HP 6Gb User manual

Category
Software
Type
User manual
HP 6G Virtual SAS Manager User Guide
Abstract
This guide provides information about using the HP Virtual SAS Manager application to configure and manage device zoning
through HP 6Gb SAS BL switches. Both the Graphical User Interface (GUI) and Command Line Interface (CLI) are detailed.
HP Part Number: 634040-002
Published: September 2011
Edition: 2
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial
Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under
vendor's standard commercial license.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Acknowledgements
Microsoft®, Windows®, Windows® XP, Windows® NT, Windows® Vista, Windows® 7, Windows® 2003, and Windows® 2008 are U.S.
registered trademarks of Microsoft Corporation.
Revision History
September 2011Revision #2
Added support for zoned SAS storage enclosures and some additional new features and enhancements
April 2011Revision # 1
Initial publication
Contents
I Basic information and concepts.....................................................................6
1 About this document and 6G solutions......................................................8
About this document.............................................................................................................8
About solutions using the HP 6Gb SAS BL Switch.....................................................................8
2 Zone group concepts and device mappings...............................................9
Zone group concepts............................................................................................................9
Device mappings.................................................................................................................9
II VSM GUI.................................................................................................11
3 Getting started.....................................................................................14
Accessing the VSM GUI.....................................................................................................14
Page description................................................................................................................15
System status information....................................................................................................16
Switch status states........................................................................................................16
Online help.......................................................................................................................17
Performing tasks.................................................................................................................17
Configuring the switch (key steps).........................................................................................17
Configuring P2000 G3 SAS MSA shared SAS storage enclosures (overview).............................19
Configuring MDS600 or D2600/D2700 zoned SAS storage enclosures (overview)....................20
4 Tasks in the VSM Zoning tab..................................................................21
More Information task.........................................................................................................22
Topology Map task............................................................................................................22
Create Zone Group task.....................................................................................................23
Creating switch-port zone groups....................................................................................23
Creating drive-bay zone groups......................................................................................25
Delete Zone Groups task.....................................................................................................26
Delete task........................................................................................................................27
Modify task.......................................................................................................................27
Clear Configuration task.....................................................................................................28
Advanced Settings task.......................................................................................................28
Split Port task....................................................................................................................29
Merge Sub-Ports task..........................................................................................................29
Create Single Port Zone Group task......................................................................................29
Replicate Zoning Configuration task.....................................................................................30
Modify Zone Access task....................................................................................................30
Create and Assign Zone Group task.....................................................................................31
Creating and assigning switch-port zone groups................................................................31
Creating and assigning drive-bay zone groups.................................................................33
5 Tasks in the VSM Maintain tab...............................................................35
Capture Configuration task..................................................................................................36
Input Configuration task......................................................................................................36
Update SAS Switch Firmware task........................................................................................36
Prerequisites.................................................................................................................36
Obtaining new firmware................................................................................................37
Updating HP 6Gb SAS BL Switch firmware in single-domain deployments.............................38
Updating HP 6Gb SAS BL Switch firmware in dual-domain deployments...............................39
Reset Hardware task...........................................................................................................41
Reset Software task............................................................................................................41
Update Storage Enclosure Firmware task...............................................................................41
Contents 3
Prerequisites.................................................................................................................42
Obtaining new firmware................................................................................................42
Procedures...................................................................................................................43
Reset Storage Enclosure task................................................................................................44
Network Settings task.........................................................................................................45
SNMP Settings task............................................................................................................45
SNMP Test Trap task..........................................................................................................45
Force VSM Active task........................................................................................................46
VSM Event Log task............................................................................................................46
Clear VSM Event Log task...................................................................................................47
Diagnostic Log task............................................................................................................47
Unit ID Light task................................................................................................................47
Replicate Zoning Configuration task.....................................................................................47
6 Troubleshooting....................................................................................49
Moving zone groups..........................................................................................................49
Moving zone groups—zoned SAS storage enclosures........................................................49
Moving zone groups—shared SAS storage enclosures........................................................50
III VSM CLI.................................................................................................51
7 Getting started.....................................................................................53
Accessing the VSM CLI.......................................................................................................53
Command syntax...............................................................................................................55
Example command........................................................................................................55
Target overview............................................................................................................55
Command listing...........................................................................................................56
Parameter overview.......................................................................................................57
Executing commands..........................................................................................................58
Keyboard shortcuts and keyword abbreviations.................................................................58
8 Getting help........................................................................................59
The help command............................................................................................................59
The show command...........................................................................................................60
9 Performing common tasks......................................................................62
Enabling or disabling multi-initiator mode and port splitting.....................................................63
Creating zone groups.........................................................................................................64
Creating a switch-port zone group...................................................................................65
Creating a drive-bay zone group.....................................................................................67
Assigning a zone group to a server device bay......................................................................69
Capturing the configuration.................................................................................................71
Inputting or restoring the configuration..................................................................................72
Flashing switch firmware.....................................................................................................73
Flashing storage enclosure firmware.....................................................................................75
Resetting the VSM software, the switch or attached storage enclosures......................................76
10 Creating and executing CLI scripts.........................................................77
IV Support and other resources.....................................................................78
11 Support and other resources.................................................................80
Contacting HP...................................................................................................................80
Subscription service.......................................................................................................80
Related information............................................................................................................80
HP websites..................................................................................................................80
Prerequisites......................................................................................................................81
Typographic conventions.....................................................................................................81
4 Contents
HP product documentation survey........................................................................................82
Index.........................................................................................................83
Contents 5
Part I Basic information and concepts
HP Virtual SAS Manager (VSM) is the software application used to configure HP SAS BL Switches, including
tasks such as creating and managing hardware-based zone groups. These zone groups allocate resources
for device load balancing purposes and for selectively allowing access to data. For planning purposes,
zone groups and assignments can be pre-configured, even if server bays or drive bays are not yet populated.
Embedded in the SAS BL Switch firmware, VSM can be deployed in two operating modes: a graphical user
interface (GUI) and a command line interface (CLI).
Graphical User Interface (GUI)—For information on the VSM GUI, see “VSM GUI” (page 11).
Command Line Interface (CLI)—For information on the VSM CLI, see “VSM CLI” (page 51).
Contents
1 About this document and 6G solutions..........................................................8
About this document.................................................................................................................8
About solutions using the HP 6Gb SAS BL Switch..........................................................................8
2 Zone group concepts and device mappings...................................................9
Zone group concepts................................................................................................................9
Device mappings......................................................................................................................9
Contents 7
1 About this document and 6G solutions
About this document
This document assumes that all associated devices are physically installed and all required
software components are installed on the servers. For hardware compatibility information,
supported operating system versions, and supported Internet browser versions, see the SAS
switch QuickSpecs. Review the QuickSpecs and verify that supported versions are installed
on the devices.
Examples in this document use dual HP 6Gb BL Switches installed in an HP BladeSystem
c7000 enclosure.
For information about installing and cabling the switch, see the following user documents,
available on the 6Gb SAS BL Switch page of the HP Manuals website http://www.hp.com/
support/manuals:
HP 6Gb SAS BL Installation Instructions
HP 6Gb SAS BL User Guide
HP BladeSystem Deployment Guide for Solutions with 6Gb SAS BL Switches and External
SAS Storage Enclosures
Information is located as follows in this guide:
Example procedures: “Configuring P2000 G3 SAS MSA shared SAS storage enclosures
(overview)” (page 19).
Example procedures: “Configuring MDS600 or D2600/D2700 zoned SAS storage
enclosures (overview)” (page 20).
Field details: “Tasks in the VSM Zoning tab” (page 21)
Field details: “Tasks in the VSM Maintain tab” (page 35)
About solutions using the HP 6Gb SAS BL Switch
In dual-domain environments with two switches installed in the same interconnect bay row of
the HP BladeSystem c-Class enclosure, both switches can process I/O, but the VSM utility can
be active on only one of the switches. Switch status (Active or Passive) is shown in the VSM
navigation tree. If you log in to the switch with the passive VSM and want to make any zoning
configuration changes, you must exit VSM for that switch and log back in to the switch with
the active VSM.
Zoning is created and managed through the VSM, but the storage is configured, formatted,
and partitioned using software utilities such as the HP Array Configuration Utility (ACU), HP
Storage Management Utility (SMU), and Microsoft Disk Manager.
8 About this document and 6G solutions
2 Zone group concepts and device mappings
Zone group concepts
Zone groups allocate resources for device load balancing purposes and for selectively allowing
access to data. For planning purposes, zone groups and assignments can be pre-configured, even
if servers or disk drives are not yet installed.
Types of zone groups:
Switch port zone groups—Group together one or more ports on the SAS BL Switch. Server
device bays assigned this type of zone group have access to the storage enclosures or tape
devices connected to the ports included in the zone. This type of zone group is for shared
SAS devices. The P2000 G3 SAS MSA and HP MSL2024, MSL4048, and MSL8096 Tape
Libraries and 1/8 G2 Tape Autoloader are examples of shared SAS devices. All LUNs in the
controller enclosure are accessible to the assigned servers, unless controlled through the storage
management utility for the controller enclosure and all tape drives in a tape device are
accessible to any server that has access to the zone group.
Drive bay zone groups—Group together drive bays from one or more MDS600 drawers or
D2000 disk enclosures. Server device bays assigned this type of zone group have exclusive
access to the drive bays included in the zone group, as if the drives are directly connected to
those servers. This type of zone group is for zoned SAS storage enclosures. The MDS600 and
D2600/D2700 enclosures are examples of zoned SAS storage.
As shown in the following table, configuration (zoning type) procedures are the same for shared
SAS storage enclosures and tape devices, but differ for zoned SAS storage enclosures:
Zoning typeType of connected external device
Switch portShared SAS storage enclosures (P2000 G3 SAS MSA)
Drive bayZoned SAS storage enclosures (MDS600 and D2600/D2700)
Switch portTape devices
Device mappings
IMPORTANT: Depending on the BladeSystem c-Class enclosure model, server type, mezzanine
slot used, and BladeSystem server device bay, the SAS BL Switch must be installed in specific
BladeSystem interconnect bay row. The following tables show the interdependencies of components
in an HP BladeSystem c-Class solution that includes SAS BL Switch connected to external SAS
storage enclosures.
Device mappings for the c3000 BladeSystem enclosure:
BladeSystem c-Class
nl
interconnect bay
Mezzanine slotServer typeBladeSystem c-Class
nl
enclosure model
3/4
2Half height
c3000
2
Full height
3
2
Full height
nl
Double wide
nl
3
(BL680c G7)
4
7
Zone group concepts 9
Device mappings for the c7000 BladeSystem enclosure:
BladeSystem c-Class
nl
interconnect bay
Mezzanine slotServer typeBladeSystem c-Class
nl
enclosure model
3/41
Half height
c7000
5/6/7/82
3/41
Full height 5/6/7/82
5/6/7/83
3/41
Full height
nl
Double wide
nl
5/6/7/82
(BL680c G7)
5/6/7/83
5/6/7/84
3/45
5/6/7/87
10 Zone group concepts and device mappings
Part II VSM GUI
Contents
3 Getting started.........................................................................................14
Accessing the VSM GUI..........................................................................................................14
Page description.....................................................................................................................15
System status information.........................................................................................................16
Switch status states.............................................................................................................16
Online help...........................................................................................................................17
Performing tasks.....................................................................................................................17
Configuring the switch (key steps).............................................................................................17
Configuring P2000 G3 SAS MSA shared SAS storage enclosures (overview)..................................19
Configuring MDS600 or D2600/D2700 zoned SAS storage enclosures (overview).........................20
4 Tasks in the VSM Zoning tab......................................................................21
More Information task.............................................................................................................22
Topology Map task.................................................................................................................22
Create Zone Group task..........................................................................................................23
Creating switch-port zone groups.........................................................................................23
Creating drive-bay zone groups...........................................................................................25
Delete Zone Groups task.........................................................................................................26
Delete task.............................................................................................................................27
Modify task...........................................................................................................................27
Clear Configuration task..........................................................................................................28
Advanced Settings task...........................................................................................................28
Split Port task.........................................................................................................................29
Merge Sub-Ports task...............................................................................................................29
Create Single Port Zone Group task..........................................................................................29
Replicate Zoning Configuration task..........................................................................................30
Modify Zone Access task.........................................................................................................30
Create and Assign Zone Group task.........................................................................................31
Creating and assigning switch-port zone groups....................................................................31
Creating and assigning drive-bay zone groups......................................................................33
5 Tasks in the VSM Maintain tab...................................................................35
Capture Configuration task......................................................................................................36
Input Configuration task...........................................................................................................36
Update SAS Switch Firmware task.............................................................................................36
Prerequisites......................................................................................................................36
Obtaining new firmware.....................................................................................................37
Updating HP 6Gb SAS BL Switch firmware in single-domain deployments.................................38
Updating HP 6Gb SAS BL Switch firmware in dual-domain deployments...................................39
Reset Hardware task...............................................................................................................41
Reset Software task.................................................................................................................41
Update Storage Enclosure Firmware task....................................................................................41
Prerequisites......................................................................................................................42
Obtaining new firmware.....................................................................................................42
Procedures........................................................................................................................43
Reset Storage Enclosure task....................................................................................................44
Network Settings task..............................................................................................................45
SNMP Settings task.................................................................................................................45
SNMP Test Trap task...............................................................................................................45
Force VSM Active task.............................................................................................................46
VSM Event Log task................................................................................................................46
Clear VSM Event Log task........................................................................................................47
12 Contents
Diagnostic Log task.................................................................................................................47
Unit ID Light task....................................................................................................................47
Replicate Zoning Configuration task..........................................................................................47
6 Troubleshooting........................................................................................49
Moving zone groups...............................................................................................................49
Moving zone groups—zoned SAS storage enclosures.............................................................49
Moving zone groups—shared SAS storage enclosures............................................................50
Contents 13
3 Getting started
Accessing the VSM GUI
VSM is accessed through the Onboard Administrator (OA) application of the BladeSystem c-Class
enclosure in which the switch is installed. (For the minimum supported OA version, see the 6Gb
SAS BL Switch QuickSpecs.)
NOTE: To navigate directly to the VSM for a SAS switch, open the browser and enter the OA
IP address or hostname followed by the interconnect variable. For example:
https://10.10.1.254/interconnectX/ or https://hostname/interconnectX/,
where X specifies the interconnect bay number.
1. Install and connect the HP BladeSystem c-Class enclosure and the servers, controllers, switches,
external storage enclosures, and other devices associated with your BladeSystem c-Class
enclosure solution. These procedures are detailed in the user documents for each device.
For hardware compatibility information, supported operating system versions, and supported
Internet browser versions, see the SAS BL Switch QuickSpecs. Review the QuickSpecs and
verify that supported versions are installed on the devices.
2. Log in to Onboard Administrator for the BladeSystem c-Class enclosure.
a. Obtain and record the IP address or hostname assigned to the BladeSystem c-Class
enclosure OA module. (The IP address or hostname may be recorded on worksheets
provided with your system installation instructions.)
b. From a server or workstation with access to the system, open a browser and enter the
OA address or hostname.
For example: https://10.10.1.254 or https://hostname
c. Enter an OA username and password with administrative privileges, and then wait a few
moments for OA to open.
3. In the OA Systems and Devices tree, expand Interconnect Bays, select the HP 6Gb SAS BL
Switch to manage, and click Management Console.
After a few moments, the VSM GUI is displayed.
14 Getting started
NOTE: In dual-domain switch configurations with two switches in the same interconnect bay row
of the HP BladeSystem c-Class enclosure, both switches can process I/O, but the VSM utility can
be active on only one of the switches. Switch management status (Active or Passive) is shown in
the VSM navigation tree (not the OA navigation tree). If you log in to the switch with the passive
VSM and want to make any zoning configuration changes, you must exit VSM for that switch and
log back in to the switch with the active VSM.
Page description
Each time the VSM is accessed, the “VSM Overview” page opens automatically, displaying a brief
summary about the SAS BL switches, zone groups, blade ports (server bays), and storage enclosures
included in the solution.
The VSM GUI page is divided as follows:
5. VSM firmware version1. Zoning and Maintain tabs
6. Task selection buttons and data input fields2. System status summary
7. VSM CLI IP address3. Systems and devices navigation tree
4. VSM GUI URL (OA IP address with c-Class enclosure interconnect bay number appended)
Page description 15
System status information
A summary of system status information is displayed in the System Status section of the page.
Critical—System is not operating properly
Warning—Service is needed
Informational—Helpful information
Status alert details may be viewed in the following different ways:
To view all status messages: In the System Status section near the top-left of the VSM page,
click View Status Alerts.
To view status messages for a specific device: In the navigation tree, select the device, and
then click View Status Alerts.
To view a specific message: Click the icon or message, whether it is in the navigation tree,
an informational display, or elsewhere.
Included in the System Status section of the VSM display, the Refresh option updates the information
in the navigation tree.
NOTE: If a hardware change has been made since the Systems and Devices navigation tree was
last refreshed, a notification message is displayed within this System Status section. When this
message is displayed, click Refresh to update the display.
Switch status states
Next to each switch in the Systems And Devices navigation tree, one of the following status values
may be displayed:
Degraded Displayed in dual-domain switch deployments. The partner switch is present
but is not communicating. For example, if one switch experiences a failure,
the status of the still-functioning partner switch may be Degraded.
Mismatch Displayed in dual-domain switch deployments, this is displayed when the
system detects different firmware versions installed on the paired switches.
This is also displayed when data such as zone records, enclosure serial
number, or bay number do not match.
Not Configured Displayed in single-switch deployments. This is displayed next to a
newly-installed switch.
Not Redundant Displayed in single-switch deployments. The switch is fully operational and
Active. For example, if one switch experiences a failure, the status of the
still-functioning partner switch may be Not Redundant.
Unknown Displayed in both single-switch and dual-domain switch deployments. This
is displayed when the current state can not be determined.
VSM Active Displayed in dual-domain switch deployments. The switch is fully operational
and Active.
VSM Passive Displayed in dual-domain switch deployments. This is displayed next to
one of the switches in a pair, while the VSM Active is displayed next to the
partner switch. This switch may automatically become VSM Degraded or
Not Redundant if the partner switch experiences a failure.
16 Getting started
Online help
Extensive online help is available. At any time, click the Help icon in the top right of the page. The
following image is an example display of the online help.
Performing tasks
To perform any task in the VSM, observe the following key steps:
1. Select a tab at the top-left of the page.
2. Select a system component in the navigation tree on the left side of the page.
3. Select a task from the list on the right side of the page.
NOTE: If a task is listed, but cannot be selected, system status conditions are not acceptable
for that task to be performed. When this occurs, the cause is listed, so corrective action can
be taken.
4. Enter the requested information.
5. Click Save Changes.
Configuring the switch (key steps)
After physically installing the switch (or switches) in the BladeSystem c-Class enclosure and cabling
them to external SAS storage enclosures, do the following to configure the switches and the storage:
1. Go to the Maintain tab to configure switch parameters. Key tasks include:
a. Enter network settings.
b. Enter SNMP settings.
c. Update switch firmware (if needed).
d. Update storage enclosure firmware (if needed).
Online help 17
2. Go to the Zoning tab to create and assign zone groups. Key tasks include:
a. Set the multi-initiator mode and, if multiple tape devices are included in the solution,
enable port-splitting mode (optional).
b. Create the zone groups.
For deployments with shared SAS storage enclosures and tape libraries, create
switch-port zone groups.
For deployments with zoned SAS storage enclosures, create drive-bay zone groups.
c. Assign zone groups to servers.
3. Go to the Maintain tab to capture the configuration for safekeeping. HP strongly recommends
this step, especially in single-domain configurations.
Configuration information is located as follows in this guide:
Example procedures: “Configuring P2000 G3 SAS MSA shared SAS storage enclosures
(overview)” (page 19).
Example procedures: “Configuring MDS600 or D2600/D2700 zoned SAS storage enclosures
(overview)” (page 20).
Field details: “Tasks in the VSM Zoning tab” (page 21)
Field details: “Tasks in the VSM Maintain tab” (page 35)
18 Getting started
Configuring P2000 G3 SAS MSA shared SAS storage enclosures
(overview)
Configuring shared SAS storage enclosures includes the following tasks, performed in sequence:
1. Enable Multi-initiator Mode. (Advanced Settings task” (page 28))
2. Optional: Enable Port-splitting Mode if multiple tape autoloaders or libraries are included in
the solution. (Advanced Settings task” (page 28))
3. Create one or more switch-port zone groups. (Create Zone Group task” (page 23))
Unused switch ports can be included in a zone group.
Until a server device bay is assigned a zone group, it cannot access the storage.
4. Assign each zone group to each server device bay that needs access to the storage enclosures
associated with that zone group. (Modify Zone Access task” (page 30))
All available zone groups are displayed.
After a zone group has been assigned to a server device bay, its status changes from
unassigned” to “assigned”.
5. Capture the configuration for safekeeping. Capture Configuration task” (page 36))
6. Configure disk drives in the storage enclosure into logical storage units (LUNs) using the
management utility supported by the storage enclosure. Access to the LUNs is controlled
through mappings or other presentation methods, which grant specific server device bays to
specific LUNs.
Helpful hints
The HP P2000 G3 SAS MSA Array is an example of a shared SAS storage enclosure.
The shared SAS storage enclosure includes a RAID array controller. A RAID controller is
installed on the server, but not used for its RAID configuration capabilities.
Use switch-port zone groups with shared SAS storage enclosures. The entire storage enclosure
connected to that switch port is visible to all server device bays granted access to the zone
group that includes that switch port.
Each server device bay that needs access to the external storage must be assigned a zone
group.
A server device bay can be assigned multiple zone groups.
A switch-port zone group can be assigned to more than one server device bay.
Unpopulated server device bays can be assigned a zone group.
Disks in the enclosure are configured into logical storage units (LUNs) using one of the servers
(or a designated management server) with access to the storage enclosure. Access to the LUNs
is controlled through mappings or other presentation methods, which grant specific server
device bays to specific LUNs.
Configuring P2000 G3 SAS MSA shared SAS storage enclosures (overview) 19
Configuring MDS600 or D2600/D2700 zoned SAS storage enclosures
(overview)
Configuring zoned SAS storage enclosure includes the following tasks, performed in sequence:
1. Disable Multi-initiator Mode. (Advanced Settings task” (page 28))
NOTE: If tape autoloaders/libraries or shared SAS storage enclosures are also connected
to the switch and multiple server device bays will need access to the same switch-port zone
groups, Multi-initiator Mode must be Enabled.
2. Optional: Enable Port-splitting Mode if multiple tape autoloaders or libraries are included in
the solution. (Advanced Settings task” (page 28))
3. Create one or more drive-bay zone groups. (Create Zone Group task” (page 23))
Unpopulated drive bays can be included in a zone group.
Until a server device bay is assigned a zone group, it cannot access the storage.
4. Assign each zone group to the device server bay that needs access to the storage associated
with that zone group. (Modify Zone Access task” (page 30))
If the Multi-initiator mode is disabled, only unassigned (available) zone groups are
displayed; if a zone group has already been assigned to a server device bay, it is not
displayed.
After a zone group has been assigned to a server device bay, its status changes from
unassigned” to “assigned”.
5. Capture the configuration for safekeeping. Capture Configuration task” (page 36))
6. Configure disk drives in the storage enclosure into logical storage units (LUNs) using the
management utility supported by the storage enclosure.
Helpful hints
MDS600 and D2600/D2700 Disk Enclosures are examples of zoned SAS storage enclosures.
A RAID controller is installed in the server and is used for its RAID configuration capabilities.
The zoned SAS storage enclosure does not includes a RAID array controller.
Use drive-bay zone groups to configure zoned SAS enclosures, so that the group of drive bays
is presented to the server device bay as if it was directly connected to that server device bay.
Each server device bay that needs access to the external storage must be assigned a zone
group.
A server device bay can be assigned multiple zone groups.
A drive-bay zone group can be assigned to only one server device bay.
Unpopulated enclosure server device bays can be assigned zone groups.
The disks in the enclosure are configured into logical storage units (LUNs) using host based
configuration utilities (such as ACU or ACU CLI) running on the server with access to the zone
group containing the drive bays.
20 Getting started
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85

HP 6Gb User manual

Category
Software
Type
User manual

Ask a question and I''ll find the answer in the document