Tylö CC 100-0B Operating instructions

Type
Operating instructions

This manual is also suitable for

5
INSTRUCTIONS FOR USE
CC 10
10
9
8
7
6
5
4
3
2
1
1
2
3
5
4
Functions.
1 = setting scale. 2 = time settings. 3 = temperature settings. 4 = on. 5 = off.
Temperature setting.
(The heater must be switched on)
Press TEMP – the previous temperature setting is displayed.
The numbers indicate a rising temperature scale. Experiment to find the temperature
that suits you best. Begin for example by turning the thermostat dial to position 4. If you
later find that you would prefer a higher or lower temperature, adjust the dial up or down
until you find the ideal bathing temperature for you (usually 70-90°C (158-194°F) for
traditional dry and wet sauna baths, 40-45°C (104-113°F) for steam saunas and herb
saunas).
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. (the LED goes out).
A memory function automatically sets the previous temperature.
Press TEMP to change the pre-set temperature.
The built-in timer automatically switches the sauna heater/steam generator off after
3 hours. If you want to switch it off earlier than that, press OFF. To extend the sauna
time, press ON.
Timer settings.
(The heater must be switched off)
The numbers in this case represent the timer times (= the number of hours until the
heater automatically switches on). To set the timer:
Press TIME – use the arrow keys to select the desired pre-set time, 1–10 hours.
Press ON – the timer is activated and the time indicator blinks during the pre-set time
period. Once the heater switches itself on, it remains on for 3 hours, after which it
automatically switches itself off. If you want to switch it off earlier than that, just press
OFF. To extend your sauna time, press ON.
Main power switch.
To be changed more than once: At the bottom of the relay box, the SE unit and the
smaller types of steam generators is a main power switch that disconnects the heater
entirely from the electrical supply. This main switch should only be used if the sauna will
not be used for a longer period, such as several weeks. To be changed more than once:
The memory function must be reset each time the power is interrupted.
INSTRUCTIONS FOR USE
CC 50
00
1
2
3
4
6
Functions.
1 = lighting. 2 = on/off. 3 = temperature setting. 4 = time setting. 5 = reduce temperature/time.
6 = increase temperature/time. 7 = display.
Lighting.
Lights automatically when the facility starts and switches off automatically when the
facility shuts down. You can also switch the lighting on or off manually by pressing
LIGHT.
Main power switch.
To be changed more than once: At the bottom of the relay box, the SE unit and the
smaller types of steam generators is a main power switch that disconnects the heater
entirely from the electrical supply. This main switch should only be used if the sauna will
not be used for a longer period, such as several weeks. To be changed more than once:
The memory function must be reset each time the power is interrupted.
The thermometer in the sauna/steam bath should be placed at such a height that the
temperature corresponds exactly to the numbers in the panel of the CC 50.
SETTINGS
CC 50, all models
Setting the bathing temperature.
Press TEMP – the previous temperature is displayed. Use the up and down arrows (
) to change the temperature.
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. (the LED goes out). If
you forget to switch off the generator manually, it switches off automatically after 3 or 12
hours - depending on the type of control panel.
Timer settings.
(The sauna must be switched off)
Press TIME (the hour digits blink) – set the number of hours until you want to use the
sauna using the up and down arrows ( ).
Press TIME (the minute digits blink) – set the number of minutes until you want to use
the sauna using the up and down arrows ( ).
(Important: The hour or minute digits must be blinking before you press ON).
Press ON – the on time is activated and a red LED blinks until the sauna automatically
starts after the pre-set time. The heater switches off automatically after 3 or 12 hours
depending on the type of control panel.
You can switch off the sauna manually at any time by pressing OFF.
Changing the type of panel (Factory settings = Test no. 50),
1. Connect the voltage.
2. Press and at the same time for approx. 6 sek (max. 60 sek. after the
voltage is connected).
3. Change the type of panel according to the scheme with and , approve
with TEMP.
Panel type Test no.
*
Test no.
** Description
CC50-3B 50 50.A Sauna 110°C, 3 h running time
CC50-12B 51 51.A Sauna 110°C, 12 h running time
CC50-3S 53 53.A Steam 55°C, 3 h running time
CC50-12S 54 54.A Steam 55°C, 12 h running time
CC50-1S 15 15.A Steam 55°C, 1 h running time
CC50-1B 18 18.A Sauna 110°C, 1 h running time
CC50-24B 58 58.A Sauna 110°C, 24 h running time
CC50-0B 59 59.A Sauna 110°C, ON/OFF
CC50-24S 68 68.A Steam 55°C, 24 h running time
CC50-0S 69 69.A Steam 55°C, ON/OFF
* Settings at ev. use of extern switch with impulse function.
** Settings at ev. use of extern switch with ON/OFF function.
Code lock to prevent settings from being changed.
First program as ”Settings”, press on the down arrow ( ), hold it down and press TEMP
and TIME at the same time. The code lock, which prevents changing of settings, is now
activated. To return to unlocked mode, press the down arrow ( ), hold it down and
press OFF at the same time.
Code lock that prevents changing of the temperature setting.
First program as ”Settings”, press TIME, hold it down and press TEMP and LIGHT at
the same time. The code lock, which prevents changing of the temperature settings, is
now activated. To return to unlocked mode, press the down arrow ( ), hold it down and
press OFF at the same time.
6
INSTRUCTIONS FOR USE
CC 100
Functions.
1 = on, 2 = temperature settings, 3 = off, 4 = lighting, 5 = move left, 6 = reduce
temperature/time and move down, 7 = move right, 8 = increase temperature/time and
move up, 9 = settings menu, 10 = information menu, 11 = display.
12 = built-in, factory-set processor, can be customised as desired.
A simplified version of these instructions are found under INFO in CC 100.
CC 100 has a built-in power reserve and you can choose between 7 different
languages.
After each power failure, the model designation of the control panel is displayed
for five seconds.
Lighting.
Lights automatically when the facility starts and switches off automatically when the
facility shuts down. You can also switch the lighting on or off manually by pressing
LIGHT.
Password.
Prevents unauthorised changing of the settings.
Main power switch.
There is a main power switch on the bottom of the relay box, SE heater and the smaller
steam generators. You need only use this switch if the facility is to be switched off for a
long time.
The thermometer should be placed at such a height that the temperature corresponds
exactly to the numbers displayed on the CC 100.
Stand-by.
Stand-by is invaluable for saunas or steambaths in hotels, bath houses and so on, where
the frequency of use varies. During low-frequency periods, the facility is set on energy-
saving "stand-by", which can quickly accelerate to the desired bathing temperature
when you press ON. The stand-by function saves significant amounts of money each
year.
The examples below show how easy it is to programme a suitable bath schedule.
Stand-by examples:
Three different bath facilities are open between 8 a.m. and 8 p.m. The bathing
frequencies of the facilities varies like this:
Alt. 1) A small number of bathers come sporadically throughout the day. Programme
stand-by between 800 and 800 pm. The bathers (or bath attendant) activate the
programme by pressing the ON button on the CC panel, or by pressing on the separate,
external ON/OFF switch, if there is one.
Alt. 2) A small number of bathers come sporadically between 800 and 2 pm. After 2 pm,
there is a steady flow of guests until closing. Programme stand-by between 800 and 8
pm and programme a fixed ”ON” time between 2 pm and 8 pm. The sporadic bathers
activate the programme by pressing the ON button on the CC panel, or by pressing on
the separate, external ON/OFF switch, if there is one.
Alt. 3) A large number of bathers between 800 and 1000, 1 pm and 2 pm and 6 pm and 8
pm. The rest of the day, only sporadic bathers come. Programme stand-by between 800
and 8 pm, programme fixed ”ON” times for the steady bath times. The sporadic bathers
activate the programme by pressing the ON button on the CC panel, or by pressing on
the separate, external ON/OFF switch, if there is one.
SETTINGS
CC 100 all models
Note: for all settings, the Tylarium should be switched OFF.
Language.
Press MENU – Use the left and right arrow keys ( ) to move to choice of language.
Start programming mode by pressing the down arrow ( ).
Use the left and right arrow keys ( ) to select the language. Press the up arrow ( ) to
exit and press MENU to change language.
Time (clock).
Press MENU – Use the left and right arrow keys ( ) to move to clock settings. Start
programming mode by pressing the down arrow ( ).
Use the up and down arrow keys ( ) to set the day. Move to the hour setting by
pressing the right arrow ( ). Set the hour using the up and down arrows
( ), and shift to minutes with the right arrow ( ). Change the minutes using the up
and down arrows ( ).
Press MENU to exit. ( ).
SETTINGS
Note: CC 100-3B/3S/12B/12S only
Note: for all settings, the Tylarium should be switched OFF. To be changed
more than once: However, temperature and humidity settings can be changed
when the Tylarium is ON.
MANUAL ON/OFF.
Note: CC 100-3B/3S/12B/12S only
Setting the bathing temperature.
Press TEMP – the previous temperature is displayed. Use the up and down arrows (
) to change the temperature.
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. If you forget to switch it off
manually, the generator automatically switches off after 3 or 12 hours – depending on
the type of control panel.
AUTOMATIC ON/OFF.
Note: CC 100-3B/3S/12B/12S only
Setting on/off and temperature.
Press MENU – Use the left and right arrow keys ( ) to move to timer settings. Use
the down arrow ( ) to start programming mode.
Use the up and down arrows ( ) to set the start to set the start hour, then shift to
minutes with the right arrow ( ). Change the minutes using the up and down arrows
( ).
Use the right arrow ( ) to move to the end hour setting and then the up and down
arrows ( ) to set the end hour. Shift to minutes with the right arrow ( ) to set the
end time, Change the minutes using the up and down arrows
( ). Use the right arrow ( ) to shift to temperature. Change the temperature using
the up and down arrows ( ). Shift to on/off with the right arrow ( ). Change the
on/off mode using the up and down arrows ( ).
Now the setting is programmed and a red LED blinks until the sauna or steam bath
starts at the time set. After this, it glows steadily (a text on the display tells when this
happens). The sauna switches off automatically 3 or 12 hours after the pre-set time
depending on the type of control panel.
To be changed more than once: You can switch off your sauna or steam bath manually
at any time by pressing OFF. To restart with the same settings, press MENU – Use the
right and left arrows ( ) to go to timer settings. Start programming mode by
pressing the down arrow ( ), shift to on/off with the right arrow ( ). Change the on/off
mode using the up and down arrows ( ).
STAND-BY programming.
Note: CC 100-3B/3S/12B/12S only
Press MENU – Use the right and left arrows ( ) to go to stand-by setting. Start
programming mode by pressing the down arrow ( ).
Use the up and down arrows ( ) to set the start hour, then shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows
( ).
To be changed more than once: Use the right arrow ( ) to move to end hour setting
and then the up and down arrows ( ) to set the end hour. Shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows ( ). Use the
right arrow ( ) to shift to temperature. Change the temperature using the up and down
arrows ( ). Shift to on/off with the right arrow ( ). Change the on/off mode using the
up and down arrows ( ).
Now the stand-by is programmed and a red LED blinks until the sauna or steam bath
starts at the time set. After this, it glows steadily (a text on the display shows that the
panel is in a stand-by position and when it will switch on).
As soon as you press ON, the temperature increases to the pre-set bathing
temperature. After 1 hour, the facility automatically resumes stand-by temperature.
Each time you press ON, 1 hour’s bathing time begins.
Note: if both the timer time and stand-by time are set to be on at the same time, the
timer function takes over.
To be changed more than once: You can switch off your sauna or steam bath manually
at any time by pressing OFF. To restart with the same settings, press MENU – Use the
right and left arrows ( ) to go to stand-by. Start programming mode by pressing the
down arrow ( ), shift to on/off with the right arrow ( ). Change the on/off mode using
the up and down arrows ( ).
Password
Note: CC 100-3B/3S/12B/12S only
Setting the password.
Press MENU – Use the right and left arrows ( ) to go to password setting. Start
programming mode by pressing the down arrow ( ). Enter the code using all the arrow
keys ( ).(After power failure, the code is reset to 1995). Press MENU, use the
left arrow key ( ) to change the code. Set the new code using all the arrow keys (
). Press MENU. Activate on/off with the right arrow ( ), press MENU. Now the
password is activated.
To return to unlocked mode, repeat the above procedure but set on/off to off.
Note: Do all other settings before setting the password.
1
2
3
4
5
6
1
0
1
1
1
2
9
M
o
n
d
a
y
1
0
:
0
0
:
0
0
C
C
1
0
0
i
s
o
f
f
P
r
e
s
s
O
N
t
o
s
t
a
r
t
P
r
e
s
s
I
N
F
O
f
o
r
h
e
l
p
7
SETTINGS
Note: CC 100-0B/0S only
Note: for all settings, the Tylarium should be switched OFF. To be changed
more than once: However, temperature and humidity settings can be changed
when the Tylarium is ON.
MANUAL ON/OFF.
Note: CC 100-0B/0S only
Setting the bathing temperature.
Press TEMP – the previous temperature is displayed. Use the up and down arrows (
) to change the temperature.
Manual on/off.
Important! Don’t forget to set the off time. The sauna may be switched on for a
maximum of 12 hours.
Press ON to switch the facility on. Press OFF to switch it off.
PROGRAMMING THE WEEKLY TIMER
with different settings for different days of the week.
Note: CC 100-0B/0S only
Setting on/off, temperature.
Press MENU – Use the left and right arrow keys ( ) to set the timer. Start
programming mode using the down arrow ( ).
Use the left and right arrow keys ( ) to set the day (for example, Monday). Shift to
programming mode by pressing the down arrow ( ).
Choose the setting number (such as setting 1) with the left and right arrow keys ( ).
Shift to programming mode by pressing the down arrow ( ).
Use the up and down arrows ( ) to set the start hour, then shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows
( ).
To be changed more than once: Use the right arrow ( ) to move to end hour setting
and then the up and down arrows ( ) to set the end hour. Shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows ( ). Shift to
temperature with the right arrow ( ). Change the temperature using the up and down
arrows ( ). Shift to on/off with the right arrow ( ). Change the on/off mode using the
up and down arrows ( ).
Now the setting (Monday, setting 1) is done; press MENU to return to programming
mode. Programme the stand-by times for each day by moving to the day/setting with
the left and right arrow keys ( ). You can programme a maximum of four time
settings per day. When all settings are done, go back to timer settings by pressing
MENU twice, press ON, and the weekly settings are activated. To be changed more
than once: A red LED blinks until the sauna or steam bath starts at a set time; after this
it glows steadily (a text on the display tells when this happens).
To switch the Tylarium off manually, press OFF. (This only switches off the current
bath).
To de-programme the weekly settings, press MENU, use the left and right arrows (
) to shift to timer settings and press OFF.
PROGRAMMING THE WEEKLY TIMER
with the same setting for all days of the week.
Note: CC 100-0B/0S only
Setting on/off, temperature.
Press MENU – Use the left and right arrow keys ( ) to set the timer. Start
programming mode using the down arrow ( ).
Use the left and right arrow ( ) keys to select the mode WEEK. Shift to
programming mode by pressing the down arrow ( ).
Select the setting number (for example, setting 1) using the left and right arrow keys (
).
Use the down arrow ( ) to move the programming mode, then use the up and down
arrows ( ) to set the start hour. Shift to minutes with the right arrow ( ). Change the
minutes using the up and down arrows ( ).
Shift to end time setting using the right arrow ( ), then use the up and down arrows (
) to change the end time, then shift to minutes with the right arrow ( ). Change the
minutes using the up and down arrows ( ). Shift to temperature with the right arrow
(). Change the temperature using the up and down arrows ( ). Shift to on/off with
the right arrow ( ). Change the on/off mode using the up and down arrows ( ).
Now the setting (1) is done; press MENU to return to programming mode. Programme
each setting using the left and right arrow keys ( ). The Tylarium can be
programmed to switch on and off four times a day. When all settings are done, go back
to timer settings by pressing MENU twice, press ON, and the weekly settings are
activated. A red LED blinks until the sauna or steam bath starts at a set time; after this
it glows steadily (a text on the display tells when this happens).
To switch the Tylarium off manually, press OFF. (This only switches off the current
bath).
To de-programme the weekly settings, press MENU, use the left and right arrows (
) to shift to timer settings and press OFF.
STAND-BY PROGRAMMING
with different settings for different days of the week.
Note: CC 100-0B/0S only.
Press MENU – Use the left and right arrow keys ( ) to set the stand-by timer. Start
programming mode using the down arrow ( ).
Use the left and right arrow keys ( ) to set the day (for example, Monday). Shift to
programming mode by pressing the down arrow ( ).
Use the up and down arrows ( ) to set the start hour, then shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows
( ).
To be changed more than once: Switch to end time setting using the right arrow ( ),
use the up and down arrows ( ) to set the end hour, then shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows ( ). Shift to
temperature with the right arrow ( ). Change the temperature using the up and down
arrows ( ). Shift to on/off with the right arrow ( ). Change the on/off mode using the
up and down arrows ( ).
Now the stand-by setting (Monday, setting 1) is done; press MENU to return to
programming mode. Programme the stand-by time for each day. When all settings are
done, go back to stand-by settings in the MENU ON, and the stand-by settings are
activated. A red LED blinks until the sauna or steam bath starts at a set time; after this
it glows steadily (a text on the display shows that the panel is in a stand-by position and
when it will switch on).
As soon as you press ON, the temperature increases to the pre-set bathing
temperature. After 1 hour, the facility resumes the stand-by temperature. Each time the
ON button is pressed, a new 1-hour bathing period starts.
Note: if both the timer time and stand-by time are set to be on at the same time, the
timer function takes over.
To switch the Tylarium off manually, press OFF. (This only switches off the current
bath).
To be changed more than once: To de-programme the stand-by settings, press MENU,
use the left and right arrows ( ) to shift to the stand-by setting and press OFF.
To restart with the same settings, press MENU, go to stand-by using the left and right
arrows ( ), and press ON.
NOTE: Always block with a password after Standby programming.
STAND-BY PROGRAMMING
with the same setting for all days of the week.
Note: CC 100-0B/0S only.
Press MENU – Use the left and right arrow keys ( ) to set the stand-by timer. Start
programming mode using the down arrow ( ).
Use the left and right arrow ( ) keys to select the mode WEEK. Shift to
programming mode by pressing the down arrow ( ).
Use the up and down arrows ( ) to set the start time, then shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows ( ).
To be changed more than once: Switch to end time setting using the right arrow ( ),
use the up and down arrows ( ) to set the end hour, then shift to minutes with the
right arrow ( ). Change the minutes using the up and down arrows
( ). Shift to temperature with the right arrow ( ). Change the temperature using the
up and down arrows ( ). Shift to on/off with the right arrow ( ). Change the on/off
mode using the up and down arrows ( ).
Now the stand-by time is programmed in. Go back to stand-by programming by
pressing MENU twice, press ON. A red LED blinks until the sauna or steam bath starts
at a set time; then it glows steadily (a text on the display tells that the panel is on stand-
by and when it will switch on).
As soon as you press ON, the temperature increases to the pre-set bathing temperature.
After 1 hour, the facility automatically resumes stand-by temperature. Each time you
press ON, 1 hour’s bathing time begins.
Note: if both the timer time and stand-by time are set to be on at the same time, the
timer function takes over.
To switch the Tylarium off manually, press OFF. (This only switches off the current
bath).
To be changed more than once: To de-programme the stand-by settings, press MENU,
use the left and right arrows ( ) to shift to the stand-by setting and press OFF.
To restart with the same settings, press MENU, go to stand-by using the left and right
arrows ( ), and press ON.
NOTE: Always block with a password after Standby programming.
Password.
Setting the password.
Press MENU – Use the right and left arrows ( ) to go to password setting. Start
programming mode by pressing the down arrow ( ). Enter the code using all the arrow
keys ( ). After power failure, the code is reset to 1995). Press MENU, use the
left arrow key ( ) to change the code. Set the new code using all the arrow keys (
). Press MENU. Activate on/off with the right arrow ( ), press MENU. Now the
password is activated.
To return to unlocked mode, repeat the above procedure but set on/off to off.
Note: Do all other settings before setting the password.
BATHING OUTSIDE OF THE PROGRAMMED TIME
if the panel is locked with a password.
The sauna or steam bath can be used at a different time than the programmed time.
Press ON to start a one-hour bathing period. To extend the bath, press ON again. The
facility automatically switches off one hour after the last time ON was pressed.
TYLÖ AB, Svarvaregatan 6, S-30250 Halmstad, Sweden.
Phone 035-299 00 00, Fax 035-299 01 98
© This publication may not be reproduced, in part or in whole, without the written permission of Tylö. Ty
reserves the right to make changes in materials, construction and design.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Tylö CC 100-0B Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI