PROG.
- PRESS PUSH - BUTTON FOR ABOUT 2 SECS. : THE DISPLAY VISUALIZES :
GRUOP 2 : ENTER CODE 2413 E PREMERE ENT
QUIT PROGRAMMING
PROG
ENT
ENT
ENT
Up - dating time for visualized data, between 0 and 4 secs. included.
If set = 0 visualization is istantaneous.
Delay time for automatic resetting, between 0 and 99,9 secs included
If set = 0 Automatic Reset
Input Impuls Speed programming :
- S = SLOW input 20 Hz ( electromechanic contacts )
- F = FAST input 2 KHz or 20 KHz ( logic signal )
RES
PRESS PUSH - BUTTON OUTSIDE PROGRAMMING FOR NEW VALUE ENTERING ACCESS
ENT
ENT
ENT
Time Visualization Scale programming
- 1 = 99h59m59s - 2 = 999999s
- 3 = 9999m99cm - 4 = 99h59m99cm
There are 4 available scale :
Push - button Reset funcioning programming:
- on = Push - button Reset Activ
- OFF = Push - button Reset not activt
FRONT PUSH - BUTTON PANEL
CALCULATION PARAMETERS PROGRAMMING
CALCULATION PARAMETERS PROGRAMMING
PROG
RED
BLUE
YELLOW
YELLOW During programming mode cursor moves to the left.
During normal mode allows temporary visualization of the programmed data
During programming mode increases the flashing figures.
During normal mode visualizes the previously set data on totalizer.
Access and quit from the programming mode .
During programming mode confirms the data and passes to the next ( ENT ).
During normal mode resets the device ( RES ).
RES
ENT
THE PROGRAMMABLE PARAMETERS ARE DIVIDED INTO TWO GROUPS PROTECTED BY A 4 FIGURE CODE
IN ORDER TO OBTAIN ACCESS TO PROGRAMMING, PROCEED AS FOLLOW :
- PRESS PUSH - BUTTON PROG
GRUOP 1 : ENTER CODE 2357 ENT
ENT
Multiplier of the impulses is programmable from 1 to 999999
Divisor of the impulses is programmable from 1 to 9999
ENTPROG
QUIT PROGRAMMING
PRESS PUSH - BUTTON RES OUTSIDE PROGRAMMING FOR NEW VALUE ENTERING ACCESS
AND PUSH
ENT
FOR ABOUT 2 SECS. : THE DISPLAY VISUALIZES