ETERNUS DX100 S3

Fujitsu ETERNUS DX100 S3, ETERNUS DX200 S3, ETERNUS DX60 / DX80, ETERNUS DX60 S2, ETERNUS DX60 S3, ETERNUS DX80 S2, ETERNUS DX90 S2 User manual

  • Hello! I am an AI chatbot trained to assist you with the Fujitsu ETERNUS DX100 S3 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
FUJITSU Storage
ETERNUS DX
Configuration Guide -Server Connection-
(SAS) for Oracle Solaris
P3AM-3452-13ENZ0
This page is intentionally left blank.
Preface
This manual briefly explains the operations that need to be performed by the user in order to connect an
ETERNUS DX to a server running Solaris OS via a SAS interface.
This manual should be used in conjunction with any other applicable user manuals, such as those for the
ETERNUS DX, server, OS, SAS cards, and drivers.
Refer to "FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- Notations" for the notations
used in this manual such as product trademarks and product names. For storage systems that are supported
by the OS, refer to the Server Support Matrix of the ETERNUS DX.
13th Edition
June 2015
The Contents and Structure of this Manual
This manual is composed of the following ten chapters.
"Chapter 1 Workflow" (page 6)
This chapter describes the workflow required to connect a server running Solaris OS to an ETERNUS DX.
"Chapter 2 Checking the Server Environment" (page 8)
This chapter describes which servers can be connected to ETERNUS DX storage systems.
"Chapter 3 Notes" (page 9)
This chapter describes issues that should be noted when connecting the ETERNUS DX storage systems and
server.
"Chapter 4 Setting Up the ETERNUS DX" (page 10)
This chapter describes how to set up an ETERNUS DX.
"Chapter 5 Setting Up the SAS Switches" (page 11)
This chapter describes how to set up the SAS switches.
"Chapter 6 Installing the Driver" (page 13)
This chapter describes how to install the SAS card drivers.
"Chapter 7 Setting Up the Server" (page 14)
This chapter describes how to make the server recognize the SAS cards.
"Chapter 8 Installing the Multipath Driver" (page 16)
This chapter describes how to install the Multipath Drivers.
"Chapter 9 Setting the Multipaths" (page 17)
This chapter describes how to switch from single path connection to multipath connection.
"Chapter 10 ETERNUS DX Boot using a SAS Card" (page 19)
This chapter provides notes for an ETERNUS DX LUN Boot.
3
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Table of Contents
Chapter 1 Workflow 6
Chapter 2 Checking the Server Environment 8
2.1 Hardware ....................................................................................................................................... 8
2.2 OS (Operating System)................................................................................................................... 8
2.3 SAS Cards........................................................................................................................................ 8
2.4 Multipath Driver ............................................................................................................................. 8
Chapter 3 Notes 9
3.1 Server Startup Notes....................................................................................................................... 9
3.2 ETERNUS Multipath Notes .............................................................................................................. 9
3.3 MPxIO Notes................................................................................................................................... 9
Chapter 4 Setting Up the ETERNUS DX 10
Chapter 5 Setting Up the SAS Switches 11
Chapter 6 Installing the Driver 13
6.1 For Fujitsu SAS Cards .................................................................................................................... 13
6.2 For Oracle SAS Cards ..................................................................................................................... 13
Chapter 7 Setting Up the Server 14
7.1 For Cards Other than Fujitsu's 3Gbit/s SAS Cards........................................................................... 14
7.2 For Fujitsu's 3Gbit/s SAS Cards ...................................................................................................... 15
Chapter 8 Installing the Multipath Driver 16
8.1 For ETERNUS Multipath Driver ...................................................................................................... 16
8.2 For MPxIO..................................................................................................................................... 16
Chapter 9 Setting the Multipaths 17
9.1 For ETERNUS Multipath Driver ...................................................................................................... 17
4
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
9.2 For MPxIO..................................................................................................................................... 17
9.2.1 For 12Gbit/s SAS Cards ........................................................................................................................................17
9.2.2 For 6Gbit/s SAS Cards ..........................................................................................................................................18
9.2.3 For 3Gbit/s SAS Cards ..........................................................................................................................................18
Chapter 10 ETERNUS DX Boot using a SAS Card 19
Table of Contents
5
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 1
Workflow
Which documents need to be referred to varies with the connection environment. Refer to the workflow that
follows to determine which documents are required.
Required Documents
"Server Support Matrix"
"FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- Disk Storage System Settings" that
corresponds to the ETERNUS DX to be connected
"ETERNUS Web GUI User's Guide"
Manuals supplied with the server, SAS cards, and multipath driver
Workflow
Setting Up the ETERNUS DX
Set up the ETERNUS DX using ETERNUS Web GUI.
"Chapter 2 Checking the Server Environment" (page 8)
"Chapter 4 Setting Up the ETERNUS DX" (page 10)
Checking the setup and maintenance operations
-"ETERNUS Web GUI User's Guide"
Setting up the ETERNUS DX
-"FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- Disk Storage System Set-
tings" that corresponds to the ETERNUS DX to be connected
Setting Up the SAS Switches
Set up the SAS switch.
"Chapter 5 Setting Up the SAS Switches" (page 11)
6
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Installing the Driver
Install the appropriate driver for the SAS card being used.
"Chapter 6 Installing the Driver" (page 13)
Checking the SAS card driver versions
-"Server Support Matrix"
Setting Up the Server
Set the parameters required for connection to the ETERNUS DX.
"Chapter 7 Setting Up the Server" (page 14)
Setting Up the Server to Recognize the Logical Units
Set up the server so that it can recognize the LUNs (logical unit numbers) of the ETERNUS DX.
Setting the Multipaths
Install the Multipath Driver and set up the multipath connections.
"Chapter 8 Installing the Multipath Driver" (page 16)
"Chapter 9 Setting the Multipaths" (page 17)
Creating Volumes and File System
Create slices and a file system, exactly the same as for a regular disk.
Chapter 1 Workflow
7
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 2
Checking the Server Environment
The ETERNUS DX can be connected via a SAS interface to a server that meets the following requirements.
Check the "Server Support Matrix" for server environment conditions.
2.1 Hardware
Refer to the "Server Support Matrix".
2.2 OS (Operating System)
Refer to the "Server Support Matrix".
2.3 SAS Cards
Refer to the "Server Support Matrix".
2.4 Multipath Driver
When using the ETERNUS Multipath Driver or MPxIO, refer to the "Server Support Matrix".
8
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 3
Notes
Note the following issues when connecting the ETERNUS DX to a server.
3.1 Server Startup Notes
Before turning the server on, check that the ETERNUS DX storage systems are "Ready". If the server is turned
on and they are not "Ready", the server will not be able to recognize the ETERNUS DX storage systems.
Also, when the ETERNUS DX power supply is being controlled by a UPS power supply linkage, make sure that
the ETERNUS DX is never turned off before the connected servers. If this happens, data from the running
server cannot be saved to the ETERNUS DX storage systems, and already saved data may be damaged.
3.2 ETERNUS Multipath Notes
ETERNUS Multipath Driver requirements
Requirement Remarks
ETERNUS Multipath Driver version and patch level V3.0.0 or later, patch 914267-06 or later
Refer to the documentation supplied with each product for installation and setup details.
3.3 MPxIO Notes
MPxIO requirements
Requirement Remarks
Multipath Driver Bundled with OS
When connecting the ETERNUS DX storage systems to a server with MPxIO installed, host responses must
be set for the ETERNUS DX storage systems.
Refer to the "Sun StorEdge Traffic Manager Installation and Configuration Guide" on the Oracle web-site
(http://www.oracle.com) for MPxIO setup details.
9
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 4
Setting Up the ETERNUS DX
Set up the ETERNUS DX storage systems using ETERNUS Web GUI.
ETERNUS DX setup can be performed independently of server setup. For details on how to perform these set-
tings, refer to the following manuals.
"FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- Disk Storage System Settings" that
corresponds to the ETERNUS DX to be connected
"ETERNUS Web GUI User's Guide"
10
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 5
Setting Up the SAS Switches
The following describes the required settings when connecting the server and the ETERNUS DX storage sys-
tems using a SAS switch. For details, refer to the SAS switch manual.
The following examples show configurations in which a server is connected to a SAS switch with zoning.
The following example shows a configuration in which multiple servers are connected to multiple CAs.
Port2Port0 Port6Port4
Port3Port1 Port7Port5
Port2Port0 Port6Port4
Port3Port1 Port7Port5
CA00 CA01 CA10 CA11
CM0 CM1
Name : RAID#1
ZONE1 ZONE2 ZONE3
ZONE4
ETERNUS DX
SAS switch SAS switch
Name : Server#1
Slot 1Slot 0
Name : Server#2
Slot 1Slot 0
11
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
The following example shows a configuration in which a single server is connected to multiple CAs.
Port2Port0 Port6Port4
Port3Port1 Port7Port5
Port2Port0 Port6Port4
Port3Port1 Port7Port5
CM0 CM1
ZONE1
ZONE2
ZONE3 ZONE4
ETERNUS DX
P0 P1 P0 P1
Slot 1
Server
Slot 0
SAS switch SAS switch
Chapter 5 Setting Up the SAS Switches
12
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 6
Installing the Driver
6.1 For Fujitsu SAS Cards
Refer to the documentation supplied with the product for installation details.
6.2 For Oracle SAS Cards
Driver is bundled with OS. Installation is not necessary.
13
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 7
Setting Up the Server
7.1 For Cards Other than Fujitsu's 3Gbit/s SAS Cards
1Edit the configuration file.
Specify an arbitrary command queue depth (*1) by setting the "sd_max_throttle" parameter in the con-
figuration file ("/etc/system").
If the "sd_max_throttle" parameter does not exist, it should be added.
set sd:sd_max_throttle = 8
*1: Recommended value = 512 ¸ (number of SAS ports that are connected to a single CA port) ¸ num-
ber of LUNs
(Round the result down)
Use the value of "8" if the actual result is lower.
2After editing the configuration file, save it.
The configuration file should also be checked for incorrect settings.
3Execute the following command to reboot the server.
# touch /reconfigure
# /usr/sbin/shutdown -y -g0 -i6
14
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
7.2 For Fujitsu's 3Gbit/s SAS Cards
Set up the server according to the following procedure for a single-path configuration.
1Edit the configuration file.
Specify an arbitrary command queue depth (*1) to "max-throttle" in the driver definition file
(/platform/{sun4v|SUNW,SPARC-Enterprise}/kernel/drv/fjulsa.conf).
target#-max-throttle=40;
("#:SCSI ID, 40:" shows the number of data transfer requests that can be issued simultaneously)
*1: Recommended value = 512 ¸ (number of SAS ports that are connected to a single CA port) ¸ num-
ber of LUNs
(Round the result down)
Use the value of "8" if the actual result is lower.
2After editing the configuration file, save it.
The configuration file should also be checked for incorrect settings.
3Execute the following command to reboot the server.
# touch /reconfigure
# /usr/sbin/shutdown -y -g0 -i6
Do not set "max-throttle" for a multipath connection.
Chapter 7 Setting Up the Server
7.2 For Fujitsu's 3Gbit/s SAS Cards
15
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 8
Installing the Multipath Driver
8.1 For ETERNUS Multipath Driver
Refer to the documentation supplied with the product for installation details.
8.2 For MPxIO
Driver is bundled with OS. Installation is not necessary.
16
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 9
Setting the Multipaths
9.1 For ETERNUS Multipath Driver
Refer to the documentation supplied with the product for driver setup details.
9.2 For MPxIO
Fujitsu's 3Gbit/s SAS cards do not support MPxIO.
9.2.1 For 12Gbit/s SAS Cards
Setting up multipathing is not required because it is enabled by default.
Refer to "Sun StorEdge Traffic Manager Installation and Configuration Guide" on the Oracle web-site (http://
www.oracle.com/) for details about how to disable the multipath function for a specific SAS device.
Execute the following command to switch from single-path configuration to multipath configuration when a
single-path connection is used.
# stmsboot -D lsc -e
WARNING: This operation will require a reboot.
Do you want to continue ? [y/n] (default: y) (1)
updating /platform/i86pc/boot_archive
updating /platform/i86pc/amd64/boot_archive
The changes will come into effect after rebooting the system.
Reboot the system now ? [y/n] (default: y) (2)
Press the [Enter] key for (1) and (2).
17
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
9.2.2 For 6Gbit/s SAS Cards
Setting up multipathing is not required because it is enabled by default.
Refer to "Sun StorEdge Traffic Manager Installation and Configuration Guide" on the Oracle web-site (http://
www.oracle.com/) for details about how to disable the multipath function for a specific SAS device.
Execute the following command to switch from single-path configuration to multipath configuration when a
single-path connection is used.
# stmsboot -D mpt_sas -e
WARNING: This operation will require a reboot.
Do you want to continue ? [y/n] (default: y) (1)
The changes will come into effect after rebooting the system.
Reboot the system now ? [y/n] (default: y) (2)
updating /platform/sun4v/boot_archive
Press the [Enter] key for (1) and (2).
9.2.3 For 3Gbit/s SAS Cards
Execute the following command to enable multipathing.
Multipathing is set up for all of the SAS devices that are controlled by the mpt driver.
Refer to "Sun StorEdge Traffic Manager Installation and Configuration Guide" on the Oracle web-site (http://
www.oracle.com/) for details about how to disable the multipath function for a specific SAS device.
# stmsboot -D mpt -e
WARNING: This operation will require a reboot.
Do you want to continue ? [y/n] (default: y) (1)
The changes will come into effect after rebooting the system.
Reboot the system now ? [y/n] (default: y) (2)
updating /platform/sun4v/boot_archive
Press the [Enter] key for (1) and (2).
Chapter 9 Setting the Multipaths
9.2 For MPxIO
18
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
Chapter 10
ETERNUS DX Boot using a SAS Card
When using an ETERNUS DX LUN (Logical Unit) as the boot disk, check the "Server Support Matrix" for the
server environment being used, as well as any SAN boot documentation (such as in a system installation
guide) provided with the server.
When an ETERNUS DX LUN is to be used as a boot disk, it must be provided with sufficient capacity to install
the OS.
19
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Oracle Solaris
Copyright 2015 FUJITSU LIMITED
P3AM-3452-13ENZ0
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
(SAS) for Oracle Solaris
P3AM-3452-13ENZ0
Date of issuance: June 2015
Issuance responsibility: FUJITSU LIMITED
The content of this manual is subject to change without notice.
This manual was prepared with the utmost attention to detail. However, Fujitsu shall assume no responsibility for any
operational problems as the result of errors, omissions, or the use of information in this manual.
Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information
in this manual.
The content of this manual may not be reproduced or distributed in part or in its entirety without prior permission from
Fujitsu.
/