Fujitsu FTS:ETED6HB-L Datasheet

Category
Internal hard drives
Type
Datasheet
This page is intentionally left blank.
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
3
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
Preface
Fujitsu would like to thank you for purchasing our ETERNUS DX60 S2 Disk storage system.
The ETERNUS DX60 S2 Disk storage system is designed to be connected to a Fujitsu
(PRIMEQUEST or PRIMERGY) or non-Fujitsu servers.
This guide describes operation management and maintenance for the ETERNUS DX60 S2 Disk
storage system.
This guide is intended for use of ETERNUS DX60 S2 Disk storage system in regions other than
Japan.
Please carefully review the information outlined in this manual.
Second Edition
September 2011
Microsoft, Windows and Windows Server are either registered trademarks or trademarks of
Microsoft Corporation in the United States and/or other countries.
The company names, product names and service names mentioned in this document are
registered trademarks or trademarks of their respective companies.
Screen shot(s) reprinted with permission from Microsoft Corporation.
Copyright 2011 FUJITSU LIMITED
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
4
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
About this Manual
Organization
This document is composed of the following seven chapters and an appendix:
Chapter 1 Components
This chapter describes the components of the ETERNUS DX60 S2 Disk storage system.
Chapter 2 Standard Operations
This chapter explains how to turn on and off the ETERNUS DX60 S2 Disk storage system
and how to operate the buttons on the operation panel.
Chapter 3 Setup
This chapter describes the required settings and notes for operation of the ETERNUS DX60
S2 Disk storage system.
Chapter 4 Operations
This chapter describes the LAN for operation management of the ETERNUS DX60 S2 Disk
storage system and explains how to monitor the status of the ETERNUS DX60 S2 Disk
storage system.
Chapter 5 Installing Optional Products
This chapter describes how to install optional products.
Chapter 6 Maintenance
This chapter describes maintenance for the ETERNUS DX60 S2 Disk storage system.
Chapter 7 Troubleshooting
This chapter explains troubleshooting when errors occur in the ETERNUS DX60 S2 Disk
storage system.
"Event Notification Message List" is described as an appendix.
About this Manual
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
5
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
Warning Notations
Warning signs are shown throughout this manual in order to prevent injury to the user and/or
material damage. These signs are composed of a symbol and a message describing the
recommended level of caution. The following explains the symbols, their levels of caution, and
their meanings as used in this manual.
The following symbols are used to indicate the type of warnings or cautions being described.
WARNING
This symbol indicates the possibility of serious or fatal injury if the
ETERNUS DX60 S2 Disk storage system is not used properly.
CAUTION
This symbol indicates the possibility of minor or moderate personal injury,
as well as damage to the ETERNUS DX60 S2 and/or to other users and
their property, if the ETERNUS DX60 S2 Disk storage system is not used
properly.
IMPORTANT
This symbol indicates IMPORTANT information for the user to note when
using the ETERNUS DX60 S2 Disk storage system.
Electric Shock
The triangle emphasizes the urgency of the WARNING and
CAUTION contents. Inside the triangle and above it are details concerning
the symbol (e.g. Electrical Shock).
No Disassembly
The barred "Do Not..." circle warns against certain actions. The
action which must be avoided is both illustrated inside the barred circle
and written above it (e.g. No Disassembly).
Unplug
The black "Must Do..." disk indicates actions that must be taken. The
required action is both illustrated inside the black disk and written above it
(e.g. Unplug).
About this Manual
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
6
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
How Warnings are Presented in this Manual
A message is written beside the symbol indicating the caution level. This message is marked
with a vertical ribbon in the left margin, to distinguish this warning from ordinary descriptions.
An example is shown here.
Additional Information
Symbols Used in This Manual
The following is an expression used throughout this manual:
Abbreviations Used in This Manual
"ETERNUS DX Disk storage system" refers to the ETERNUS DX60 S2 Disk storage system.
"Host Bus Adapter (HBA)" refers to the interface module normally used by the server to
connect to the ETERNUS DX Disk storage systems.
"Interface module" may be referred to as "FC card", "LAN card", "Network Interface Card
(NIC)", or "SAS card", depending on the type of server and interface that are used.
Trademark symbols such as ™ and ® are omitted in this document.
Warning Level Indicator
Warning Type Indicator
Warning Details
To avoid damaging the ETERNUS DX60 S2 Disk storage system,
pay attention to the following points when cleaning
the ETERNUS DX60 S2 Disk storage system:
- Make sure to disconnect the power when cleaning.
- Be careful that no liquid seeps into the ETERNUS DX60 S2
Disk storage system when using cleaners, etc.
- Do not use alcohol or other solvents to clean
the ETERNUS DX60 S2 Disk storage system.
Warning Layout Ribbon
Example Warning
Functions and know how which can be useful when setting up or operating
the ETERNUS DX60 S2 Disk storage system.
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
7
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
Table of Contents
Chapter 1 Components ...........................................................................11
1.1 Controller Enclosure ......................................................................................... 11
1.1.1 Front .......................................................................................................................................... 11
1.1.2 Rear ........................................................................................................................................... 12
1.1.3 Components (Front) .................................................................................................................. 12
1.1.4 Components (Rear) ................................................................................................................... 16
1.2 Drive Enclosures .............................................................................................. 22
1.2.1 Front .......................................................................................................................................... 22
1.2.2 Rear ........................................................................................................................................... 23
1.2.3 Components (Front) .................................................................................................................. 23
1.2.4 Components (Rear) ................................................................................................................... 25
1.3 Power Distribution Units (for Regions other than EMEA&I) ............................. 27
1.3.1 Power Distribution Units (1U) .................................................................................................... 27
1.3.2 Power Distribution Units (2U) .................................................................................................... 28
Chapter 2 Standard Operations..............................................................29
2.1 Powering On and Off ........................................................................................ 29
2.1.1 Switching On and Off the Main Line Switch on the Power Distribution Unit
(for Regions Other than EMEA&I) ............................................................................................. 29
2.1.2 Powering On .............................................................................................................................. 31
2.1.3 Powering Off .............................................................................................................................. 33
2.2 Attaching and Removing the Flange Cover ..................................................... 34
2.3 Attaching and Removing the Front Cover ........................................................ 36
2.4 Turning On and Off the AUTO POWER Switch ............................................... 38
2.5 Using the IP RESET Switch ............................................................................. 40
Chapter 3 Setup .......................................................................................42
3.1 Data Encryption ................................................................................................ 42
3.2 Eco-mode ......................................................................................................... 42
3.3 Data Management ............................................................................................ 45
3.3.1 RAID Migration .......................................................................................................................... 46
3.3.2 Logical Device Expansion (LDE) ............................................................................................... 46
3.3.3 LUN Concatenation ................................................................................................................... 47
Chapter 4 Operations ..............................................................................49
4.1 LAN for Operation Management ...................................................................... 49
4.2 Monitoring ETERNUS DX Disk Storage System Status .................................. 50
4.2.1 LED Status Check ..................................................................................................................... 51
Table of Contents
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
8
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
4.2.2 Displaying Status via ETERNUS Web GUI ............................................................................... 51
4.2.3 Event Notification ....................................................................................................................... 52
Chapter 5 Installing Optional Products .................................................54
5.1 Installing Disks ................................................................................................. 54
5.1.1 Installation Rules for Disks ........................................................................................................ 55
5.1.2 Installable Disks ......................................................................................................................... 56
5.1.3 Disk Handling Instructions ......................................................................................................... 57
5.1.4 Additional Disk Installation Procedure ....................................................................................... 59
5.2 Installing Drive Enclosures ............................................................................... 63
5.2.1 Installation Rules for Drive Enclosures ...................................................................................... 63
5.2.2 Installable Drive Enclosures ...................................................................................................... 63
5.2.3 Drive Enclosure Handling Instructions ....................................................................................... 64
5.2.4 Drive Enclosure Rack Installation Procedure ............................................................................ 65
5.2.5 Additional Drive Enclosure Installation ...................................................................................... 70
Chapter 6 Maintenance............................................................................76
6.1 Periodic Backup ............................................................................................... 76
6.2 Volume Formatting Time .................................................................................. 76
6.3 Rebuild/Copyback Process Time ..................................................................... 77
6.4 Maintenance Service ........................................................................................ 78
6.4.1 Maintenance Support Period ..................................................................................................... 78
6.4.2 Related Service ......................................................................................................................... 78
Chapter 7 Troubleshooting .....................................................................79
7.1 Check List ........................................................................................................ 79
7.2 Required Information for Inquiries .................................................................... 84
Appendix A Event Notification Message List ...........................................86
A.1 Message Format ............................................................................................... 86
A.1.1 E-Mail ........................................................................................................................................ 87
A.1.2 SNMP ........................................................................................................................................ 89
A.1.3 Host Sense ................................................................................................................................ 91
A.2 Message List ..................................................................................................... 92
A.2.1 Common Terms......................................................................................................................... 92
A.2.2 Error Messages ......................................................................................................................... 93
A.2.3 Warning Messages.................................................................................................................. 101
A.2.4 Informational Messages .......................................................................................................... 106
A.2.5 Test Messages ........................................................................................................................ 115
A.2.6 Sense Codes ........................................................................................................................... 115
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
9
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
List of Figures
Figure 1.1 Front view of a 2.5" type controller enclosure............................................................................ 11
Figure 1.2 Front view of a 3.5" type controller enclosure (with front cover)................................................ 11
Figure 1.3 Front view of a 3.5" type controller enclosure (without front cover)........................................... 11
Figure 1.4 Rear view of a controller enclosure (single controller type)....................................................... 12
Figure 1.5 Rear view of a controller enclosure (dual controller type) ......................................................... 12
Figure 1.6 Operation panel (2.5" type controller enclosure) ....................................................................... 13
Figure 1.7 Operation panel (3.5" type controller enclosure) ....................................................................... 13
Figure 1.8 2.5" type disk ............................................................................................................................. 14
Figure 1.9 Disk slot numbers (2.5" type controller enclosure) .................................................................... 14
Figure 1.10 3.5" type disk ............................................................................................................................. 15
Figure 1.11 Disk slot numbers (3.5" type controller enclosure) .................................................................... 15
Figure 1.12 Controller (FC model) ................................................................................................................ 16
Figure 1.13 Controller (iSCSI model)............................................................................................................ 18
Figure 1.14 Controller (SAS model).............................................................................................................. 20
Figure 1.15 Power supply unit ...................................................................................................................... 21
Figure 1.16 Front view of a drive enclosure (with front cover)...................................................................... 22
Figure 1.17 Front view of a drive enclosure (without front cover)................................................................. 22
Figure 1.18 Rear view of drive enclosure (single expander model).............................................................. 23
Figure 1.19 Rear view of drive enclosure (dual expander model) ................................................................ 23
Figure 1.20 LEDs on the front side of the drive enclosure............................................................................ 23
Figure 1.21 3.5" disk ..................................................................................................................................... 24
Figure 1.22 Disk slot numbers (drive enclosure) .......................................................................................... 24
Figure 1.23 Expander ................................................................................................................................... 25
Figure 1.24 Power supply units .................................................................................................................... 26
Figure 1.25 Power distribution unit (1U) ....................................................................................................... 27
Figure 1.26 Power Distribution Units (2U, Max 6 enclosures connection).................................................... 28
Figure 1.27 Power Distribution Units (2U, Max 8 enclosures connection).................................................... 28
Figure 2.1 ON position (marked "|") of the main line switches on a 1U power distribution unit .................. 29
Figure 2.2 ON position (marked "|") of the main line switches on a 2U power distribution unit .................. 30
Figure 2.3 OFF position (marked "O") of the main line switches on a 1U power distribution unit .............. 30
Figure 2.4 OFF position (marked "O") of the main line switches on a 2U power distribution unit .............. 31
Figure 4.1 LAN control (switching of the Master CM) ................................................................................. 49
Figure 4.2 LAN control (when the IP address of the Slave CM is set)........................................................ 50
Figure 4.3 ETERNUS Web GUI screen...................................................................................................... 51
Figure 4.4 Event notification ....................................................................................................................... 53
Figure 5.1 Position of 2.5" disk slots........................................................................................................... 55
Figure 5.2 Position of 3.5" disk slots........................................................................................................... 55
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
10
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
List of Tables
Table 1.1 Status and meanings of each LED (operation panel (controller enclosure)) ............................. 14
Table 1.2 Status and meanings of each LED (2.5" disks) ......................................................................... 15
Table 1.3 Status and meanings of each LED (3.5" disks) ......................................................................... 16
Table 1.4 Status and meanings of each LED (FC model controller) ......................................................... 17
Table 1.5 Status and meanings of each LED (iSCSI model controller)..................................................... 19
Table 1.6 Status and meanings of each LED (SAS model controller)....................................................... 20
Table 1.7 Status and meanings of each LED (power supply unit)............................................................. 22
Table 1.8 Status and meanings of each LED (in front of drive enclosure) ................................................ 24
Table 1.9 Status and meanings of each LED (3.5" disks) ......................................................................... 25
Table 1.10 Status and meanings of each LED (expander).......................................................................... 26
Table 1.11 Status and meanings of each LED (power supply unit)............................................................. 26
Table 4.1 General status of ETERNUS Web GUI ..................................................................................... 52
Table 5.1 Installable disks (2.5" disks) ...................................................................................................... 56
Table 5.2 Installable disks (3.5" disks) ...................................................................................................... 56
Table 5.3 Installable drive enclosures ....................................................................................................... 63
Table 6.1 Time for volume formatting (disk) .............................................................................................. 76
Table 6.2 Rebuild process time (disk) ....................................................................................................... 77
Table 6.3 Copyback process time (disk) ................................................................................................... 77
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
11
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
Chapter 1 Components
This chapter describes the components of the ETERNUS DX Disk storage system.
1.1 Controller Enclosure
An operation panel and disks are installed in the front of the controller enclosure. Controllers and
power supply units are installed in the rear.
1.1.1 Front
2.5" type
Figure 1.1 Front view of a 2.5" type controller enclosure
3.5" type
With front cover
Figure 1.2 Front view of a 3.5" type controller enclosure (with front cover)
Without front cover
Figure 1.3 Front view of a 3.5" type controller enclosure (without front cover)
Flange cover
Operation panel
2.5-inch disk
Front cover
Operation panel
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
12
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
1.1.2 Rear
Single controller type
Figure 1.4 Rear view of a controller enclosure (single controller type)
Dual controller type
Figure 1.5 Rear view of a controller enclosure (dual controller type)
1.1.3 Components (Front)
This section describes the operation panel and the disks in the front of the controller enclosure.
Operation panel
An operation panel has LEDs, a power switch, an AUTO POWER switch, a MODE SELECT
switch, and an IP RESET switch.
Controller (CM#0)
Cover
Power Supply Unit
(PSU#0)
Power Supply Unit
(PSU#1)
Controller (CM#0)
Power Supply Unit
(PSU#0)
Controller (CM#1)
Power Supply Unit
(PSU#1)
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
13
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
2.5" type
Figure 1.6 Operation panel (2.5" type controller enclosure)
3.5" type
Figure 1.7 Operation panel (3.5" type controller enclosure)
Part explanation
Power switch
This switch is used to turn on or off the ETERNUS DX Disk storage system.
AUTO POWER switch
Enables the AC Auto-Link Mode (This function automatically turns on the linked device once
AC power is supplied).
The Auto Power function is disabled for the factory default setting.
MODE SELECT switch
Enables the device power to be turned on via power linkage.
The MODE SELECT switch is enabled for the factory default setting. Do not change to OFF.
With a flange cover Without a flange cover
AUTO POWER switch
IP RESET switch
MODE SELECT switch
Power switch
CACHE LED
POWER LED
READY LED
FAULT LED
IDENTIFY LED
With a front cover Without a front cover
AUTO POWER switch
IP RESET switch
MODE SELECT switch
POWER LED
FAULT LED
CACHE LED
Power switch
READY LED
IDENTIFY LED
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
14
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
IP RESET switch
Click once to switch the Master CM LAN port from the current controller to the other controller.
Click twice in succession within a two second interval to revert the LAN port settings of the
ETERNUS DX Disk storage system to their factory settings.
LEDs
The states of LEDs are listed below.
Table 1.1 Status and meanings of each LED (operation panel (controller enclosure))
Disk
For 2.5" Disk
Figure 1.8 2.5" type disk
Figure 1.9
shows the slot number of each disk.
Figure 1.9 Disk slot numbers (2.5" type controller enclosure)
LED name LED status ETERNUS DX Disk storage system status
POWER
(green)
DC power is supplied to the controller enclosure.
READY
(green)
The ETERNUS DX Disk storage system is available for
use.
FAULT
(orange)
The ETERNUS DX Disk storage system is in error
status.
(blinks orange)
A part of the ETERNUS DX Disk storage system
requires preventive maintenance.
IDENTIFY
(blinks blue)
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
CACHE
(green)
There is data in the ETERNUS DX Disk storage system
cache memory.
(blinks green)
Data in the cache memory is saved to a non-volatile
memory.
DISK FAULT LEDDISK READY LED
Slot#8
Slot#9
Slot#10
Slot#11
Slot#12
Slot#13
Slot#14
Slot#15
Slot#0
Slot#1
Slot#2
Slot#3
Slot#4
Slot#5
Slot#6
Slot#7
Slot#16
Slot#17
Slot#18
Slot#19
Slot#20
Slot#21
Slot#22
Slot#23
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
15
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
Part explanation
LEDs
The states of LEDs are listed below.
Table 1.2 Status and meanings of each LED (2.5" disks)
For 3.5" Disks
Figure 1.10 3.5" type disk
Figure 1.11
shows the slot number of each disk.
Figure 1.11 Disk slot numbers (3.5" type controller enclosure)
WARNING
Do Not
System disks are installed in Slot#0 and Slot#1. Never remove
system disks. Doing so will render the ETERNUS DX Disk storage
system unusable.
LED name LED status Disk status
DISK READY
(green)
The disk is operating normally.
(blinks green)
DISK FAULT
(orange)
The disk is in error status.
(blinks orange)
In response to commands from Microsoft Virtual Disk
Service (VDS), the location of the disk is identified.
WARNING
Do Not
System disks are installed in Slot#0 and Slot#1. Never remove
system disks. Doing so will render the ETERNUS DX Disk storage
system unusable.
DISK READY/FAULT LED
Slot#0
Slot#4
Slot#8
Slot#1
Slot#5
Slot#9
Slot#2
Slot#6
Slot#10
Slot#3
Slot#7
Slot#11
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
16
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
Part explanation
LEDs
The states of LEDs are listed below.
Table 1.3 Status and meanings of each LED (3.5" disks)
1.1.4 Components (Rear)
This section describes the controllers and the power supply units in the rear of the controller
enclosure.
1.1.4.1 Controllers
The controller contains a CPU, cache memory, System Capacitor Unit (SCU), non-volatile mem-
ory, host interface adapters, drive interface (DI) ports, and LAN ports.
The controller controls all operations in the ETERNUS DX Disk storage system.
FC model
Figure 1.12 Controller (FC model)
LED name LED status Disk status
DISK READY/
FAULT
(green)
The disk is operating normally.
(blinks green)
(orange)
The disk is in error status.
(blinks orange)
In response to commands from Microsoft Virtual Disk
Service (VDS), the location of the disk is identified.
FC LINKUP/FAULT LED
FC port (0 (Left), 1 (Right))
DI (OUT) port
LAN (RMT) port
PWC port
DI (OUT) LINKUP LED
MASTER LED
ACT LED
LINK LED
SCU STATUS LED
UNIT READY/FAULT LED
IDENTIFY LED
LAN (MNT) port
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
17
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
Part explanation
LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
FC port (0 (left), 1 (right))
These are the Dual LC connectors to connect FC cables.
PWC port
This port is not used.
DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a miniSAS cable.
LEDs
The states of LEDs are listed below.
Table 1.4 Status and meanings of each LED (FC model controller)
LED name LED status Controller status
SCU STATUS
(green)
The SCU is in normal status.
(blinks green)
SCU is charging.
IDENTIFY
(blinks blue)
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
(off)
DI (OUT) LINKUP
(green)
The link between the DI (OUT) port and the destination
has been established.
FC LINKUP/
FAULT
(green)
The link between the FC port (host interface port) and
the destination has been established.
(orange)
The FC port (host interface port) is in error status.
UNIT READY/
FAULT
(green)
The controller is in normal status.
(orange)
The controller is performing the initial setup after the
power is turned on.
The controller is in error status.
MASTER
(green)
The controller is set as a Master CM.
ACT
(green)
The controller is sending or receiving data via the LAN
port (for operation management).
LINK
(green)
The link between the LAN port (for operation
management) and the destination has been
established.
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
18
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
iSCSI model
Figure 1.13 Controller (iSCSI model)
Part explanation
LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
iSCSI port (0 (left), 1 (right))
These ports are RJ45 connectors for LAN cables.
PWC port
This port is not used.
DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a miniSAS cable.
DI (OUT) port
PWC port
MASTER LED
ACT LED
LINK LED
UNIT READY/FAULT LED
iSCSI port (0 (Left), 1 (Right))
FAULT LED
LINK LED
LAN (RMT) port
DI (OUT) LINKUP LED
SCU STATUS LED
IDENTIFY LED
LAN (MNT) port
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
19
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
LEDs
The states of LEDs are listed below.
Table 1.5 Status and meanings of each LED (iSCSI model controller)
LED name LED status Controller status
SCU STATUS
(green)
The SCU is in normal status.
(blinks green)
SCU is charging.
IDENTIFY
(blinks blue)
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
(off)
DI (OUT) LINKUP
(green)
The link between the DI (OUT) port and the destination
has been established.
UNIT READY/
FAULT
(green)
The controller is in normal status.
(orange)
The controller is performing the initial setup after the
power is turned on.
The controller is in error status.
MASTER
(green)
The controller is set as a Master CM.
ACT
(green)
The controller is sending or receiving data via the LAN
port (for operation management).
LINK
(green)
The link between the LAN port (for operation
management) and the destination has been
established.
The link between the iSCSI port (host interface port)
and the destination has been established.
FAULT
(orange)
The controller is performing the initial setup after the
power is turned on.
The iSCSI port (host interface port) is in error status.
Chapter 1 Components
1.1 Controller Enclosure
ETERNUS DX60 S2 Disk storage system User’s Guide -Operation-
20
Copyright 2011 FUJITSU LIMITED P3AM-5512-02ENZ0
SAS model
Figure 1.14 Controller (SAS model)
Part explanation
LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
SAS port (0 (left), 1 (right))
These are the miniSAS (SFF8088) connectors to connect miniSAS cables.
PWC port
This port is not used.
DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a miniSAS cable.
LEDs
The states of LEDs are listed below.
Table 1.6 Status and meanings of each LED (SAS model controller)
LED name LED status Controller status
SCU STATUS
(green)
The SCU is in normal status.
(blinks green)
SCU is charging.
IDENTIFY
(blinks blue)
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
(off)
DI (OUT) LINKUP
(green)
The link between the DI (OUT) port and the destination
has been established.
SAS port (0 (Left), 1 (Right))
SAS (HOST) LINKUP/FAULT LED
DI (OUT) port
PWC port
ACT LED
LINK LED
MASTER LED
UNIT READY/FAULT LED
LAN (RMT) port
DI (OUT) LINKUP LED
SCU STATUS LED
IDENTIFY LED
LAN (MNT) port
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119

Fujitsu FTS:ETED6HB-L Datasheet

Category
Internal hard drives
Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI