Symmetra PX

APC Symmetra PX Product information

  • Hello! I am an AI chatbot trained to assist you with the APC Symmetra PX Product information. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SymmetraPX
250/500kW400/480V
SingleandParallelOperation
TableofContents
Overview..............................................................................................................................1
Symbolsused...............................................................................................................3
ParallelSystemSummary..........................................................................................3
UPSSummaryScreen................................................................................................4
SingleSystem............................................................................................................4
ParallelSystem..........................................................................................................4
OperationModes............................................................................................................5
UPSModes....................................................................................................................5
NormalOperation......................................................................................................5
Batteryoperation.......................................................................................................6
Requestedstaticbypassoperation/forcedstaticbypassoperation..........................7
Batterytest................................................................................................................8
SystemModes..............................................................................................................9
On..............................................................................................................................9
Off..............................................................................................................................9
Requestedstaticbypassoperation/forcedstaticbypassoperation..........................9
Maintenancebypassoperation..................................................................................10
AutostartCountdown................................................................................................11
OperationProcedures.................................................................................................12
AccessScreensProtectedbyUserPassword....................................................12
StartUpSystemfromMaintenanceBypassOperation.....................................13
ShutDownSystemfromNormaltoMaintenanceBypassOperation............15
TransferfromNormaltoRequestedStaticBypassOperation........................17
TransferfromRequestedStaticBypasstoNormalOperation........................18
IsolatethisSingleUPSfromtheParallelSystem...............................................20
AddUPStoaRunningParallelSystem.................................................................21
AccessaConguredNetworkManagementCard..............................................23
OperatetheAPCBatteryBreakerManually..........................................................24
Conguration....................................................................................................................25
AccesstheUserCongurationScreen..................................................................25
PerformaBatteryRuntimeCalibration..................................................................26
990–2748E-001
SymmetraPX250/500kW400/480V
i
SettheBatteryTestSettings....................................................................................26
SettheDisplaySettings.............................................................................................28
SettheNetworkManagementCard(NMC)Settings...........................................29
SettheUserPasswordSettings..............................................................................30
SettheAlarmSettings................................................................................................31
SettheSystemTime...................................................................................................33
SettheLanguageandRegionalSettings..............................................................34
Maintenance......................................................................................................................36
AccessPredictiveMaintenanceScreen................................................................36
DetermineifyouneedaReplacementPart..........................................................37
ReturnPartstoAPC....................................................................................................38
User-ReplaceableParts..............................................................................................38
BatteryModuleReplacement....................................................................................38
DirectionsforReplacement.......................................................................................38
DirectionsforStorage...............................................................................................39
ReplaceBatteries.......................................................................................................40
ReplacePowerModules.............................................................................................40
ReplaceIntelligenceModules...................................................................................42
ReplaceBoardsinInput/Output/BypassEnclosure...........................................43
ReplaceBoardsintheBatteryEnclosure.............................................................44
Troubleshooting..............................................................................................................45
Alarms.............................................................................................................................45
AlarmButton.............................................................................................................45
AlarmLevels..............................................................................................................45
ViewtheActiveAlarms...............................................................................................46
ViewtheEventLog......................................................................................................47
BookmarkanEntryintheEventLog......................................................................50
ViewandSaveInformationaboutFirmwareVersion.........................................51
ReboottheDisplay......................................................................................................53
ii
SymmetraPX250/500kW400/480V
990–2748E-001
Overview
DisplayOverview
Note:Thescreensshowninthismanualsareexamplesonly.
TheUPSgraphicaluserinterfaceislocatedin
theInput/Output/BypassEnclosure.TheUPS
utilizesthetouch-screendisplaytocongureand
monitorthesystem,andprovidestheuserwith
visibleandaudiblealarms.
Thescreensareorganizedhierarchically.In
parallelsystemstheParallelSystemSummary
screenisatthetopofthehierarchy.Insingle
systemstheUPSSummaryscreenisatthetopof
thehierarchy.
OverviewofBreakersintheMBwD(Option)
Note:TheMBwDisonlyapplicableforsinglesystems.
TheAPCMBwDcontainsthebreakersQ1,Q2,
Q3,andQ5.Whentheassociatedbreakerlamp
islit,itisoktoopenandclosethebreaker.
To Distribution Breakers
990–2748E-001
SymmetraPX250/500kW400/480V
1
Navigation
ParallelSystem
Summary
ParallelInput
Summary
ParallelBypass
Summary
ParallelOutput
Summary
UPSSystem
UPSSummary
UPSInput
Summary
UPSBypass
Summary
UPSBattery
Summary
SystemStatus
SubfeedSummary
UPSOutput
Summary
UPSSystem
SystemInformation
SystemStatus
EventLog
FirmwareOverview
Predictive
Maintenance
Conguration
UserConguration
Service
Conguration
Factory
Conguration
Operation
Start-Up
Shutdown
Transfertonormal
operation
Transfertostatic
bypass
IsolatethisUPS
LanguageSettings
RegionalSettings
2
SymmetraPX250/500kW400/480V
990–2748E-001
Symbolsused
WARNING:Indicatesanelectricalhazard,which,ifnotavoided,couldresultin
injuryordeath.
Caution:Indicatesahazard,which,ifnotavoided,couldresultininjuryordeath.
Note:Indicatesimportantinformation.
See:Indicatesthatmoreinformationisavailableonthissubject.
ParallelSystemSummary
TheParallelSystemSummaryscreenisthehomescreeninparallelsystems.Itprovidesyouwithan
overviewoftheparallelsystemandcircuitbreakers.Itshowsthesystemstatusandthepowerow
throughthesystemandgivesaccesstothesystem’ssummaryscreens.
Note:TheoperatedUPSishighlightedonthescreenandtheotherUPSunitsarefaded.
A.Accessfurtherdetailsonthecurrent
screen.
B.GototheUPSSystemscreen.
C.GototheParallelInputSummaryscreens.
D.GototheParallelBypassSummary
screens.
E.GototheParallelOutputSummary
screens.
F.GototheUPSSummaryscreens.
990–2748E-001
SymmetraPX250/500kW400/480V
3
UPSSummaryScreen
SingleSystem
Insinglesystems,theUPSSummaryscreenisthehomescreen.Itprovidesyouwithanoverviewof
theUPSsystemandcircuitbreakers.Itshowsthesystemstatusandthepowerowthroughthesystem
andgivesaccesstothesystem’ssummaryscreensandtheUPSSystemscreen.
A.Accessfurtherdetailsonthecurrent
screen.
B.GototheUPSSystemscreen.
C.GototheSystemStatusscreenforthe
currentUPS.
D.GototheBypassSummaryscreens.
E.GototheInputSummaryscreens.
F.GototheOutputSummaryscreens.
G.GototheBatterySummaryscreens.
H.Logoutofpasswordprotectedscreens.
ParallelSystem
Inparallelsystems,theUPSSummaryscreenprovidesyouwithanoverviewoftheactualUPSand
circuitbreakers.ItshowsthesystemstatusandthepowerowthroughtheUPSandgivesaccesstothe
system’ssummaryscreensandtheUPSSystemscreen.
A.Accessfurtherdetailsonthecurrent
screen.
B.GototheUPSSystemscreen.
C.GototheSystemStatusscreenforthe
currentUPS.
D.GototheBypassSummaryscreens.
E.GototheInputSummaryscreens.
F.GototheOutputSummaryscreens.
G.GototheBatterySummaryscreens.
H.GototheParallelSystemSummaryscreen.
I.Gotothepreviousscreen.
J.Logoutofpasswordprotectedscreens.
4
SymmetraPX250/500kW400/480V
990–2748E-001
OperationModes
UPSModes
TheUPSoperationmodeisindicatedinthetoprightcornerofthescreenundertheheadingUPS
Mode.TheUPSmodeindicatesthecurrentstatusoftheoperatedUPS.
NormalOperation
Duringnormaloperation,theUPSsupportsthecriticalloadwithconditionedpower.WhiletheUPSis
operatinginnormaloperation,asingle-linediagramwillappearonthescreen.Agreenlineindicates
thepowerowfromtheutility/mains,throughtheUPSsystem,andtotheload.Thegreenlinetothe
batteriesindicatesthatthebatteriesareconnected.
SingleSystemParallelSystem
or
990–2748E-001
SymmetraPX250/500kW400/480V
5
Batteryoperation
Iftheutility/mainssupplyfails,theUPStransferstobatteryoperation.Duringbatteryoperation,
batterypowerensuresuninterruptedsupporttothecriticalload.WhiletheUPSsystemisinbattery
operation,asingle-linediagramwillappearonthescreen.Thegreenlineindicatesthepowerow
fromthebatteries,throughtheinverters,andthentotheload.
SingleSystemParallelSystem
or
6
SymmetraPX250/500kW400/480V
990–2748E-001
Requestedstaticbypassoperation/forcedstaticbypassoperation
TheUPSisinrequestedstaticbypassfollowingacommandfromthegraphicaluserinterface.And
theUPSisinforcedbypasswhenafaultonthesystemhascausedstaticbypassoperation.During
staticbypassoperation,thecriticalloadissupplieddirectlybyutility/mainspower.WhiletheUPSis
operatinginthismode,asingle-linediagramwillappearonthescreen.Theorangelineindicatesthe
powerowfromtheutility/mainsthroughthebypassstaticswitch,andthentothecriticalload.
Note:Thebatteriesarenotavailableasanalternatepowersourcewhilethesystemis
inforcedstaticbypassoperation.Thebatteriesareavailableinrequestedbypass,and
itispossibletomanuallytransfertonormaloperation.Ifthereisaninterruptiontothe
utility/mainspowersupplyduringrequestedstaticbypassoperation,thesystemwill
transfertobatteryoperation.Thiswillcauseaninterruptiontothepowersupplyingthe
loadandmayresultinaloaddrop.
SingleSystemParallelSystem
or
990–2748E-001
SymmetraPX250/500kW400/480V
7
Batterytest
TheUPSisinbatterytestmodewhentheUPSisperformingabatteryself-test.Duringbatterytest,
thebatteryruntimecapacityisreducedby10%.
Note:Thebatterytestwillstopifthemainssupplyfailsduringthetest.
SingleSystemParallelSystem
or
8
SymmetraPX250/500kW400/480V
990–2748E-001
SystemModes
ThesystemmodeisindicatedinthetoprightcornerofthescreenundertheheadingSystemMode.The
systemmodeindicatesthecurrentoutputstatusofthecompletesystem,andnottheindividualUPSunit.
On
WhenthesystemmodeisOn,theUPSsystemsupportsthecriticalloadwithconditionedpower.The
loadissupportedbytheUPSinbothnormalandbatteryoperation.
Off
WhenthesystemmodeisOff,theUPSsystemdoesnotsupporttheconnectedloadwithpower.
Requestedstaticbypassoperation/forcedstaticbypassoperation
TheUPSisinrequestedstaticbypassfollowingacommandfromthegraphicaluserinterface.And
theUPSisinforcedbypasswhenafaultonthesystemhascausedstaticbypassoperation.During
staticbypassoperation,thecriticalloadissupplieddirectlybyutility/mainspower.WhiletheUPSis
operatinginthismode,asingle-linediagramwillappearonthescreen.Theorangelineindicatesthe
powerowfromtheutility/mainsthroughthebypassstaticswitch,andthentothecriticalload.
990–2748E-001
SymmetraPX250/500kW400/480V
9
Maintenancebypassoperation
Duringmaintenancebypassoperation,thecriticalloadissupplieddirectlybyutility/mainspower.
WhiletheUPSsystemisinmaintenancebypassoperation,asingle-linediagramwillappearon
thescreen.Theorangelineindicatesthepowerowfromtheutility/mains,andthentothecritical
loadviatheQ3switch.
Note:ThebatteriesarenotavailableasanalternatepowersourcewhiletheUPSsystem
isinmaintenancebypassoperation.
SingleSystemParallelSystem
or
10
SymmetraPX250/500kW400/480V
990–2748E-001
AutostartCountdown
ThesystemcanbesetupforanautomaticstartwhenACutilitypowerisrestoredfollowingalow
batteryvoltageshutdown.Theautostartcountdownwindowisshownoverallscreensuntilthe
countdownperiodexpiresortheautostartismanuallystoppedbypressingthestopbutton.
Thisfeatureisdisabledbydefaultandisnotsupportedinparallelsystems.ContactAPCifthis
featureshouldbeenabled.
990–2748E-001
SymmetraPX250/500kW400/480V
11
OperationProcedures
AccessScreensProtectedbyUserPassword
1.Whenpromptedfortheuser-password,pressthepasswordeldtoaccessthekeyboard.
2.TypeintheuserpasswordandpressEnter.
Note:Oninstallation,theuserpasswordissetto“apc”.
12
SymmetraPX250/500kW400/480V
990–2748E-001
StartUpSystemfromMaintenanceBypassOperation
Note:Start-upcondition:TheloadissuppliedviatheQ3switchfromtheutility/mains,
andtheotherbreakersareopen.
1.ClosetheUPSinputbreaker(Q1).ThiswillpoweruptheUPSdisplay.
2.PresstheUPSSystembuttoninthebottomleftcornertoaccesstheUPSSystemscreen.
SingleSystemParallelSystem
3.PresstheOperationbutton.TypeintheuserpasswordandcompletewithEnter.
4.PressSystemStart-upbutton.
SingleSystemParallelSystem
990–2748E-001
SymmetraPX250/500kW400/480V
13
5.Followthestepswhichappearonthescreen.Stepswillappearintheorderinwhichthey
needtobecompleted.Astepwillinitiallyappearinredandthenwhenitiscompleted,the
stepwillchangetogreen.Thenextsteptobecompletedwillbehighlightedinredtextand
yellowbackground.
Note:Greybuttonsaretouch-screenfunctions.
SingleSystemParallelSystem
6.CheckthattheUPSModeisNormalOperationintheupperrightcorner.
14
SymmetraPX250/500kW400/480V
990–2748E-001
ShutDownSystemfromNormaltoMaintenance
BypassOperation
Note:PressthehomebuttontogototheUPSSummaryorParallelSystemSummary
screen.
1.PresstheUPSSystembuttoninthebottomleftcornertoaccesstheUPSSystemscreen.
SingleSystemParallelSystem
2.PresstheOperationbutton.TypeintheuserpasswordandcompletewithEnter.
3.PresstheSystemShutdownbuttonontheOperationscreen.
SingleSystemParallelSystem
990–2748E-001
SymmetraPX250/500kW400/480V
15
4.Followthestepswhichappearonthescreen.Stepswillappearintheorderinwhichthey
needtobecompleted.Astepwillinitiallyappearinredandthenwhenitiscompleted,the
stepwillchangetogreen.Thenextsteptobecompletedwillbehighlightedinredtextand
yellowbackground.
Note:Greybuttonsaretouch-screenfunctions.
SingleSystemParallelSystem
Note:ThedisplaywillturnoffwhentheUPSinputbreaker(Q1)isopened.
Caution:DonotopentheQ3breakerwhenthesystemisinmaintenancebypass
operation,asitmayresultinaloaddrop.
16
SymmetraPX250/500kW400/480V
990–2748E-001
/