![](//vs1.manuzoid.com/store/data-gzf/b60947fdcd87197cc16231c9a4966c55/2/001991538.htmlex.zip/bg2.jpg)
Description
Reference
Designator
Volatility Description
User
Accessible
for external
data
Remedial Action
(Action necessary to
prevent loss of data)
will depend on SODIMM
modules and must be
between 4 GB and 32 GB
System
memory
SPD
EEPROM
On System
memory
SODIMM(s)
: 1-2 present
Non-Volatile memory 512
Bytes
Stores memory manufacturer
data and timing information
for correct operation of
system memory
No N/A
Panel
EEDID
EEPROM
Part of panel
assembly
Non-Volatile memory, 512
Bytes
No N/A, Part of panel assembly
Security
EEPROM
Security
Board,
U4701
Non-Volatile memory, 32Mbit
Application code for security
controller
No N/A
Hard
drive(s)
User
replaceable:
One present
Non Volatile magnetic media,
various sizes in GB. May also
be SSD (solid state flash
drive)
Yes
Low level format
PCMCIA
EEPROMs
PCMCIA
Board, U7,
U11
Non-Volatile memory, 2Kbit
Application code for PCMCIA
controllers
No N/A
2
nd
/3
rd
Drive
Controller
EEPROMs
2
nd
/3
rd
Drive
Storage
Option,
U0402,
U0502
Non-Volatile memory,
512Kbit
Application code for
drive controllers
No N/A
CD-
ROM/RW/
DVD/
DVD+RW/
Diskette
Drives
User
replaceable
Non-Volatile optical media Yes Low level format/erase
CAUTION: All other components on the system board lose data if power is removed from the
system. Primary power loss (unplugging the power cord and removing the battery) destroys all
user data on the memory (DDR4, 2400 MHz). Secondary power loss (removing the on-board coin-
cell battery) destroys system data on the system configuration and time-of-day information.
March 2021
Copyright © 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its
subsidiaries. Other trademarks may be trademarks of their respective owners.