Lacon L-EX73000 Quick start guide

Category
Network switches
Type
Quick start guide
Hardened Managed Ethernet Switch
Users Manual 1
Quick Start Guide
This quick start guide describes how to install and use the
Hardened Managed Ethernet Switch. This is the switch of
choice for harsh environments constrained by space.
Physical Description
The Port Status LEDs and Power Inputs
Hardened Managed Ethernet Switch
2 Users Manual
LED State Indication
Steady Power on Power 1
Power 2
Power 3 Off Power off
10/100Base-TX, 100Base-FX
Steady A valid network connection established
Link/ACT
Flashing Transmitting or receiving data
ACT stands for ACTIVITY
10/100/1000Base-TX (Green), 1000Base-SX/LX (Orange)
Steady A valid network connection established
Link/ACT
Flashing Transmitting or receiving data
ACT stands for ACTIVITY
Power Input Assignment
Power3 12VDC DC Jack
12-48VDC
Power2 Power Ground
12-48VDC
Power1 Power Ground
Earth Ground
Terminal
Block
Relay Output Rating 1A @ 24VDC
Relay Alarm Assignment
FAULT
*Warning signal disable for following:
The relay contact closes if Power1 and Power2
are both failed but Power3 on.
The relay contact closes if Power3 is failed but
Power1 and Power2 are both on.
Hardened Managed Ethernet Switch
Users Manual 3
Functional Description
z Meets NEMA TS1/TS2 Environmental requirements such as
temperature, shock, and vibration for traffic control equipment.
z Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity
for industrial environment.
z Manageable via SNMP, Web-based, Telnet, and RS-232 console port.
z Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
1000Mbps-full-duplex; 10/100Mbps-full/half-duplex; Auto MDI/MDIX.
z 100Base-FX: Multi mode SC or ST type; Single mode SC or ST type;
WDM Single mode SC type.
z 1000Base-SX/LX: Multi mode SC type, Single mode SC type, or WDM
Single mode SC type.
z Supports 8192 MAC addresses. Provides 2M bits memory buffer.
z Store-and-forward mechanism.
z Full wire-speed forwarding rate.
z Alarms for power and port link failure by relay output.
z Power Supply: Redundant DC Terminal Block power inputs and
12VDC DC JACK with 100-240VAC external power supply. "For Use
with Model UP0351E-12P as power jack supply source by Universal
Micro Electronics Co., Ltd.".
z Field Wiring Terminal: Use Copper Conductors Only, 60/75, 14-24
AWG torque value 4.5 lb-in.
z Operating voltage and Max. current consumption: 1.25A @ 12VDC,
0.625A @ 24VDC, 0.313A @ 48VDC. Power consumption: 15W Max.
z -40 to 75 (-40 to 167) operating temperature range. Tested for
functional operation @ -40 to 85 (-40 to 185). UL508
Industrial Control Equipment certified Maximum Surrounding Air
Temperature @ 75 (167).
z For use in Pollution Degree 2 Environment.
z Supports DIN-Rail and Panel Mounting installation.
z Suitable for use in Class I, Division 2, Groups A, B, C and D hazardous
locations, or nonhazardous locations only.
z WARNING – EXPLOSION HAZARD – Do not disconnect equipment
while the circuit is live or unless the area is known to be free of
ignitable concentrations.
z WARNING – EXPLOSION HAZARD – Substitution of any component
may impair suitability for Class I, Division 2.
z WARNING – Exposure to some chemicals may degrade the sealing
properties of materials used in the Sealed Relay Device.
Hardened Managed Ethernet Switch
4 Users Manual
z RECOMMENDATION - It is recommended to inspect the sealed relay
device periodically and to check for any degradation of the materials
and to replace the complete product, not the sealed device, if any
degradation is found.
z Sealed Relay Device information: Sealed Device: Relay Type
V23079-A2008-B301, manufactured by Tyco Electronics Logistics Ag.
Relay Cover: Manufacture of Plastic Material – Ticona.
Designation of Plastic Material – Vectra A130.
Relay Epoxy: Manufacture of Material – Guangzhou Wells
Chemical Co. Ltd. Designation of Material – Type 6060RP.
Generic Name of Plastic Material – Epoxy Resin.
Hardened Managed Ethernet Switch
Users Manual 5
Console Configuration
z Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device
and the RS-232 serial port of the terminal or computer running the
terminal emulation application. Direct access to the administration
console is achieved by directly connecting a terminal or a PC equipped
with a terminal-emulation program (such as HyperTerminal) to the
switch console port.
z Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none.
z Press the “Enter” key. The Command Line Interface (CLI) screen should
appear as below:
z Logon to Exec Mode (View Mode):
At the “switch_a login: prompt just type in “root” and press <Enter> to
logon to Exec Mode (or View Mode). And the “switch_a>” prompt will
show on the screen.
Hardened Managed Ethernet Switch
6 Users Manual
z Logon to Privileged Exec Mode (Enable Mode):
At the “switch_a>” prompt just type in “enable” and press <Enter> to
logon to Privileged Exec Mode (or Enable Mode). And the “switch_a#”
prompt will show on the screen.
z Logon to Configure Mode (Configure Terminal Mode):
At the “switch_a#” prompt just type in “configure terminal” and press
<Enter> to logon to Configure Mode (or Configure Terminal Mode). And
the “switch_a(config)#” prompt will show on the screen.
Web Configuration
z Login the switch:
Specify the default IP address (192.168.1.10) of the switch in the web
browser. A login window will be shown as below:
Hardened Managed Ethernet Switch
Users Manual 7
z Enter the factory default login ID: root.
Enter the factory default password (no password).
Then click on the “Login” button to log on to the switch.
Hardened Managed Ethernet Switch
8 Users Manual
Hardened Managed Ethernet Switch
Users Manual 9
Preface
This manual describes how to install and use the Hardened
Managed Ethernet Switch. This switch introduced here is
designed to deliver full scalability with SNMP/RMON
web-based management functions by providing:
To get the most out of this manual, you should have an
understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the Hardened Managed Ethernet Switch
z Illustrative LED functions
z Installation instructions
z Management Configuration
z SNMP, DHCP, IGMP…
z Specifications
Hardened Managed Ethernet Switch
10 Users Manual
Table of Contents
Quick Start Guide 1
PHYSICAL DESCRIPTION 1
The Port Status LEDs and Power Inputs 1
FUNCTIONAL DESCRIPTION 3
CONSOLE CONFIGURATION 5
WEB CONFIGURATION 6
Preface 9
Table of Contents 10
Product Overview 12
HARDENED MANAGED ETHERNET SWITCH 12
PACKAGE CONTENTS 12
PRODUCT HIGHLIGHTS 14
Basic Features 14
Management Support 15
FRONT PANEL DISPLAY 17
PHYSICAL PORTS 18
SWITCH MANAGEMENT 19
Web-based browser interface 19
Administration console via RS-232 serial port (CLI) 19
External SNMP-based network management application 19
Installation 20
SELECTING A SITE FOR THE SWITCH 20
WIRING DIAGRAM 21
CONNECTING TO POWER 21
12VDC DC Jack 21
Redundant DC Terminal Block Power Inputs 22
Alarms for Power Failure 22
CONNECTING TO YOUR NETWORK 23
Cable Type & Length 23
Cabling 23
Switch Management 25
MANAGEMENT ACCESS OVERVIEW 25
ADMINISTRATION CONSOLE (CLI) 26
Direct Access 26
Modem Access 27
WEB MANAGEMENT 27
SNMP-BASED NETWORK MANAGEMENT 27
PROTOCOLS 28
MANAGEMENT ARCHITECTURE 28
Web-Based Browser Management 29
Hardened Managed Ethernet Switch
Users Manual 11
SNMP & RMON Management 30
OVERVIEW 30
SNMP AGENT AND MIB-2 (RFC 1213) 30
RMON MIB (RFC 2819) AND BRIDGE MIB (RFC 1493) 31
RMON Groups Supported 31
Bridge Groups Supported 32
Web-Based Browser Management 33
LOGGING ON TO THE SWITCH 33
UNDERSTANDING THE BROWSER INTERFACE 35
SYSTEM 37
PORT 49
SWITCHING 54
TRUNKING 58
STP / RING 59
VLAN 68
QOS 75
SNMP 78
802.1X 84
OTHER PROTOCOLS 89
Command Line Console Management 95
ADMINISTRATION CONSOLE 95
Exec Mode (View Mode) 96
Privileged Exec Mode (Enable Mode) 100
Configure Mode (Configure Terminal Mode) 104
SYSTEM 108
PORT 116
SWITCHING 121
TRUNKING 126
STP / RING 127
VLAN 141
QOS 147
SNMP 150
802.1X 159
OTHER PROTOCOLS 164
Specifications 175
Appendix A 177
Appendix B 178
Hardened Managed Ethernet Switch
12 Users Manual
Product Overview
Hardened Managed Ethernet Switch
Front and Bottom View
Package Contents
When you unpack the product package, you shall find the
items listed below. Please inspect the contents, and report
Hardened Managed Ethernet Switch
Users Manual 13
any apparent damage or missing items immediately to your
rnet Switch
Manual
RS232 cable
authorized reseller.
The Hardened Managed Ethe
User’s
Hardened Managed Ethernet Switch
14 Users Manual
Product Highlights
Basic Features
z Meets NEMA TS1/TS2 Environmental requirements such as
temperature, shock, and vibration for traffic control equipment.
z Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity
for industrial environment.
z Manageable via SNMP, Web-based, Telnet, and RS-232 console port.
z Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
1000Mbps-full-duplex; 10/100Mbps-full/half-duplex; Auto MDI/MDIX.
z 100Base-FX: Multi mode SC or ST type; Single mode SC or ST type;
WDM Single mode SC type.
z 1000Base-SX/LX: Multi mode SC type, Single mode SC type, or WDM
Single mode SC type.
z Supports 8192 MAC addresses. Provides 2M bits memory buffer.
z Store-and-forward mechanism.
z Full wire-speed forwarding rate.
z Alarms for power and port link failure by relay output.
z Power Supply: Redundant DC Terminal Block power inputs and
12VDC DC JACK with 100-240VAC external power supply. "For Use
with Model UP0351E-12P as power jack supply source by Universal
Micro Electronics Co., Ltd.".
z Field Wiring Terminal: Use Copper Conductors Only, 60/75, 14-24
AWG torque value 4.5 lb-in.
z Operating voltage and Max. current consumption: 1.25A @ 12VDC,
0.625A @ 24VDC, 0.313A @ 48VDC. Power consumption: 15W Max.
z -40 to 75 (-40 to 167) operating temperature range. Tested for
functional operation @ -40 to 85 (-40 to 185). UL508
Industrial Control Equipment certified Maximum Surrounding Air
Temperature @ 75 (167).
z For use in Pollution Degree 2 Environment.
z Supports DIN-Rail and Panel Mounting installation.
z Suitable for use in Class I, Division 2, Groups A, B, C and D hazardous
locations, or nonhazardous locations only.
z WARNING – EXPLOSION HAZARD – Do not disconnect equipment
while the circuit is live or unless the area is known to be free of
ignitable concentrations.
Hardened Managed Ethernet Switch
Users Manual 15
z WARNING – EXPLOSION HAZARD – Substitution of any component
may impair suitability for Class I, Division 2.
z WARNING – Exposure to some chemicals may degrade the sealing
properties of materials used in the Sealed Relay Device.
z RECOMMENDATION - It is recommended to inspect the sealed relay
device periodically and to check for any degradation of the materials
and to replace the complete product, not the sealed device, if any
degradation is found.
z Sealed Relay Device information: Sealed Device: Relay Type
V23079-A2008-B301, manufactured by Tyco Electronics Logistics Ag.
Relay Cover: Manufacture of Plastic Material – Ticona.
Designation of Plastic Material – Vectra A130.
Relay Epoxy: Manufacture of Material – Guangzhou Wells
Chemical Co. Ltd. Designation of Material – Type 6060RP.
Generic Name of Plastic Material – Epoxy Resin.
Management Support
VLAN
z Port-based VLAN
z IEEE802.1Q tagged VLAN
TRUNKING
z MAC-based Trunking with automatic link fail-over
PORT-SECURITY
z Per-port programmable MAC address locking
z Up to 24 Static Secure MAC addresses per port
z IEEE802.1x Port-based Network Access Control
PORT-MIRRORING
z Port-mirroring
QOS (IEEE802.1p Quality of Service)
z 4 priority queues
INTERNETWORKING PROTOCOLS
z Bridging:
IEEE802.1s Multiple Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1D Spanning Tree compatible
IEEE802.1Q – GVRP
Ring
z IP Multicast:
Hardened Managed Ethernet Switch
16 Users Manual
IGMP Snooping
z Rate Control
z NTP
NETWORK MANAGEMENT METHODS
z Console port access via RS-232 cable (CLI, Command Line Interface)
z Telnet remote access
z SNMP agent:
MIB-2 (RFC1213)
Bridge MIB (RFC1493)
RMON MIB (RFC2819) – statistics, history, alarm and events
VLAN MIB (IEEE802.1Q/RFC2674)
Private MIB
z Web browser
z TFTP software-upgrade capability
Hardened Managed Ethernet Switch
Users Manual 17
Front Panel Display
z POWER
This LED comes on when the switch is properly connected to power and
turned on.
z Port Status LEDs
The LEDs are located on the front panel, displaying status for each
respective port. Please refer to the following table for more details.
Hardened Managed Ethernet Switch
18 Users Manual
LED State Indication
Steady Power on Power 1
Power 2
Power 3 Off Power off
10/100Base-TX, 100Base-FX
Steady A valid network connection established
Link/ACT
Flashing Transmitting or receiving data
ACT stands for ACTIVITY
10/100/1000Base-TX (Green), 100Base-FX (Orange)
Steady A valid network connection established
Link/ACT
Flashing Transmitting or receiving data
ACT stands for ACTIVITY
Physical Ports
The Hardened Managed Ethernet Switch provides:
16-port 10/100Base-TX (100Base-FX) + 2-port combo Gigabit
Hardened Managed Ethernet Switch
CONNECTIVITY
z RJ-45 connectors on TX ports
z ST or SC connector on 100Base-FX fiber port
z SC connector on 1000Base-SX/LX fiber port
MODE SELECTION
z 10Base-T full-duplex mode
z 10Base-T half-duplex mode
z 100Base-TX full-duplex mode
z 100Base-TX half-duplex mode
z 100Base-FX full-duplex mode
z 1000Base-T/SX/LX full-duplex mode
z Auto-negotiating mode
Hardened Managed Ethernet Switch
Users Manual 19
Switch Management
Web-based browser interface
The switch also boasts a point-and-click browser-based interface that
lets user access full switch configuration and functionality from a
Netscape or Internet Explorer browser.
Administration console via RS-232 serial port (CLI)
The switch provides an onboard serial port, which allows the switch to be
configured via a directly connected terminal.
External SNMP-based network management
application
The switch can also be configured via SNMP.
Hardened Managed Ethernet Switch
20 Users Manual
Installation
This chapter gives step-by-step instructions about how to
install the switch:
Selecting a Site for the Switch
As with any electric device, you should place the switch
where it will not be subjected to extreme temperatures,
humidity, or electromagnetic interference. Specifically, the
site you select should meet the following requirements:
-The ambient temperature should be between -40°C to 75 (-40 to
167).
-The relative humidity should be less than 95 percent, non-condensing.
-Surrounding electrical devices should not exceed the electromagnetic field
(RFC) standards.
-Make sure that the switch receives adequate ventilation. Do not block the
ventilation holes on each side of the switch.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184

Lacon L-EX73000 Quick start guide

Category
Network switches
Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI