Von Duprin 6211 is an electric strike designed for single door aluminum frame mortise or cylindrical applications. It features fail-secure (FSE) and fail-safe (FS) operation, with the FSE lip unlocking when solenoid power is applied and the FS lip locking when power is removed. The strike has a static strength rating of 1500 lb., a dynamic strength rating of 70ft.-lb., and an endurance rating of 250,000 cycles. It is compatible with 12 VDC or 24 VDC power supplies and has a transient voltage suppressor (TVS) for added protection.

Von Duprin 6211 is an electric strike designed for single door aluminum frame mortise or cylindrical applications. It features fail-secure (FSE) and fail-safe (FS) operation, with the FSE lip unlocking when solenoid power is applied and the FS lip locking when power is removed. The strike has a static strength rating of 1500 lb., a dynamic strength rating of 70ft.-lb., and an endurance rating of 250,000 cycles. It is compatible with 12 VDC or 24 VDC power supplies and has a transient voltage suppressor (TVS) for added protection.

*931221-00*
931221-00
Electric Strike, Single Door Aluminum Frame Mortise or
Cylindrical Application
6211AL/6211ALDS
Installation Instructions
{
1
2
3
4
5
6
1
2
3
4
5
6
}
}
Notes: Deadbolt will not function with this strike.
Check with factory for retrofit applications.
1. For lock or device preparation, see their directions.
2. Prepare frame for strike (see other side).
3. Wire strike (Figure 1). (Switches on 6211ALDS only.)
4. Install insert for auxiliary bolt operation (Figure 2).
5. Test strike: Apply solenoid power. Fail secure (FSE)
lip unlocks. Fail safe (FS) lip locks. Figure 1 shows
status of switches.
6. Install strike with two #12-24 screws. Make sure clearance
between latch bolt and strike lip is 1/32" (Figure 3). If not,
uninstall strike, adjust (Figure 4), and reinstall.
7. If latch bolt does not extend far enough to actuate tripper,
install extension (Figure 5). (Tripper on 6211ALDS only.)
8. Test door: With strike unlocked, door opens with latch bolt
extended. When door closes, latch bolt rides over strike lip.
Yellow solenoid wires: 12 VDC, 0.57 A
Black solenoid wires: 24 VDC, 0.29 A
(also shown on strike label)
SOLENOID POWER REQUIREMENTS
{NOTE
DC input is
nonpolarized
!
Wiring
for DC
supply
12 VDC
or
24 VDC
Wiring
for AC
supply
Standard: 5 A, 30 VDC
Gold: 0.25 A, 30 VDC
SWITCH RATINGS
Use crimp
connectors to
splice field wiring
to P1 leads
Switches shown with tripper
depressed, strike lip closed and locked
(switches and tripper on 6211ALDS only)
Fail safe (FS) Fail secure (FSE)
Use crimp connectors to
splice field wiring to P2
leads; insulate unused leads
12 VAC
or
24 VAC
12 VDC
24 VDC
SO-12
SO-24
SO-12 or SO-24
Solenoid
P1 J1A P1A
J2 P2
P1
J1
Figure 1
Red (C)
Blue
Yellow
White (C)
Gray
Violet
S1
(monitors
tripper)
S2
(monitors
strike lip)
J2 J2 P2
S1 S1
S2 S2
A
D
B
C
Figure 2 Figure 3 Figure 4
Figure 5
89/336/EEC
NOTE:
Static Strength Rating 1500 lb.
Dynamic Strength Rating 70ft.-lb.
Endurance Rating 250,000 c.
To adjust strike, loosen screws
A, B, and C and move backbox
sideways as necessary
Top view;
faceplate not
shown for clarity
Alternate
insert
position
Fit hook on
insert into notch
on faceplate
Tripper
Extension
For more
adjustment,
move screw
A to hole D
Latch bolt
Strike lip
1/32"
TVS Installation Recommended
PS
12/24
VDC
Access Control
TVS
(Transient Voltage
Suppressor Included)
6211
Electric
Strike
Strike
backbox
assembly
1-21/32
minimum clearance
4-1/8
5/8
2” minimum
clearance
12minimum
clearance
C strike
L
1-1/4
11/32max.
3/8
4-1/83-3/8”
4-7/8
1-15/32
5/8
3/4
C lock and strike
L
C strike
L
Suggested
cutout
3/16rad.
4 places
#16 drill and #12-24 tap
2 places
Reinforce for strike
attachment as required
1-1/4
1-1/4
4-7/8
1-1/8
2-7/162-1/16”
3-3/8
1-11/16
1/86
Frame Preparation for Strike
Strike Dimensions and Required Clearances
LHR shown
RHR opposite
© Allegion 2016
Printed in U.S.A.
931221-00 Rev. 11/16-d
Customer Service
1-877-671-7011 www.allegion.com/us
  • Page 1 1
  • Page 2 2

Von Duprin 6211 Installation guide

Type
Installation guide

Von Duprin 6211 is an electric strike designed for single door aluminum frame mortise or cylindrical applications. It features fail-secure (FSE) and fail-safe (FS) operation, with the FSE lip unlocking when solenoid power is applied and the FS lip locking when power is removed. The strike has a static strength rating of 1500 lb., a dynamic strength rating of 70ft.-lb., and an endurance rating of 250,000 cycles. It is compatible with 12 VDC or 24 VDC power supplies and has a transient voltage suppressor (TVS) for added protection.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI