW&DEOHV .............................................. 14
6WHS&RQQHFW(OHFWULFDO ........................................... 15
6WHS3UHSDUHWKH'XFW&RYHUV ................................ 16
6WHS,QVWDOO8SSHU'XFW&RYHU .............................. 16
6WHS,QVWDOO/RZHU'XFW&RYHU .............................. 
6WHS,QVWDOO'XFW&RYHU7ULP ................................. 
6WHS,QVWDOO0HWDO)LOWHU.......................................... 
6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 
Installation Instructions—Recirculating
6WHS0RXQW7HPSODWH .............................................. 18
6WHS$GMXVW)UDPH+HLJKW ....................................... 18
6WHS,QVWDOO$LU'HIOHFWRU&XW'XFW
for Recirculating Operation ............................. 
6WHS,QVWDOO8SSHU6XSSRUW)UDPH .......................... 
6WHS,QVWDOO/RZHU6WUXFWXUHWR8SSHU6WUXFWXUH ..... 
6WHS,QVWDOO%ORZHU0RWRU ........................................ 
6WHS,QVWDOO+RRG$WWDFKPHQW6FUHZV ..................... 
6WHS0RXQWWKH+RRGRQWRWKH6XSSRUW .................. 
6WHS&RQQHFW&DEOHV .............................................. 21
6WHS&RQQHFW(OHFWULFDO ......................................... 21
6WHS3UHSDUHWKH'XFW&RYHUV .............................. 22
6WHS,QVWDOO8SSHU'XFW&RYHU .............................. 22
6WHS,QVWDOO/RZHU'XFW&RYHU .............................. 22
6WHS,QVWDOO'XFW&RYHU7ULP ................................. 23
6WHS,QVWDOO)LOWHUV .................................................. 23
6WHS)LQDOL]H,QVWDOODWLRQ ....................................... 23
PRODUCT DIMENSIONS
These vent hoods are supplied with a support frame for
FHLOLQJKHLJKWVRI¶´WR¶´
Decorative duct covers conceal the ductwork running
from the top of the hood to the ceiling.
=;DFFHVVRU\LVDYDLODEOHIRUFHLOLQJKHLJKWVRI
¶´WR¶´
NOTE: Installation height should be measured from the
cooking surface to the bottom of the outer glass portion
of the hood.
7KLVKRRGPXVWEHLQVWDOOHG´PLQDQG´PD[
above the cooking surface. The cooking surface should
EHDWOHDVW´DERYHWKHIORRU
7KLVKRRGPD\EHYHQWHGWRWKHRXWGRRUVRULWFDQEH
installed for recirculating operation.
This hood can be installed over any Monogram electric
or gas cooktop. It cannot be installed over a Monogram
3URIHVVLRQDOFRRNWRSRUUDQJH
 7KHVXSSOLHGGXFWFRYHUILWV¶´WR¶FHLOLQJKHLJKWV
)RU¶´WR¶´FHLOLQJVRUGHU=;
27 9/16"
3 1/4"
35 7/8"
*Height
to
Ceiling
2 3/4"
*Height to
ceiling


24" min.*
PD[
36" min.
([DFWLQVWDOODWLRQ
height depends on
ceiling height.
4 49-80329 Rev. 5
Installation Preparation
ADVANCE PLANNING
Ductwork Planning
Ŷ7KHVHYHQWKRRGVDUHHTXLSSHGIRU´URXQG
ductwork.
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Ŷ3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH
)RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOG
QRWH[FHHGIWHTXLYDOHQWOHQJWKIRUDQ\GXFW
configurations.
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKH
PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH
outdoors.
Ŷ8VHULJLGPHWDOGXFWZRUNRQO\
Ŷ,QVWDOODURRIFDSZLWKGDPSHUDWWKHH[WHULRU
opening. Order the cap and any transitions needed
in advance.
Ŷ:KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQW
air system in accordance with local building code
UHTXLUHPHQWV9LVLW*($SSOLDQFHVFRPIRUDYDLODEOH
makeup air solutions.
Ductwork Planning
Ŷ7KHVHYHQWKRRGVDUHKHDY\$GHTXDWHVWUXFWXUDO
support must be provided. The ceiling structure
must be capable of supporting the weight of the
hood and any inadvertent user contact loads
DSSUR[LPDWHO\SRXQGV7KHKRRGVXSSRUW
IUDPHZLOOEHVXSSRUWHGE\[FURVVIUDPLQJ
Ŷ,QVWDOODWLRQZLOOEHHDVLHULIWKHYHQWKRRGLVLQVWDOOHG
before the cooktop or countertop below is installed.
Accessory Duct Cover
Ŷ$OOPRGHOVDUHVKLSSHGZLWKDGXFWFRYHUIRUFHLOLQJ
KHLJKWVRI¶´WR¶
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING
)253(5621$/6$)(7<7+,6
$33/,$1&(0867%(3523(5/<*5281'('
AVERTISSEMENT
3285'(65$,6216
'(6e&85,7e&(7$33$5(,/'2,7Ç75(
&255(&7(0(170,6¬/$7(55(
Remove house fuse or open circuit breaker before
beginning installation.
'RQRWXVHDQH[WHQVLRQFRUGRUDGDSWHUSOXJZLWK
WKLVDSSOLDQFH)ROORZ1DWLRQDOHOHFWULFDOFRGHVRU
prevailing local codes and ordinances.
Electrical supply
7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+]
DQGFRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHG
EUDQFKFLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLW
breaker or time delay fuse.
Ŷ:LULQJPXVWEHZLUHZLWKJURXQG
Ŷ,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH
proceeding.
Ŷ5RXWHKRXVHZLULQJLQWKHFHLOLQJDVFORVHWRWKH
LQVWDOODWLRQORFDWLRQDVSRVVLEOH$OORZDGGLWLRQDO
OHQJWKIURPFHLOLQJMRLVWVWRUHDFKWKHMXQFWLRQER[
on the bottom of the hood support frame.
Ŷ&RQQHFWWKHZLULQJWRWKHKRXVHZLULQJLQ
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
DJURXQGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil
GHPLVHjODWHUUHSHXWFDXVHUXQFKRFpOHFWULTXH(Q
FDVGHGRXWHFRQVXOWHUXQpOHFWULFLHQTXDOLILpRXXQ
WHFKQLFLHQSRXUGpWHUPLQHUVLO¶DSSDUHLOHVWjODWHUUH
=;DFFHVVRU\ duct cover is available
WRUHDFK1" WR1" ceiling heights. The
accessory should be ordered with the hood and be
on site before final framing and wall finishing.
49-80329 Rev. 5 5
Installation Preparation
DUCT FITTINGS
This Hood Must Use an 8” Round
Duct. It Can Transition to a
3-1/4” x 12” Duct.
8VHWKLVFKDUWWRFRPSXWHPD[LPXPSHUPLVVLEOHOHQJWKV
for duct runs to outdoors.
NOTE:'RQRWH[FHHGPD[LPXPSHUPLVVLEOHHTXLYDOHQW
lengths!
Maximum duct length: 100 foot for range hoods.
Flexible ducting
,IIOH[LEOHPHWDOGXFWLQJLVXVHGDOOWKHHTXLYDOHQWIHHW
YDOXHVLQWKHWDEOHVKRXOGEHGRXEOHG7KHIOH[LEOHPHWDO
GXFWVKRXOGEHVWUDLJKWDQGVPRRWKDQGH[WHQGHGDV
much as possible.
DO NOTXVHIOH[LEOHSODVWLFGXFWLQJ
NOTE: $Q\KRPHYHQWLODWLRQV\VWHPVXFKDVD
YHQWLODWLRQKRRGPD\LQWHUUXSWWKHSURSHUIORZRI
FRPEXVWLRQDLUDQGH[KDXVWUHTXLUHGE\ILUHSODFHVJDV
IXUQDFHVJDVZDWHUKHDWHUVDQGRWKHUQDWXUDOO\YHQWHG
systems. To minimize the chance of interruption of such
QDWXUDOO\YHQWHGV\VWHPVIROORZWKHKHDWLQJHTXLSPHQW
manufacturer’s guidelines and safety standards such
DVWKRVHSXEOLVKHGE\1)3$DQG$6+5$(:KHQ
DSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQWDLUV\VWHP
in accordance with local building code requirements. Visit
GEAppliances.com for available makeup air solutions.
Duct Piece Dimensions
Equivalent
Length*
Quantity
Used
Total
Equivalent
Length
5RXQG
straight
1 ft. (per foot
length)
´[´
straight
1 ft. (per foot
length)
HOERZ IW
HOERZ IW
´[´
HOERZ
43 ft.
´[´
HOERZ
26 ft.
´[´
IODW
elbow
IW
´URXQGWR
´[´
transition
2 ft.
´[´
WR´URXQG
transition
5 ft.
´URXQGWR
´[´
WUDQVLWLRQ
elbow
6 ft.
´[´
WR´URXQG
WUDQVLWLRQ
elbow
13 ft.
Round wall
cap with
damper
32 ft.
´[´
wall cap with
damper
IW
Round roof
cap
44 ft.
$FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFWILWWLQJ
equivalent. Equivalent length of duct pieces
DUHEDVHGRQDFWXDOWHVWVFRQGXFWHGE\*(
$SSOLDQFHV(YDOXDWLRQ(QJLQHHULQJDQGUHIOHFW
requirements for good venting performance
with any ventilation hood.
Total Duct Run
6 49-80329 Rev. 5
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
REMOVE THE PACKAGING
CAUTION
/,)77+(+22'2872)7+(%2;
%<7+(&(17(50(7$/3257,21'2127/,)7%<
7+(*/$666,'(6
ATTENTION
/(9(=/$+277(¬/¶(;7e5,(85
'(/$%2Ì7(3$5/$3257,210e7$/&(175$/
1(/(9(=3$63$5/(6&Ð7e6'(9(55(
CAUTION
:HDUJORYHVWRSURWHFWDJDLQVW
sharp edges.
ATTENTION
3RUWH]GHVJDQWVSRXUpYLWHUOHV
EOHVVXUHVFDXVpHVSDUOHVWUDQFKDQWV
Ŷ*UDVSWKHKRRGE\WKHPHWDOLQVHUWLQWKHFHQWHUDQG
OLIWVWUDLJKWXSDQGRXWRIWKHER[
Ŷ5HPRYHDQGSURSHUO\GLVFDUGWKHSODVWLFZUDSSLQJ
Ŷ5HPRYHSDUWVER[GXFWFRYHUVDQGRWKHUSDFNDJLQJ
3HQFLODQGWDSHPHDVXUH
3OLHUV
9+]RU$PS
2-wire with ground. properly
grounded branch circuit.
Key hole saw
:LUHFXWWHUVWULSSHU
Step ladder
Metal snips
Saber saw
or sawsall
:LUHQXWV
3KLOOLSVDQG
flat blade
screwdrivers
Strain relief for
junction cover.
Spirit level
)ODVKOLJKW
Safety glasses
8" round metal
GXFWOHQJWKWR
suit installation.
Duct tape
3/8" swivel
socket or pivoting
KH[VRFNHWZLWK
H[WHQVLRQV
Carpenter’s square
Hammer
Electric or battery-operated drill
DQGELWV3KLOOLSVDQGIODW
blade screwdriver bits.
49-80329 Rev. 5
Installation Preparation
DETERMINE INSTALLATION HEIGHT
Ŷ'HFRUDWLYHGXFWFRYHUVDUHSURYLGHGWRFRQFHDOWKH
ductwork running to the ceiling.
Ŷ7KLVKRRGFDQEHLQVWDOOHGIRUUHFLUFXODWLQJ
RSHUDWLRQ1RNLWVUHTXLUHG
7KHKRRGLQVWDOODWLRQKHLJKWIURPWKHFRRNLQJVXUIDFH
WRWKHERWWRPRIWKHKRRGGHSHQGVXSRQFHLOLQJ
height.
)RURSWLPXPSHUIRUPDQFHWKHKRRGPXVWEH´PLQ
DQG´PD[DERYHWKHFRRNLQJVXUIDFH
Use the chart on this page to accurately determine
LQVWDOODWLRQKHLJKWDQGVXSSRUWIUDPHDGMXVWPHQWDQG
WRVHOHFWWKHFRUUHFWVL]HWRSWULPSLHFH$%&RU'
=;$FFHVVRU\'XFWFRYHULQFOXGHVD´
long duct cover and 3 sets of duct cover top trim
SLHFHVODEHOHG()*
D
C
B
$
Ceiling
Height
Possible Hood
Installation
Height (inches)
Mounting Frame
Height (inches)
Trim
Needed
 26  $
8’   $
 24 34 1/2 B
 28  $
 25 34 1/2 B
   $
3" 26 34 1/2 B
   $
  34 1/2 B
 24 38 1/2 C
 28 34 1/2 B
 25 38 1/2 C
  34 1/2 B
 26 38 1/2 C
  34 1/2 B
  38 1/2 C
 24 42 1/2 D
 28 38 1/2 C
 25 42 1/2 D
  38 1/2 C
 26 42 1/2 D
  38 1/2 C
  42 1/2 D
ZX92510 Accessory Duct Cover
 24 46 1/2 E
 28 42 1/2 D
 25 46 1/2 E
  42 1/2 D
 26 46 1/2 E
3"  42 1/2 D
  46 1/2 E
 24  )
 28 46 1/2 E
 25  )
  46 1/2 E
 26  )
  46 1/2 E
   )
 24 54 1/2 *
 28  )
 25 54 1/2 *
   )
 26 54 1/2 *
   )
  54 1/2 *
 28 54 1/2 *
8 49-80329 Rev. 5
Installation Preparation
PARTS PROVIDED
Locate the parts packed with the hood.
HARDWARE PACKAGE
Locate and check
contents. Screws
shown actual size.
$LUGHIOHFWRUIRU
recirculating installation
49-80406
Printed in Italy 04-06 JR
36Hood
Template
8-1/2
Dia.
Cut a 1Dia.
Wire Access
Hole
Cut a 1Dia.
Wire Access
Hole
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
10-1/16to
Centerline
of Holes
7-1/16to
Centerline
of Holes
FRONT OF HOOD
7-1/16to
Centerline
of Holes
Template
6 ceiling
mounting
screws
VFUHZVWRWDO
24 support frame screws
KRRGDWWDFKPHQW
screws
2 upper duct cover
attachment screws
4 recirculating
deflector screws
2 duct cover bracket
attachment screws
12 sheet
metal
screws
Decorative duct covers
(14"ZLGHGHHSZKHQDVVHPEOHG
12 cage
nuts
Telescoping support
frame
Upper duct cover trim pieces
2 each of 4 sizes
1 charcoal filter for
recirculating installation
Stainless steel filter
24-3/4"
23-1/4"
2 Duct cover
brackets
2 thumb
screws
Lower duct cover trim pieces
Note: Some additional hardware/screws included.
49-80329 Rev. 5
Installation Preparation
CONSTRUCT CEILING SUPPORT
Plan the Location of the Hood and Ductwork
ŶUse a plumb bob to check the location. The
countertop/cooktop below the hood must be
centered with the hood.
Ŷ7KHKRRGVKRXOGH[WHQGEH\RQGWKHIURQW
and rear edge of the cooking appliance.
ŶThe duct in the ceiling must be centered
over the cooktop.
Ceiling Support Structure
Ŷ$WWKHKRRGORFDWLRQLQVWDOO[FURVVIUDPLQJ
EHWZHHQFHLOLQJMRLVWVDVVKRZQ[¶VDUHUHTXLUHGWR
support the weight of the hood.)
Ŷ$UUDQJHFURVVIUDPLQJLQWKHFHLOLQJWRVXLWWKHH[LVWLQJ
structure.
Ŷ<RXUFHLOLQJMRLVWVZLOOEHOLNHRQHRIWKHIROORZLQJ
H[DPSOHV
Ceiling
Hood ducting
centerline
Cooktop
Countertop
)URQW

13-3/4"
Side view
$OLJQZLWKFHQWHU
of cooktop
Top view ceiling joists parallel to front of hood

Install cross-framing
symmetrically over duct/
cooktop centerline
16" joist
spacing

´GXFW
)URQW
of
hood
[FURVV
framing
Cooktop
outline
$OLJQGXFWWR
center of cooktop
(;$03/($
 49-80329 Rev. 5
Installation Preparation
CONSTRUCT CEILING SUPPORT (Cont.)
Top view ceiling joists run perpendicular to front of hood
Top view ceiling joists at angle to front of hood
LQVWDOO
cross-framing
symmetrically over
duct/cooktop
centerline
16" joist
spacing

8" duct
)URQW
of
hood
[FURVV
framing
Cooktop
outline
$OLJQGXFW
to center of
cooktop
LQVWDOOFURVV
framing symmetrically over
duct/cooktop centerline
16" joist
spacing

8" duct
)URQW
of
hood
[FURVV
framing
Cooktop
outline
$OLJQGXFW
to center of
cooktop
(;$03/(%
(;$03/(&
49-80329 Rev. 5 11
Installation Preparation
CONSTRUCT CEILING SUPPORT (Cont.(
Ŷ6HFXUHHDFK[EORFNZLWKDWOHDVWIRXU
ZRRGVFUHZV´ORQJQRWVXSSOLHG8VHZRRG
screws total for the two supports.
ŶThe cross framing must be accurately aligned to
assure correct positioning of the hood.
ŶThe cross framing must be level in all directions.
Check with a spirit level and adjust if necessary.
IMPORTANT: The ceiling structure must be capable of
VXSSRUWLQJWKHZHLJKWRIWKHKRRGDSSUR[LPDWHO\
pounds) and any inadvertent user contact loads. The
KRRGVXSSRUWIUDPHZLOOEHVXSSRUWHGE\WKH[FURVV
framing.
Ductwork for Installations Vented to the Outdoors
Ŷ8VHWKHVKRUWHVWDQGVWUDLJKWHVWGXFWURXWHSRVVLEOH
)RUVDWLVIDFWRU\SHUIRUPDQFHGXFWUXQVKRXOGQRW
H[FHHGIHHWHTXLYDOHQWOHQJWKIRUDQ\GXFW
configuration.
Ŷ5HIHUWR³'XFW)LWWLQJV´FKDUWWRFRPSXWHWKH
PD[LPXPSHUPLVVLEOHOHQJWKIRUGXFWUXQVWRWKH
outdoors.
Ŷ7KLVYHQWKRRGPXVWXVH´URXQGULJLGGXFW
Ŷ,QVWDOOWKHKRXVHGXFWZRUNWRUXQKRUL]RQWDOO\EHWZHHQ
ceiling joists or straight up through the roof.
Finish the Ceiling
Ŷ)LQLVKWKHFHLOLQJVXUIDFH%HVXUHWRPDUNORFDWLRQRI
the ceiling joists and cross framing. Check to be sure
the ceiling is level; use shims if necessary.
Ceiling Joint
2x4
10"
Duct
Vent Straight Up
Through The Ceiling
8" Duct
Ceiling joist
[
Vent straight up through
the ceiling
Ceiling
Joist
10-3/4
2x 4
Mi
n.
Cross Framing
Height
Adjustment
Screw Holes
7-1/16"
[PLQFURVVIUDPLQJ
Ceiling
joist


Height
adjustment
screws
12 49-80329 Rev. 5
Installation Instructions
1
MOUNT TEMPLATE
Ŷ$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQG
tape in place.
Be sure the template is oriented correctly with the
front of the hood.
Ŷ8VHDSOXPEEREWREHVXUHWKHPRXQWLQJKROHV
will provide parallel alignment with the countertop
below.
Ŷ&HQWHUSXQFKDOOKROHORFDWLRQV
Ŷ'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHD´
ELWDQGGULOODSSUR[LPDWHO\´GHHS
Ŷ'ULYHKH[KHDGZRRGVFUHZVLQWRWKHFHQWHURIWKH
FHLOLQJMRLVWVDQGFURVVIUDPLQJ/HDYHD´JDSWR
allow the screw head to engage the keyhole slots on
the support frames.
Ŷ&XWWKH´GXFWRSHQLQJWKURXJKWKHVKHHWURFN
2
ADJUST FRAME HEIGHT
Ŷ0HDVXUHH[DFWFHLOLQJKHLJKW
Ŷ)LQGWKHH[DFWIUDPHKHLJKWUHTXLUHG
RQWKHFKDUWRQSDJH
Ŷ5HPRYHVFUHZVRQHDFKRIWKH
sides of the frame to loosen the upper
VWUXFWXUHORZHUVWUXFWXUHDQGEORZHU
motor.
Ŷ$GMXVWWKHKHLJKW³;´DFFRUGLQJWR
WKHFKDUWRQSDJH8VHDWRWDORI
32 screws (8 screws on each side)
WRVHFXUHWKHXSSHUVWUXFWXUHORZHU
structure and blower/motor together.
INSTALLATION—VENTED TO THE OUTSIDE
1/4" Gap
49-80406
Printed in Italy 04-06 JR
36Hood
Template
8-1/2
Dia.
Cut a 1Dia.
Wire Access
Hole
Cut a 1Dia.
Wire Access
Hole
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
10-1/16to
Centerline
of Holes
7-1/16to
Centerline
of Holes
FRONT OF HOOD
7-1/16to
Centerline
of Holes
24"min.
PD[
36"min.
)UDPH
height
2-3/4"
Ceiling
height
X
49-80329 Rev. 5 13
Installation Instructions
3
CUT DUCT TO LENGTH FOR
VENTED
Ŷ0HDVXUHIURPKRXVH
GXFWWRH[KDXVW
opening.
Ŷ&XWWKH´GXFWOHQJWK
to size.
Ŷ6OLSGXFWRYHUWKH
H[KDXVWRSHQLQJ
Ŷ6HDOWKHFRQQHFWLRQ
with duct tape.
5
INSTALL HOOD ATTACHMENT
SCREWS
Ŷ,QVWDOOKRRGDWWDFKPHQWVFUHZVLQWKHERWWRPRI
WKHVXSSRUWDVVKRZQ/HDYH´JDSEHWZHHQ
screw head and support flange.
4
INSTALL THE SUPPORT FRAME
Ŷ5DLVHWKHVXSSRUWWRZDUG
the ceiling.
Ŷ7KUHDGWKHKRXVHZLULQJ
through one of the large
KROHVSUHIHUDEO\RQWKHOHIW
side.
Ŷ&DUHIXOO\HQJDJHWKH
ceiling mounting screws to
WKHNH\KROHVORWV$1'WKH
house duct in the top of the
frame.
Ŷ7LJKWHQWKHPRXQWLQJ
screws against the frame.
Ŷ,QVWDOOVDIHW\VFUHZV
Ŷ8VHGXFWWDSHWRVHDOWKH
duct connection at the top.
INSTALLATION—VENTED TO THE OUTSIDE
Duct
House
duct
)UDPH
height
Duct
length
Duct
Safety screws
Keyhole
slots
House wiring
Keyhole
slots
Install 4
attachment
screws
14 49-80329 Rev. 5
Installation Instructions
INSTALLATION—VENTED TO THE OUTSIDE
7
CONNECT CABLES
Ŷ-RLQWKHWZRFDEOHFRQQHFWRUVDWWKHIURQWRIWKH
hood. Secure the cables behind the retainer clip.
6
MOUNT THE HOOD ONTO THE
SUPPORT
WARNING
2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT
,IIDXWGHX[SHUVRQQHVSRXU
lever et mettre en place la hotte sur le support de
montage.
Ŷ/LIWWKHKRRGWRWKHERWWRPRIWKHVXSSRUWHQJDJLQJ
the keyhole slots to the 4 mounting screws.
Ŷ7LJKWHQWKHPRXQWLQJVFUHZV
Ŷ,QVWDOODGGLWLRQDOVFUHZVDVVKRZQ
Install
6 screws
Retainer clip
To lights
To control
panel
49-80329 Rev. 5 15
Installation Instructions
8
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with a
JURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKHLQVWDOOHU
:KHQKRXVHZLULQJLVDOXPLQXPEHVXUHWRXVH8/
DSSURYHGDQWLR[LGDQWFRPSRXQGDQGDOXPLQXPWR
copper connectors.
AVERTISSEMENT
Si le câblage de la maison n’est
SDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUHO¶LQVWDOODWHXU
GRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHVILOVGHOD
PDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQG¶XWLOLVHUGHOD
SkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HWGHVFRQQHFWHXUV
pour l’aluminium-cuivre.
Ŷ5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXWRQWKH
left side.
Ŷ6HFXUHWKHKRXVHZLULQJWRWKHMXQFWLRQER[ZLWK
a strain relief.
Ŷ
Connect white leads to branch circuit white lead.
Ŷ&RQQHFWEODFNOHDGVWREUDQFKFLUFXLWEODFNOHDG
Ŷ&RQQHFWJUHHQ\HOORZOHDGVWREUDQFKFLUFXLWJUHHQ
lead or bare ground lead.
Ŷ6HFXUHDOOFRQQHFWLRQVZLWKZLUHQXWVRQHDFK
electrical connector.
Ŷ3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU
Be sure wires are not pinched.
Ŷ6HFXUH-%R[FRYHUZLWKRULJLQDOVFUHZ
Knockout
-%R[FRYHU
INSTALLATION—VENTED TO THE OUTSIDE
-%R[FRYHU
House wiring
16 49-80329 Rev. 5
Installation Instructions
9
PREPARE THE DUCT COVERS
Ŷ5HPRYHWKHSODVWLFSURWHFWLYHFRYHULQJRQDOOGXFW
pieces.
Ŷ,QVWDOOFDJHQXWVRQHDFKLQVLGHVHFWLRQRIWKHWRS
duct cover. The cage nuts fit into the rectangular
VORWVFOLSVIDFLQJRXWZDUG
Ŷ,QVWDOOFDJHQXWVRQHDFKVLGHRIWKHORZHUGXFW
covers.
10
INSTALL UPPER DUCT COVER
Ŷ3ODFHWKHWDOOGXFWFRYHUVRQWRWKHWRSRIWKHKRRG
This section has venting holes on one end.
NOTE: If you are installing this hood for
UHFLUFXODWLQJRSHUDWLRQSODFHWKHGXFWFRYHUVRQWR
the hood with the venting slots at the top.
,IWKHKRRGLVYHQWHGWRWKHRXWVLGHWKHKROHV
should be positioned on the bottom.
Ŷ6HFXUHWKHVLGHVZLWKVFUHZVLQVWDOOHGWKURXJKWKH
cage nuts.
Ŷ5DLVHWKHDVVHPEOHGGXFWFRYHUVWRWKHWRSDJDLQVW
the ceiling.
Ŷ0DWFKPRXQWLQJKROHVRQHRQHDFKVLGH,QVWDOO
screws through the duct and into the support.
INSTALLATION—VENTED TO THE OUTSIDE
Support
frame
3ODQ
diagram
Rectangular slots
1XW
Top
sections
Top
sections
49-80329 Rev. 5 
Installation Instructions
11
INSTALL LOWER DUCT
Ŷ3ODFHUHDUGXFWFRYHURQWRWKHKRRG
Ŷ3ODFHIURQWGXFWFRYHURQWRWKHKRRG
Ŷ6HFXUHWKHGXFWFRYHUVZLWKVFUHZV
12
INSTALL DUCT COVER TRIM
Ŷ,QVWDOOVLGHEUDFNHWVWRVHFXUHWKHORZHUGXFWWLJKWO\
against the upper duct.
Ŷ+ROGORZHUWULPVWULSVQDUURZSLHFHVZLWKKRRNV
IDFLQJGRZQ3ODFHWKHKRRNVLQVLGHWKHVORWVDQG
slide downward.
Ŷ6HOHFWWKHFRUUHFWVL]HXSSHUWULPVWULSVDQGSUHVV
into place.
13
INSTALL METAL FILTER
IMPORTANT:&KHFNWREHVXUHWKDWWKHPDLQ21
2))VZLWFKQH[WWRWKHPRWRULVLQWKH21SRVLWLRQ
Ŷ7LSWKHILOWHULQWRWKHOHIWRUULJKWVLGHRIWKHRSHQLQJ
Lift the filter to the opposite side and into the filter
lock.
Ŷ7RUHPRYHWKHILOWHUSXOOWKHILOWHUORFNGRZQZDUG
14
FINALIZE INSTALLATION
Ŷ5HPRYHDOOWDSHDQGSDFNLQJPDWHULDO
Ŷ5HIHUWRWKH2ZQHU¶V0DQXDOIRURSHUDWLQJ
instructions.
INSTALLATION—VENTED TO THE OUTSIDE
)URQWERWWRPGXFWFRYHUVHFWLRQ
(snap into place and secure
with 6 screws 3 per side)
3ODQGLDJUDPWRS
view
)URQWERWWRPGXFW
cover sections
Upper
trim
strip
Lower
trim strip
Lower
trim
strip
Upper
trim
strip
Side
bracket
)LOWHUORFN
18 49-80329 Rev. 5
Installation Instructions
1
MOUNT TEMPLATE
Ŷ$OLJQWKHWHPSODWHZLWKWKHPDUNVRQWKHFHLOLQJDQG
tape in place.
Be sure the template is oriented correctly with the
front of the hood.
Ŷ8VHDSOXPEEREWREHVXUHWKHPRXQWLQJKROHV
will provide parallel alignment with the countertop
below.
Ŷ&HQWHUSXQFKDOOKROHORFDWLRQV
Ŷ'ULOOSLORWKROHVLQWKHVFUHZORFDWLRQV8VHD´
ELWDQGGULOODSSUR[LPDWHO\´GHHS
Ŷ'ULYHKH[KHDGZRRGVFUHZVLQWRWKHFHQWHURIWKH
FHLOLQJMRLVWVDQGFURVVIUDPLQJ/HDYHD´JDSWR
allow the screw head to engage the keyhole slots on
the support frames.
Ŷ&XWWKH´GXFWRSHQLQJWKURXJKWKHVKHHWURFN
2
ADJUST FRAME HEIGHT
Ŷ0HDVXUHH[DFWFHLOLQJKHLJKW
Ŷ)LQGWKHH[DFWIUDPHKHLJKWUHTXLUHG
RQWKHFKDUWRQSDJH
Ŷ5HPRYHVFUHZVRQHDFKRIWKH
sides of the frame to loosen the upper
VWUXFWXUHORZHUVWUXFWXUHDQGEORZHU
motor.
Ŷ$GMXVWWKHKHLJKW³;´DFFRUGLQJWR
WKHFKDUWRQSDJH8VHDWRWDORI
32 screws (8 screws on each side)
WRVHFXUHWKHXSSHUVWUXFWXUHORZHU
structure and blower/motor together.
INSTALLATION—VENTED TO THE OUTSIDE
1/4" Gap
49-80406
Printed in Italy 04-06 JR
36Hood
Template
8-1/2
Dia.
Cut a 1Dia.
Wire Access
Hole
Cut a 1Dia.
Wire Access
Hole
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
Drill 3/16
Pilot Holes
Approx. 1-1/2
Deep
10-1/16to
Centerline
of Holes
7-1/16to
Centerline
of Holes
FRONT OF HOOD
7-1/16to
Centerline
of Holes
24"min.
PD[
36"min.
)UDPH
height
2-3/4"
Ceiling
height
X
Mark
each
piece to
indicate
where
screw
holes
align.
NOTE: Low ceilings may require that the
lower portion of the support frame be removed.
The upper support frame may be secured
directly to the blower/motor. Refer to the
FKDUWRQSDJHIRU\RXUFHLOLQJKHLJKWDQG
to be sure the duct cover trim piece will fit.
49-80329 Rev. 5 
3
INSTALL AIR DEFLECTOR,
CUT DUCT FOR RECIRCULATING
OPERATION
Ŷ7HPSRUDULO\VOLGHWKHDLUGHIOHFWRU
into the support frame.
Ŷ0HDVXUHGXFWOHQJWKEHWZHHQ
the deflector and over the
H[KDXVWRSHQLQJ
Ŷ&XWGXFWSLHFHWROHQJWKDQG
set aside.
4
INSTALL UPPER SUPPORT
FRAME
Ŷ5DLVHWKHXSSHUVXSSRUW
toward the ceiling.
Ŷ7KUHDGWKHKRXVHZLULQJ
through one of the large
KROHVSUHIHUDEO\RQWKHOHIW
side.
Ŷ&DUHIXOO\HQJDJHWKHFHLOLQJ
mounting screws to the
keyhole slots in the top of
the frame.
Ŷ7LJKWHQWKHPRXQWLQJVFUHZVDJDLQVWWKHIUDPH
Ŷ,QVWDOOVDIHW\VFUHZV
Ŷ6OLGHDLUGHIOHFWRU
into the support
frame.
Ŷ6HFXUHWKHGHIOHFWRU
to the support with
4 screws.
Ŷ,QVWDOOWKHGXFW
piece to the bottom
of the deflector
and seal the
connection with
duct tape.
Installation Instructions
INSTALLATION—RECIRCULATING
)5217
)5217
Duct
length
Safety
screws
Keyhole
slots
House wiring
Keyhole
slots
 49-80329 Rev. 5
Installation Instructions
INSTALLATION—RECIRCULATING
5
INSTALL LOWER STRUCTURE TO
UPPER STRUCTURE
Ŷ6OLGHORZHUIUDPHLQWRWKH
upper frame. Match the
marked alignment holes.
Ŷ6HFXUHWKHXSSHUDQGORZHU
IUDPHZLWKVFUHZVRQ
each side of the frame.
7
INSTALL HOOD ATTACHMENT
SCREWS
Ŷ,QVWDOOKRRGDWWDFKPHQWVFUHZVLQWKHERWWRPRI
WKHVXSSRUWDVVKRZQ/HDYH´JDSEHWZHHQ
screw head and support flange.
8
MOUNT THE HOOD ONTO THE
SUPPORT
WARNING
2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT
,IIDXWGHX[SHUVRQQHVSRXU
lever et mettre en place la hotte sur le support de
montage.
Ŷ/LIWWKHKRRGWRWKHERWWRP
RIWKHVXSSRUWHQJDJLQJ
the keyhole slots to the 4
mounting screws.
Ŷ7LJKWHQWKHPRXQWLQJ
screws.
Ŷ,QVWDOO
additional
screws as
shown.
6
INSTALL BLOWER/MOTOR
Ŷ5DLVHWKHEORZHU
motor piece toward the
assembled frame.
Ŷ&DUHIXOO\UDLVHWKHPRWRUWR
the marked reference point
while making sure the duct
piece slips over the blower
outlet flange.
Ŷ6HFXUHWKHEORZHUPRWRUWR
WKHIUDPHXVLQJVFUHZV
4 on each side.
Ŷ8VHWDSHWRVHDOWKHGXFW
connection.
Install 4
attachment
screws
Install 6 screws
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Monogram ZV925SLSS Installation guide

Type
Installation guide

Monogram ZV925SLSS is a 36-inch Island Chimney Vent Hood designed to efficiently remove smoke, odor, and moisture from your kitchen. With its powerful ventilation system, it can handle up to 1200 CFM of airflow, ensuring a cleaner and fresher cooking environment. The hood features a 3-speed fan control, allowing you to adjust the fan speed based on your cooking needs. It also comes equipped with dishwasher-safe aluminum mesh filters that effectively capture grease and other particles, making cleaning a breeze.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI