Barco MXRT-7300 is a high-performance medical display controller that provides reliable image quality and accurate color reproduction for critical medical applications. It supports 4K UHD resolution, 3D stereo visualization, and a wide range of video inputs, making it suitable for various medical imaging modalities such as endoscopy, radiology, and surgical microscopy. With its advanced features like DICOM calibration and compliance, the MXRT-7300 ensures precise and consistent image display for diagnostic purposes.

Barco MXRT-7300 is a high-performance medical display controller that provides reliable image quality and accurate color reproduction for critical medical applications. It supports 4K UHD resolution, 3D stereo visualization, and a wide range of video inputs, making it suitable for various medical imaging modalities such as endoscopy, radiology, and surgical microscopy. With its advanced features like DICOM calibration and compliance, the MXRT-7300 ensures precise and consistent image display for diagnostic purposes.

Release Notes K5905159 rev 16
Release Date: Oct 31, 2019
P 1 / 5
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Barco Med Self Exam (BMSE)
v 6.5.6.0
Release Notes K5905159 rev 16
Release Date: Oct 31, 2019
P 2 / 5
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
BMSE v6.5.6.0
Updated summary page to capture additonal display information such as connection type,
current resolution
Legacy Revisions
1.4.0 / 6.4.0 - June 16, 2010
included short Desktop Summary at top of file ( http://itrack.barco.com/browse/MI0130-
35 )
list what board is connected to a montior ( http://itrack.barco.com/browse/MI0130-34 )
released with 8.682.7.2 - first WDDM 1.1 driver
1.4.1 / 6.4.1 – July 2, 2010
Made sure info that customer Cerner needs is in text file and html file.
Cleaned up the text file with better formatting and more information.
Report the driver version number consistently between MXRT’s XPDM and WDDM drivers.
Report the monitor name better when connected to non-Barco graphics card.
Updated to use barcomedlibrary class to clean up code.
1.4.2 / 6.4.2 – August 2, 2010
includes barcomed.dll version 1.2.88.0. The previous version of barcomed.dll ( 1.2.86.0 )
had a bug – see MI0182-295 for more information.
1.4.3 / 6.4.3 – September 7, 2010
includes barcomed.dll version 1.2.90.0
Fix for MI0130-38, BMSE could crash if any of its diagnostics ran into problems (e.g.,
OpenGL crash). Added try/catch around all diagnostics. Also fixed problem where if
language files are missing, BMSE will detect the issue.
Upgraded to newer SDK.
1.4.4 / 6.4.4 – September 17, 2010
Change the shortcut in Start->Program Files from “Barco Medical” to “Barco”
Fix for MI0130-40 – fonts in titles were too big (version 1.4.3. only. This was a side
effect of switching to the new SDK. The bug had been there all along, but we got away
with it with the old SDK.
1.4.5 / 6.4.5 – December 4, 2010
Support EDID 1.4 - MI0130-41
No long requires the user to be administrator. If the user is administrator, then the
reports are the same. However, if the user is not the administrator boot information is
not gathered. MI0130-31
Reports DWM status in vista/win7 - MI0130-42
Release Notes K5905159 rev 16
Release Date: Oct 31, 2019
P 3 / 5
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Reports the videoprt.sys version - MI0130-32
Added code to overwrite the event logs if they already exist in the report folder MI0130-
18
Next button does not stay grayed out till all fields are filled in MI0130-29
Enable Window’s visual styles
1.4.6 / 6.4.6 – Feb 6, 2011
Add setupapi files to BMSE report. MI0130-33
BMSE opens browser window before silent mode completes. MI0130-51
BMSE customer information was being appended with old data. MI0130-47
Added Selected and Measured DVI Link. MI0130-49
BarcoMFD.dll load was stalling, causing BMSE to freeze. MI0295-300
Restructure the BMSE format of the html file (MI0130-53, MI0130-36)
Copy BarcoDisplayTools.log created by display tools API (MI0130-52)
1.4.7 / 6.4.7 – Feb 23, 2011
Fixed translation issues (MI0130-11, MI0130-13)
Report if Single-Link or Dual-Link dongle is being used (MI0130-48). Note, this is
supported by BMSE, but it requires the driver to support this too.
Add Firmware Version of Dual-Link DP2DVI dongle to BMSE Report (MI0130-43) Note,
this is supported by BMSE, but it requires the driver to support this too.
Add Connection Type (SL DP->DVI Dongle, DL DP->DVI Dongle, Native DP, Native DVI,
Analog, etc) to BMSE Report (MI0130-50 )
Add section to BMSE to retrieve the mode and timing list for each display from the MXRT
driver and retrieve the windows mode list from windows for all boards (MI0130-37). Note,
gathering the modelist from Windows works, but gathering the modelist from the driver
requires driver changes and is marked unsupported.
MI0130-26 Update BMSE to report the following:
GetLuminanceRange: "Monitor Luminance: "
GetBacklightRuntime "Monitor Backlight Runtime: "
GetFirmwareVersion "Monitor Boot Version: "
GetFirmwareVersion "Monitor Run Firmware Version: "
GetFirmwareVersion "Monitor CPLD Version: "
GetFirmwareVersion "Monitor FPGA1 Version: "
GetFirmwareVersion "Monitor FPGA2 Version: "
Non english system: last screen of BMSE, layout was not good (MI0130-16)
Headers unreadable in BMSE wizard (MI0130-45)
When cancelling on the 4th page (gathering diagnostic data) before the process is started
results in a previous report being deleted (MI0130-17)
Include display DPMS + Windows power save settings in report (MI0130-54)
MI0130-25 Progress message regarding boot file is inaccurate – English only
1.4.8 / 6.4.8 – March 8, 2011
Update barcomed.dll to version 1.3.8.0
1.4.9 / 6.4.9 – April 20, 2011
Release Notes K5905159 rev 16
Release Date: Oct 31, 2019
P 4 / 5
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
Update to barcomed.dll version 1.3.12.0
Translation issues:
o MI0130-56 Issue with Japanese language, application hangs when selecting help
o MI0130-55 Issue with Chinese simplified language, application hangs when
selecting help
o MI0130-58 Errors in the dutch translation of the help
o MI0130-62 BMSE: some of the Help files for Asian languages appear in different
format
MI0130-64 - Changes to alert user when event logs are not copied (e.g. due to lack of
administrative rights)
MI0130-57 Fixed the bug: On the customer information window: cancel and help button
needs to be clicked twice
1.4.10 / 6.4.10 – May2, 2011
Includes barcomed.dll version 1.3.12.0
Added EnableDDCForAll registry entries to report (MI0130-68)
Fixed GetUSWCFromRegistry (iTrack MI0130-66)
Used with 8.743.7.4 release
1.4.11 / 6.4.11 – May 27, 2011
Includes barcomed.dll version 1.3.14.0
Adding Display Runtime to the report. This is the amount of time the display has been
powered, regardless of whether the backlight was running or not. MI0130-69
1.4.12 / 6.4.12 – November 15, 2011
Reports serial number of MXRT x4xx cards, when available
1.4.13 / 6.4.13 – February 1, 2012
Updates barcomed.dll to version 1.3.26.0
1.4.14 / 6.4.14 – June 25, 2012
Updates barcomed.dll to version 1.3.32.0
Added reporting ASIC temperature to BMSE report
1.4.15 / 6.4.15 – July 31, 2012
Adds Scaled Clone information to BMSE
1.4.16 / 6.4.16 – January 10, 2012
Adds Display Stock Number information to BMSE
Added BarcoMFD, Boards32, and Boards32Basics DLLs to install package
Release Notes K5905159 rev 16
Release Date: Oct 31, 2019
P 5 / 5
Barco nv | Beneluxpark 21 | B-8500 Kortrijk | Belgium
Registered office: President Kennedypark 35 | B-8500 Kortrijk | Belgium
IBAN BE49 3850 5234 2071 BBRUBEBB | VAT BE 0473.191.041 | RPR Gent, Section Kortrijk
www.barco.com
1.5.0 / 6.5.0 – February 23, 2016
changes from x.4.29: adds Win10 support
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Barco MXRT-7300 Owner's manual

Type
Owner's manual

Barco MXRT-7300 is a high-performance medical display controller that provides reliable image quality and accurate color reproduction for critical medical applications. It supports 4K UHD resolution, 3D stereo visualization, and a wide range of video inputs, making it suitable for various medical imaging modalities such as endoscopy, radiology, and surgical microscopy. With its advanced features like DICOM calibration and compliance, the MXRT-7300 ensures precise and consistent image display for diagnostic purposes.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI